Effect of a portable light emitting diode device on wound healing in a rat model

被引:1
|
作者
Cha, Han Gyu [1 ]
Hur, Joon [2 ]
Pak, Changsik John [2 ]
Hong, Joon Pio [2 ]
Suh, Hyunsuk Peter [2 ,3 ]
机构
[1] Soonchunhyang Univ, Soonchunhyang Univ Bucheon Hosp, Coll Med, Dept Plast & Reconstruct Surg, Bucheon, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Plast Surg, Seoul, South Korea
[3] Univ Ulsan, Asan Med Ctr, Sch Med, Dept Plast Surg, 88 Olymp ro 43-gil, Seoul, South Korea
关键词
LED; light emitting diode; portable LED; wound healing; DOUBLE-BLIND; RED-LIGHT; PHOTODYNAMIC THERAPY; PHOTOBIOMODULATION; TRIAL; IRRADIATION; EFFICACY; PLACEBO; ENERGY; LASER;
D O I
10.1111/iwj.14335
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Light-emitting diode (LED) lights produce a variety of wavelengths that have demonstrable efficacy in therapeutic and aesthetic fields. However, a repetitive treatment regimen is required to produce treatment outcomes, which has created a need for portable LED devices. In this study, we aimed to develop a portable therapeutic LED device and investigate its healing effect on excisional wounds in a rat model. The 35 x 35 mm-sized LED device was used on a total of 30 rats with full-thickness wounds that were divided into two groups depending on radiation intensity (11.1 and 22.2 mW/cm(2) group). LED irradiation was performed every 24 h for 30 min, over 14 days, in direct contact with the wound. Percentage wound closure was measured by photographic quantification and was assessed histologically using haematoxylin and eosin (H&E) and Masson's Trichrome staining, and immunohistochemistry for Vascular endothelial growth factor (VEGF) and CD31. Percentage wound closure was significantly higher in 22.2 mW/cm(2) irradiated wounds than that in the control wounds on days 7 and 10. The area of collagen deposition was remarkably larger in 22.2 mW/cm(2) irradiated wounds than that in the control, with more horizontally organized fibres. CD31 immunostaining confirmed a significant increase in the number of microvessels in 22.2 mW/cm(2) irradiated wounds than that in the control wounds, although there was no difference in VEGF immunostaining. Our novel portable LED device accelerates wound healing in a rat model, raising the possibility that portable LED devices can combine convenience with accessibility to play an innovative role in wound dressing.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] RAT MODEL OF BURN WOUND HEALING: EFFECT OF BOTOX
    Hussein, I. Abdallah Hajj
    Balta, N. Dali
    Jurjus, R. A.
    Watfa, W.
    Gerges, A.
    Atiyeh, B.
    Pullar, C.
    Leone, A.
    Jurjus, A. R.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2012, 26 (03): : 389 - 400
  • [22] Light-Emitting Diode Irradiation Promotes Donor Site Wound Healing of the Free Gingival Graft
    Wang, Chen-Ying
    Tsai, Sheng-Chueh
    Yu, Min-Chen
    Lin, Yu-Fang
    Chen, Chih-Cheng
    Chang, Po-Chun
    JOURNAL OF PERIODONTOLOGY, 2015, 86 (05) : 674 - 681
  • [23] Optical design and optimization of light emitting diode automotive head light with digital micromirror device light emitting diode
    Huang, Ming-Shyan
    Hung, Chuan-Cheng
    Fang, Yi-Chin
    Lai, Wei-Chi
    Chen, Yi-Liang
    OPTIK, 2010, 121 (10): : 944 - 952
  • [24] A multi-source portable light emitting diode spectrofluorometer
    Obeidat, Safwan
    Bai, Baolong
    Rayson, Gary D.
    Anderson, Dean M.
    Puscheck, Adam D.
    Landau, Serge Y.
    Glasser, Tzach
    APPLIED SPECTROSCOPY, 2008, 62 (03) : 327 - 332
  • [25] A comparative study of the effects of laser and light-emitting diode irradiation on the wound healing and functional activity of wound exudate leukocytes
    Klebanov, GI
    Shuraeva, NY
    Chichuk, TV
    Osipov, AN
    Rudenko, TG
    Shekhter, AB
    Vladimirov, YA
    BIOFIZIKA, 2005, 50 (06): : 1137 - 1144
  • [26] LIGHT-EMITTING DIODE FOR USE AS A FIXATION DEVICE
    RUMELT, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1974, 78 (03) : 537 - 538
  • [27] Simulating the Device Characteristics of GaN Light Emitting Diode
    Cheng, Wen-Yu
    Cheng, Shiou-Ying
    PROCEEDINGS OF 2010 CROSS-STRAIT CONFERENCE ON INFORMATION SCIENCE AND TECHNOLOGY, 2010, : 797 - 799
  • [28] A Standardized Light-Emitting Diode Device for Photoimmunotherapy
    de Boer, Esther
    Warram, Jason M.
    Hartmans, Elmire
    Bremer, Peter J.
    Bijl, Ben
    Crane, Lucia M. A.
    Nagengast, Wouter B.
    Rosenthal, Eben L.
    van Dam, Gooitzen M.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (11) : 1893 - 1898
  • [29] Optimization of a classic oganic light emitting diode device
    Burson, Claire
    Bodenstedt, Kurt
    Li, Shan
    Omary, Mohammad
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [30] Effect of radiation and cell implantation on wound healing in a rat model
    Dantzer, D
    Ferguson, P
    Hill, RP
    Keating, A
    Kandel, RA
    Wunder, JS
    Ofsullivan, B
    Sandhu, J
    Waddell, J
    Bell, RS
    JOURNAL OF SURGICAL ONCOLOGY, 2003, 83 (03) : 185 - 190