Experimental investigation of the performance of an air type photovoltaic thermal collector system with fixed cooling fins

被引:7
|
作者
Zhao, Zhonghua [1 ,4 ]
Zhu, Li [1 ,2 ]
Wang, Yiping [1 ,3 ]
Huang, Qunwu [3 ]
Sun, Yong [1 ,2 ]
机构
[1] Tianjin Univ, Sch Architecture, Tianjin 300072, Peoples R China
[2] Tianjin Univ, APEC Sustainable Energy Ctr, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Sch Chem Engn & Technol, Tianjin 300072, Peoples R China
[4] Tianjin Renai Coll, Tianjin 301636, Peoples R China
关键词
Photovoltaic thermal (PV/T); Solar air collector; Thermal efficiency; Cooling fin; PV/T COLLECTOR; DESIGN;
D O I
10.1016/j.egyr.2023.02.059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar energy may now be captured in two ways: heat extraction in solar collectors and electricity generation in photovoltaic panels. It may effectively reduce the degradation of PV cell efficiency caused by overheating of the battery by collecting the heat from the PV/T system. The heat dissipation cooling fin is directly mounted to the rear of the solar panel in this study and coated with an insulating layer to create an air-cooling channel. The heat dissipation fin transfers heat from the back of the photovoltaic panel to a certain mass flow of air in the flow channel, resulting in combined heat and power. The electrical and thermal capabilities of three distinct fin numbers were studied by monitoring electrical power and temperature data. A fixed mass flow rate (0.011 kg/s) for air, three different numbers of fins (0-5-10) and solar irradiance (200 W/m(2)-600 W/m(2)) are the experimental conditions. After the system was run stably for 10 min, the average temperature of the back of the PV panel, the device's inlet and outlet temperatures, and the PV panel's electric power were recorded. These figures are used to calculate the PV/T system's electrical and thermal efficiency. When the median electrical efficiency of the three types of fins is compared with varying solar irradiation, it is discovered that the electric efficiency value of the three types of fins is approximately 16%, with a difference of less than 0.6%. The comprehensive efficiency of five groups of fins and ten groups of fins was 61.08% and 69.85%, respectively, based on the median comparison of photoelectric photothermal comprehensive efficiency. The overall efficiency of the zero groups of fins was 26.27%, which was only 14.59% greater than the control plate, and there was a considerable difference between the five and ten groups of fins. This suggests that selecting the right number of fins has a substantial impact on improving PV/T thermal performance. This research will assist in further optimizing the design of PV/T systems for heat collection and will provide valuable information for PV/T system application in building integration. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under theCCBYlicense (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [31] Experimental and computational fluid dynamics analysis of a photovoltaic/thermal system with active cooling using aluminum fins
    Omeroglu, Gokhan
    JOURNAL OF PHOTONICS FOR ENERGY, 2017, 7 (04):
  • [32] An experimental investigation of energy production with a hybrid photovoltaic/thermal collector system in Duhok city
    Ali, Omar Mohammed
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [33] Performance evaluation of new type hybrid photovoltaic/thermal solar collector by experimental study
    Liang, Ruobing
    Zhang, Jili
    Ma, Liangdong
    Li, Yuanyuan
    APPLIED THERMAL ENGINEERING, 2015, 75 : 487 - 492
  • [34] The Water Based Photovoltaic Thermal Fiberglass Collector: An Experimental Investigation
    Mustafa, Wan
    Fudholi, Ahmad
    Sopian, Kamaruzzaman
    Mustapha, Muslizainun
    Ahmudiarto, Yoyon
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2021, 11 (04): : 1663 - 1672
  • [35] Development and experimental investigation of photovoltaic-thermal collector design
    Nizetic, Sandro
    Jurcevic, Mik
    Coko, Duje
    Arici, Muslum
    Giama, Efrosini
    Papadopoulos, Agis
    6TH INTERNATIONAL CONFERENCE ON COUNTERMEASURES TO URBAN HEAT ISLANDS, UHI 2023, 2023, : 99 - 105
  • [36] An experimental study of a photovoltaic thermal air collector (PVTAC): A comparison of a flat and the wavy collector
    Jha, Prabhakar
    Das, Biplab
    Gupta, Rajat
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [37] Comparative Experimental Investigation on Front Cooling for Tempered Glass Photovoltaic Thermal System
    Selvaraj, Jeyraj
    Tharmarajah, Naveenrajah
    Umam, Mukhamad Faeshol
    Kumar, Laveet
    Hasanuzzaman, Md.
    Abd Rahim, Nasrudin
    Basuhaib, Abdullah Abdulmuhsen Saleh
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (03) : 7245 - 7261
  • [38] Experimental investigation of the thermal performance of the thermosyphon cooling system with rotating
    Yamaguchi, K.
    Takei, S.
    Izumi, M.
    33RD INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS2020), 2021, 1975
  • [39] Thermal performance enhancement of solar air heater using louvered fins collector
    Chand, Subhash
    Chand, Prabha
    Ghritlahre, Harish Kumar
    SOLAR ENERGY, 2022, 239 : 10 - 24
  • [40] Experimental investigation of using the evaporative air cooling technique to enhance the performance of the photovoltaic module
    Jaffar, Malik F.
    Mohammad, Abdulrahman Th
    Ahmed, Ahmed Qasim
    Al-Shohani, Wisam A. M.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1231 - 1245