The Efficiency of Gray-Level Ultrasound Histogram Analysis in Patients with Supraspinatus Tendinopathy

被引:0
|
作者
Nalbant, M. O. [1 ,2 ]
Inci, E. [1 ]
机构
[1] Univ Hlth Sci, Bakirkoy Dr Sadi Konuk Training & Res Hosp, Dept Radiol, Istanbul, Turkiye
[2] Univ Hlth Sci, Bakirkoy Dr Sadi Konuk Training & Res Hosp, Dept Radiol, Tevfik Saglam Cad, TR-34147 Istanbul, Turkiye
关键词
Gray-level histogram; magnetic resonance imaging; supraspinatus tendon; tendinopathy; ROTATOR CUFF TEARS; ECHOGENICITY; ULTRASONOGRAPHY; DIAGNOSIS;
D O I
10.4103/njcp.njcp_325_23
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Musculoskeletal ultrasonography is a viable substitute for magnetic resonance imaging (MRI) that offers advantages in terms of time efficiency and cost-effectiveness. The gray-level histogram is a tool used to depict the distribution of pixel gray levels that provide quantitative data.Aim: The objective of our research was to establish a threshold value for ultrasonography-measured supraspinatus tendon gray-level values by comparing patients with tendinopathy to those without.Materials and Methods: This study comprised a cohort of 271 individuals, consisting of 124 patients diagnosed with supraspinatus tendinopathy and 147 cases without the aforementioned condition who underwent shoulder MRI and ultrasound examinations. Two radiologists independently conducted the gray-level histogram analyses. The histogram parameters were determined, including the mean, minimum, median, maximum, fifth, 10th, 25th, 50th, 75th, 90th, and 95th percentiles, as well as skewness, kurtosis, and variance. The interobserver agreement was evaluated using the interclass correlation coefficient.Results: The supraspinatus tendinopathy group's all gray-level values were lower than those of the control group, and the difference was statistically significant (P < .05). The supraspinatus tendinopathy group exhibited greater values of skewness and kurtosis in comparison to the control group (P < .05). The area under the curve of the 95th percentile of the gray-level value was the highest (area under the curve = 0.960; cut-off value = 82.5; sensitivity = 96.7%; specificity = 88.2%).Conclusion: The analysis of the histogram of gray-level values has the potential to be a promising method for the monitoring of patients with supraspinatus tendinopathy. This approach could be considered a feasible alternative to MRI.
引用
收藏
页码:1709 / 1715
页数:7
相关论文
共 50 条
  • [21] Segmentation of text and graphics/images using the gray-level histogram Fourier transform
    Patricio, MA
    Maravall, D
    ADVANCES IN PATTERN RECOGNITION, 2000, 1876 : 757 - 766
  • [22] NEW METHOD FOR GRAY-LEVEL PICTURE THRESHOLDING USING THE ENTROPY OF THE HISTOGRAM.
    Kapur, J.N.
    Sahoo, P.K.
    Wong, A.K.C.
    1600, (29):
  • [23] A novel gray-level registration algorithm for DSA image based on subtraction histogram
    Chu, Y.
    Ji, Z.
    Chen, S. P.
    Mou, X. Q.
    TENCON 2006 - 2006 IEEE REGION 10 CONFERENCE, VOLS 1-4, 2006, : 16 - +
  • [24] GRAY-LEVEL MANIPULATION EXPERIMENTS FOR TEXTURE ANALYSIS
    TROY, EB
    DEUTSCH, ES
    ROSENFELD, A
    IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1973, SMC3 (01): : 91 - 98
  • [25] SEMIAUTOMATED BOUNDARY DETECTION IN SPECT USING GRAY-LEVEL HISTOGRAM METHOD ON SCATTER IMAGE
    GIAP, HB
    MACEY, DJ
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P196 - P196
  • [26] MRI intensity nonuniformity correction using simultaneously spatial and gray-level histogram information
    Milles, Julien
    Zhu, Yue Min
    Gimenez, Gerard
    Guttmann, Charles R. G.
    Magnin, Isabelle E.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 81 - 90
  • [27] MRI intensity nonuniformity correction using simultaneously spatial and gray-level histogram information
    Milles, J
    Zhu, YM
    Chen, NK
    Panych, LR
    Gimenez, G
    Guttmann, CRG
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 734 - 742
  • [28] Pattern recognition in gray-level images by Fourier analysis
    Fonga, H
    PATTERN RECOGNITION LETTERS, 1996, 17 (14) : 1477 - 1489
  • [29] Gray-level thresholding method based on Fisher linear discriminant of two-dimensional histogram
    Gong, Jian
    Li, Liyuan
    Chen, Weinan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 18 (05): : 1 - 8
  • [30] Gray-level image thresholding based on Fisher linear projection of two-dimensional histogram
    Li, LY
    Gong, J
    Chen, WN
    PATTERN RECOGNITION, 1997, 30 (05) : 743 - 749