Slowly absorbable mesh in sublay ventral hernia repair in contaminated fields

被引:1
|
作者
Rodriguez-Quintero, Jorge Humberto [1 ]
Romero-Velez, Gustavo [2 ]
Mandujano, Camilo [1 ]
Huang, Li-Ching [3 ]
Sreeramoju, Prashanth [1 ]
Malcher, Flavio [4 ]
机构
[1] Montefiore Med Ctr, Dept Surg, Bronx, NY USA
[2] Cleveland Clin, Dept Endocrine Surg, Cleveland, OH USA
[3] Vanderbilt Univ, Ctr Quantitat Sci, Nashville, TN USA
[4] NYU, Dept Surg, 530 1st Ave, New York, NY 10016 USA
关键词
Permanent mesh; Slowly absorbable mesh; Contaminated surgical wounds; Outcomes; RESORBABLE BIOSYNTHETIC MESH; PATIENT PERCEPTIONS; MULTICENTER; IMPLEMENTATION; COMPLICATIONS; PHASIX(TM); OUTCOMES; SURGERY;
D O I
10.1007/s00464-023-10362-w
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background In the past years, there has been increasing evidence that supports the use of permanent mesh in contaminated wounds. Given this increased evidence, the indications to opt for slowly absorbable "biosynthetic" prostheses have been questioned. To address this, we compared the outcomes of slowly absorbable mesh in contaminated cases in a well-matched multicentric cohort. Methods The Abdominal Core Health Quality Collaborative (ACHQC) database was queried for patients undergoing elective ventral hernia repair in Centers for Disease Control (CDC)-III operations (2013-2022). We compared demographics, hernia characteristics, and postoperative outcomes among types of mesh. We used propensity score matching to adjust for sex, diabetes, body mass index, smoking status, and operative time between mesh groups. Patients within other CDC classes and those with mesh positioned elsewhere than retro-rectus/preperitoneal space were excluded. Results A total of 760 patients were included in the analysis. Slowly absorbable synthetic mesh (SA) was utilized in only 7% of the cases, while permanent (P) and biologic (B) mesh in 77% and 16%, respectively. After matching, 255 patients were studied. There was no difference in surgical site occurrence (8% SA, 16% P, 10% B, p = 0.27), surgical site infection (20% SA, 17% P, 12% B p = 0.54), surgical site occurrence requiring intervention (18% SA, 13% P, 14% B p = 0.72), readmission (12% SA, 14% P, 12% B, p = 0.90), or reoperation (8% SA, 2% P, 4% B, p = 0.14) at 30 days. In patients with 1-year follow-up, there was no difference in recurrence among groups (20% SA, 26% P, 24% B p = 0.90). Conclusion Based on our findings, SA has comparable outcomes to other types of mesh, particularly when an optimal retrorectus repair is performed.
引用
收藏
页码:8080 / 8090
页数:11
相关论文
共 50 条
  • [41] Laparoendoscopic stapled rives stoppa sublay technique for extraperitoneal ventral hernia repair
    Nguyen, David K.
    Chen, David C.
    EUROPEAN SURGERY-ACTA CHIRURGICA AUSTRIACA, 2017, 49 (04): : 175 - 179
  • [42] Comparative analysis of efficacy and quality of life between totally extraperitoneal sublay and intraperitoneal onlay mesh repair for ventral hernia
    Wang, Miaofeng
    Chen, Wei
    Chu, Xiufeng
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [43] Is the sublay self-gripping mesh effective for incisional ventral hernia repair? Our experience and a systematic review of the literature
    Schembari, Elena
    Sofia, Maria
    Lombardo, Rosario
    Randazzo, Valentina
    Coco, Ornella
    Mattone, Edoardo
    La Greca, Gaetano
    Russello, Domenico
    Latteri, Saverio
    UPDATES IN SURGERY, 2020, 72 (04) : 1195 - 1200
  • [44] Endoscopic preaponeurotic access for complex ventral hernia repair with sublay mesh and bilateral anterior component separation: A case report
    Cuccomarino, Salvatore
    Bonomo, Luca Domenico
    Romoli, Silvia Rosa
    Jannaci, Alberto
    ANNALS OF MEDICINE AND SURGERY, 2020, 60 : 241 - 244
  • [45] Comparative Study of Inlay Versus Sublay Mesh Repair in Paraumbilical Hernia
    Memon, Samar
    Haider, Shahzad Asfandyar
    Laghari, Muhammad Saleem
    Rasool, Bilal
    Laghari, Mujeeburehman
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (04): : 1457 - 1459
  • [46] Ventral hernia repair in high-risk patients and contaminated fields using a single mesh: proportional meta-analysis
    Morales-Conde, S.
    Hernandez-Granados, P.
    Tallon-Aguilar, L.
    Verdaguer-Tremolosa, M.
    Lopez-Cano, M.
    HERNIA, 2022, 26 (06) : 1459 - 1471
  • [47] Ventral hernia repair in high-risk patients and contaminated fields using a single mesh: proportional meta-analysis
    S. Morales-Conde
    P. Hernández-Granados
    L. Tallón-Aguilar
    M. Verdaguer-Tremolosa
    M. López-Cano
    Hernia, 2022, 26 : 1459 - 1471
  • [48] Comparative study of onlay versus sublay mesh repair in the management of ventral hernias
    Dharmendra K. Shah
    Shreyansh J. Patel
    Shivani R. Chaudhary
    Nisarg R. Desai
    Updates in Surgery, 2023, 75 : 1991 - 1996
  • [49] MARLEX MESH IN GIANT VENTRAL HERNIA REPAIR
    KAUFMAN, M
    WEISSBERG, D
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1980, 16 (9-10): : 739 - 742
  • [50] Choice of mesh for laparoscopic ventral hernia repair
    Eriksen J.R.
    Gögenur I.
    Rosenberg J.
    Hernia, 2007, 11 (6) : 481 - 492