Performance benchmarking of residential air conditioning systems using smart thermostat data

被引:2
|
作者
Guo, Fangzhou [1 ]
Rasmussen, Bryan [2 ]
机构
[1] Hong Kong Polytech Univ, Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[2] Texas A&M Univ, Mech Engn, College Stn, TX USA
关键词
Smart thermostat; Residential air conditioning system; Fault detection and diagnosis; Performance benchmarking; Refrigerant leakage; FAULT; DIAGNOSIS;
D O I
10.1016/j.applthermaleng.2023.120195
中图分类号
O414.1 [热力学];
学科分类号
摘要
Faulty residential Heating, Ventilation, and Air Conditioning (HVAC) systems waste billions of dollars of energy usage in the U.S. each year, meanwhile heavily affecting occupant comfort and causing complete operational failures. Fault detection and diagnosis (FDD) methods assist technicians in discovering and locating faults as early as possible, thereby optimizing system efficiency through predictive maintenance. However, the majority of FDD methods are developed for commercial HVAC systems. This is because FDD needs data acquired from sensors installed on the HVAC equipment, but in the residential sector, the initial cost of installing additional sensors is uneconomical. In recent years, the development of smart thermostats and the Internet of Things (IoT) enables large-scale system operational data to be recorded. The collection of smart thermostat data has nearly no cost, and FDD can be conducted using aggregated data obtained from a large number of systems using IoT technologies. Hence, this paper proposes a performance benchmarking method for residential systems that only use smart thermostats as the data source. The proposed method analyzes the system pseudo steady-state behavior and compares a critical feature termed the weighted average difference of cooling effort (Delta Ec) both between systems and within each system. Three applications of the proposed method are detailed: identification of inadequate capacity, quantification of active capacity degradation, and verification of repair after maintenance. Within each application, real faulty systems are illustrated to demonstrate the usefulness of this method.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] The solar contribution to air conditioning systems for residential buildings
    Sayegh, Marderos Ara
    DESALINATION, 2007, 209 (1-3) : 171 - 176
  • [22] Performance monitoring of air conditioning system using inconsistent data
    Ishii Y.
    IEEJ Transactions on Electronics, Information and Systems, 2016, 136 (09) : 1411 - 1417
  • [23] Effect of Compressor Discharge Cooling Using Condensate on Performance of Residential Air Conditioning System
    Sumeru, K.
    Sunardi, Cecep
    Sukri, M. F.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [24] Experimental investigation on the performance of residential air conditioning system using water condensate for subcooling
    Sumeru, Kasni
    Pramudantoro, Triaji Pangripto
    Setyawan, Andriyanto
    3RD ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2018), 2018, 197
  • [25] Comparative studies on using RSM and TOPSIS methods to optimize residential air conditioning systems
    Mao, Ning
    Song, Mengjie
    Pan, Dongmei
    Deng, Shiming
    ENERGY, 2018, 144 : 98 - 109
  • [26] Smart meter data-driven evaluation of operational demand response potential of residential air conditioning loads
    Qi, Ning
    Cheng, Lin
    Xu, Helin
    Wu, Kuihua
    Li, XuLiang
    Wang, Yanshuo
    Liu, Rui
    APPLIED ENERGY, 2020, 279
  • [27] Experimental performance analysis and modelling of liquid desiccant cooling systems for air conditioning in residential buildings
    Pietruschka, D
    Eicker, U
    Huber, M
    Schumacher, J
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (01): : 110 - 124
  • [28] Performance of residential air-conditioning systems with flow maldistribution in fin-and-tube evaporators
    Kaern, Martin Ryhl
    Brix, Wiebke
    Elmegaard, Brian
    Larsen, Lars Finn Sloth
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (03): : 696 - 706
  • [29] Nonintrusive disaggregation of residential air-conditioning loads from sub-hourly smart meter data
    Perez, Krystian X.
    Cole, Wesley J.
    Rhodes, Joshua D.
    Ondeck, Abigail
    Webber, Michael
    Baldea, Michael
    Edgar, Thomas F.
    ENERGY AND BUILDINGS, 2014, 81 : 316 - 325
  • [30] Smart thermostat data-driven US residential occupancy schedules and development of a US residential occupancy schedule simulator
    Jung, Wooyoung
    Wang, Zhe
    Hong, Tianzhen
    Jazizadeh, Farrokh
    BUILDING AND ENVIRONMENT, 2023, 243