An electrochemical sensor based on CS-MWCNT and AuNPs for the detection of mycophenolic acid in plasma

被引:2
|
作者
Xiong, Yan [1 ]
Zhu, Shu [2 ]
Zhao, Hua [1 ]
Li, Jin [1 ,3 ]
Li, Yanting [1 ]
Gong, Tao [4 ]
Tao, Yanru [1 ]
Hu, Jiangling [1 ]
Wang, Hongmei [1 ,5 ]
Jiang, Xinhui [1 ,6 ]
机构
[1] Chongqing Med Univ, Chongqing Res Ctr Pharmaceut Engn, Sch Pharm, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Lab Teaching & Management Ctr, Lab Pharm & Chem, Chongqing 400016, Peoples R China
[3] Chongqing Med Univ, Childrens Hosp Affiliated, Dept Pharm, Chongqing 400014, Peoples R China
[4] Nanchong Cent Hosp, Nanchong Key Lab Individualized Drug Therapy, Nanchong 637000, Sichuan, Peoples R China
[5] Chongqing Lybon Pharm Tech Co Ltd, Fu Pharmaceut Grp, Chongqing 401121, Peoples R China
[6] Chongqing Med Univ, Chongqing Res Ctr Pharmaceut Engn, Sch Pharm, 1 Yixueyuan Rd, Chongqing 400016, Peoples R China
关键词
Mycophenolic acid; Cyclic voltammetry; Green electrochemical sensor; CS-MWCNT; AuNPs; GCE; High performance liquid phase; REDUCED GRAPHENE OXIDE; GOLD NANOPARTICLES; CARBON NANOTUBES; SENSITIVE DETERMINATION; MECHANICAL-PROPERTIES; IONIC LIQUID; CHITOSAN; ELECTRODE; MOFETIL; IMMUNOSENSOR;
D O I
10.1016/j.ab.2023.115265
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For patients receiving organ transplants, monitoring the blood concentration of MPA can provide timely information on whether MPA has reached the effective therapeutic window to better function while reducing the incidence of rejection or adverse reactions. In this study, an electrochemical sensor for the detection of MPA was built using a nanocomposite made of CS-MWCNT and AuNPs. At the same time, the high performance liquid phase (HPLC) method for MPA was established and compared with this sensor. The surface morphology, structure, and roughness of the material on the electrode were characterized by scanning electron microscopy (SEM), Fourier transforms infrared spectroscopy (FTIR), and atomic force microscopy (AFM). In addition, the electrochemical behavior of the modified electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The standard curve was obtained in blank plasma, not pure buffer solution. The peak current was linearly related to the MPA concentration in the linear range of 0.001-0.1 mM with a detection limit of 0.05 & mu;M and good anti-interference ability. Moreover, the sensor was employed with success for the determination of MPA in rat plasma with good recovery. The electrochemical sensor presented here is eco-friendly, and sensitive, and offers a great possibility for practical applicability.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Aptasensor Based on Screen-Printed Carbon Electrodes Modified with CS/AuNPs for Sensitive Detection of Okadaic Acid in Shellfish
    Zeng, Ni
    Wang, Xinyi
    Dong, Yiyang
    Yang, Yan
    Yin, Yingai
    Zhao, Lianhui
    Wang, Xu
    JOURNAL OF ANALYSIS AND TESTING, 2023, 7 (02) : 128 - 135
  • [32] Aptasensor Based on Screen-Printed Carbon Electrodes Modified with CS/AuNPs for Sensitive Detection of Okadaic Acid in Shellfish
    Ni Zeng
    Xinyi Wang
    Yiyang Dong
    Yan Yang
    Yingai Yin
    Lianhui Zhao
    Xu Wang
    Journal of Analysis and Testing, 2023, 7 : 128 - 135
  • [33] CeO2-MWCNT nanocomposite based electrochemical sensor for acetaldehyde
    Shereema, Rayammarakkar M.
    Nambiar, Sindhu R.
    Shankar, S. Sharath
    Rao, Talasila P.
    ANALYTICAL METHODS, 2015, 7 (12) : 4912 - 4918
  • [34] Boronic acid based imprinted electrochemical sensor for rutin recognition and detection
    Wang, Chunlei
    Wang, Qi
    Zhong, Min
    Kan, Xianwen
    ANALYST, 2016, 141 (20) : 5792 - 5798
  • [35] Electrochemical Sensor Based on Covalent Organic Framework for Detection of Folic Acid
    Yul, Yan
    Yong-mei, Hu
    Fang, Xu
    Jin-shengl, Liao
    Hai-pingl', Huang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (07) : 1163 - 1170
  • [36] Electrochemical Sensor for Cd2+ Detection Based on Carbon Fiber Paper Sequentially Modified With CoMOF, AuNPs, and Glutathione
    Qi, Yanli
    Chen, Xiaolong
    Liu, Shasha
    Yang, Ping
    Zhang, Suyi
    Hou, Changjun
    Huo, Danqun
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (06)
  • [37] Molecular Imprinting Polymers Electrochemical Sensor Based on AuNPs/PTh Modified GCE for Highly Sensitive Detection of Carcinomaembryonic Antigen
    Lai, Yuxuan
    Deng, Yan
    Yang, Gaojian
    Li, Song
    Zhang, Chuanxiang
    Liu, Xueying
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2018, 14 (10) : 1688 - 1694
  • [38] Development of MWCNT decorated with green synthesized AgNps-based electrochemical sensor for highly sensitive detection of BPA
    Verma, Damini
    Chauhan, Deepika
    Das Mukherjee, Maumita
    Ranjan, Kumar Rakesh
    Yadav, Amit K.
    Solanki, Pratima R.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2021, 51 (03) : 447 - 462
  • [39] Development of MWCNT decorated with green synthesized AgNps-based electrochemical sensor for highly sensitive detection of BPA
    Damini Verma
    Deepika Chauhan
    Maumita Das Mukherjee
    Kumar Rakesh Ranjan
    Amit K. Yadav
    Pratima R. Solanki
    Journal of Applied Electrochemistry, 2021, 51 : 447 - 462
  • [40] g-C3N4/MWCNT nanocomposite based electrochemical sensor for hydrogen peroxide detection
    Shukla S.
    Prakash Ojha R.
    Ji G.
    Prakash R.
    Materials Today: Proceedings, 2023, 80 : 183 - 187