Diagnostic accuracy of the 4AT for delirium: A systematic review and meta-analysis

被引:7
|
作者
Hou, Liangying [1 ,2 ]
Zhang, Qian [3 ]
Cao, Liujiao [4 ]
Chen, Meixi [5 ]
Wang, Qi [1 ,6 ]
Li, Yanfei [1 ,2 ]
Li, Sheng [7 ]
Ge, Long [1 ,2 ,8 ]
Yang, Kehu [1 ,2 ,8 ]
机构
[1] Lanzhou Univ, Evidence Based Med Ctr, Sch Basic Med Sci, Lanzhou 730000, Peoples R China
[2] Lanzhou Univ, Evidence Based Social Sci Res Ctr, Sch Publ Hlth, Lanzhou 730000, Peoples R China
[3] Univ Ottawa, Fac Hlth Sci, Sch Nursing, Ottawa, ON, Canada
[4] Sichuan Univ, West China Hosp, West China Sch Nursing, Chengdu, Peoples R China
[5] Lanzhou Univ, Sch Clin Med 2, Lanzhou 730000, Peoples R China
[6] Lanzhou Univ, Dept Social Med & Hlth Management, Sch Publ Hlth, Lanzhou 730000, Peoples R China
[7] First Peoples Hosp Lanzhou City, Lanzhou 730000, Peoples R China
[8] Key Lab Evidence Based Med & Knowledge Translat Ga, Lanzhou 730000, Peoples R China
关键词
Delirium; Geriatrics; 4AT; Diagnostic; Meta; -analysis; METHODOLOGICAL QUALITY; COGNITIVE IMPAIRMENT; CARE; VALIDATION; INSTRUMENT; TESTS;
D O I
10.1016/j.ajp.2022.103374
中图分类号
R749 [精神病学];
学科分类号
100205 ;
摘要
Introduction: Despite common, serious, costly, and often fatal conditions affecting up to 50 % of older patients, delirium is often unrecognized and overlooked. We examine the accuracy of the 4AT for detecting older patients with delirium.Methods: We performed a systematic search of PubMed, Web of Science, PsycINFO, and EMBASE databases from inception to April 2020 and updated to January 2022. Four independently reviewers extracted study data and assessed the methodological quality using the revised quality assessment of diagnostic accuracy studies tool (QUADAS-2). Pooled estimates of sensitivity and specificity were generated using a bivariate random effects model. All statistical analyses were performed with STATA version 15.1 and Meta-DiSc version 1.4 software. Results: Eleven studies with 2789 participants were included. The pooled sensitivity and specificity were 0.87 (95 % CI: 0.81-0.91) and 0.87 (95 % CI: 0.79-0.92), respectively, and the positive and negative likelihood ratios were 6.66 (95 % CI: 4.12-10.74) and 0.15 (95 % CI: 0.10-0.23), respectively. Deeks' test indicated no significant publication bias (t = 0.83, P = 0.43). Univariable meta-regression showed that patient selection and flow and timing significantly influenced the pooled sensitivity (P < 0.05), settings significantly influenced the pooled specificity (P < 0.05).Conclusion: Our meta-analysis demonstrates that 4AT is a sensitive and specific screening tool for delirium in older patients. Its brevity and simplicity support its use in routine clinical practice, particularly in time-poor settings. Clinicians should come to a conclusion based largely on the 4AT findings in conjunction with clinical judgment.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Systematic review and meta-analysis: diagnostic accuracy of exosomes in pancreatic cancer
    Xu, Xinyi
    Long, Chunyue
    Li, Meng
    Shen, Chen
    Ye, Qiuwen
    Li, Yong
    Li, Hongyang
    Cao, Xia
    Ma, Jun
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2025, 23 (01)
  • [32] The Accuracy of Diagnostic Methods for Diabetic Retinopathy: A Systematic Review and Meta-Analysis
    Martinez-Vizcaino, Vicente
    Cavero-Redondo, Ivan
    Alvarez-Bueno, Celia
    Rodriguez-Artalejo, Fernando
    PLOS ONE, 2016, 11 (04):
  • [33] Accuracy of Emergency Department Delirium Screening: A Diagnostic Meta-Analysis
    Carpenter, C. R.
    Kennedy, M.
    Arendts, G.
    Schnitker, L.
    Eagles, D.
    Mooijaart, S.
    Fowler, S.
    LaMantia, M.
    Han, J.
    ANNALS OF EMERGENCY MEDICINE, 2018, 72 (04) : S96 - S97
  • [34] Diagnostic accuracy of periostin in predicting asthma: a systematic review and Meta-analysis
    Jia, Xinyu
    Li, Shan
    Xu, TingTing
    Ji, Ningfei
    Huang, Mao
    JOURNAL OF ASTHMA, 2021, 58 (03) : 307 - 315
  • [35] The clock drawing test: A systematic review and meta-analysis of diagnostic accuracy
    Park, JinKyung
    Jeong, EunHye
    Seomun, GyeongAe
    JOURNAL OF ADVANCED NURSING, 2018, 74 (12) : 2742 - 2754
  • [36] Diagnostic Accuracy of Urinary Biomarkers in Periodontitis: A Systematic Review and Meta-Analysis
    Fratini, Adriano
    Izzetti, Rossana
    Riccetti, Nicola
    Gennai, Stefano
    Graziani, Filippo
    Marchetti, Enrico
    INTERNATIONAL JOURNAL OF DENTISTRY, 2024, 2024
  • [37] Diagnostic Accuracy of ChatGPT for Patients' Triage; a Systematic Review and Meta-Analysis
    Kaboudi, Navid
    Firouzbakht, Saeedeh
    Eftekhar, Mohammad Shahir
    Fayazbakhsh, Fatemeh
    Joharivarnoosfaderani, Niloufar
    Ghaderi, Salar
    Dehdashti, Mohammadreza
    Kia, Yasmin Mohtasham
    Afshari, Maryam
    Vasaghi-Gharamaleki, Maryam
    Haghani, Leila
    Moradzadeh, Zahra
    Khalaj, Fattaneh
    Mohammadi, Zahra
    Hasanabadi, Zahra
    Shahidi, Ramin
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2024, 12 (01)
  • [38] Comment on 'Comparative Diagnostic Accuracy of Nursing Delirium Screening Scale Versus Confusion Assessment Method for Postoperative Delirium: A Systematic Review and Meta-Analysis'
    Mehta, Rachana
    Shabil, Muhammed
    Sah, Sanjit
    Soni, Priyal
    JOURNAL OF CLINICAL NURSING, 2024,
  • [39] Diagnostic accuracy of circular RNA for diabetes Mellitus: a systematic review and diagnostic Meta-analysis
    Dehghanbanadaki, Hojat
    Asili, Pooria
    Haji Ghadery, Abdolkarim
    Mirahmad, Maryam
    Dehnavi, Ali Zare
    Parsaei, Amirhossein
    Baradaran, Hamid Reza
    Azami, Mobin
    Jose Justo da Silva, Gustavo
    Parvan, Reza
    Moradi, Yousef
    BMC MEDICAL GENOMICS, 2023, 16 (01)
  • [40] Diagnostic accuracy of circular RNA for diabetes Mellitus: a systematic review and diagnostic Meta-analysis
    Hojat Dehghanbanadaki
    Pooria Asili
    Abdolkarim Haji Ghadery
    Maryam Mirahmad
    Ali Zare Dehnavi
    Amirhossein Parsaei
    Hamid Reza Baradaran
    Mobin Azami
    Gustavo Jose Justo da Silva
    Reza Parvan
    Yousef Moradi
    BMC Medical Genomics, 16