The Utility of Near-Infrared Autofluorescence for Parathyroid Gland Identification During Thyroid Surgery: A Single-Center Experience

被引:1
|
作者
Tjahjono, Richard [1 ,3 ]
Phung, Daniel [2 ]
Elliott, Michael S. [2 ,3 ]
Riffat, Faruque [1 ,2 ,3 ]
Palme, Carsten E. [2 ,3 ]
机构
[1] Westmead Hosp, Dept Otolaryngol Head & Neck Surg, Sydney, NSW, Australia
[2] Univ Sydney, Dept Head & Neck Surg, Chris OBrien Lifehouse, 119-143 Missenden Rd, Camperdown, NSW 2050, Australia
[3] Univ Sydney, Fac Med, Sydney, NSW, Australia
关键词
Parathyroid; Thyroid; Thyroidectomy; Autofluorescence; Identification; FLUORESCENCE; LOCALIZATION; ANATOMY;
D O I
10.1007/s12070-022-03309-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Parathyroid gland injury during thyroid surgery is common and can lead to postoperative hypocalcemia. This study aims to determine the utility of near-infrared autofluorescence (NIRAF) technology for parathyroid gland identification in thyroid surgery. A prospective case series of patients who underwent thyroid surgery between March and June 2021 were examined. Following intra-operative visualisation, parathyroid glands and surrounding tissues were exposed to near-infrared light with a wavelength of approximately 800 nm using the Storz (R) Near-Infrared Range/Indocyanine Green (NIR/ICG) endoscopic system. Parathyroid glands were expected to show autofluorescence following exposure. Twenty patients who underwent thyroid surgery were included. Eighteen patients (90%) were female, with a median age of 50.0 (IQR 41.0 - 62.5). Surgeries performed include hemithyroidectomy (9 patients; 45.0%), total thyroidectomy (8 patients; 40.0%), completion thyroidectomy (2 patients; 10.0%) and right inferior parathyroidectomy (1 patient; 5.0%). Attempts were made to identify 56 parathyroid glands in this case series. There were 46/56 (82.1%) surgeon-identified parathyroid glands through direct visualisation. Using NIRAF technology, 39/46 (84.8%) were identified as parathyroid glands. There was no inadvertent resection of parathyroid glands or post-operative hypocalcaemia. NIRAF technology has the potential to be a useful tool in confirming the presence of parathyroid glands following direct visualisation intra-operatively.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [21] Identification of inadvertently removed parathyroid glands during thyroid surgery using autofluorescence
    Serra, Carlos
    Silveira, Luis
    Canudo, Antonio
    GLAND SURGERY, 2020, 9 (04) : 893 - 898
  • [22] Structure-inherent targeting of near-infrared fluorophores for parathyroid and thyroid gland imaging
    Hyun, Hoon
    Park, Min Ho
    Owens, Eric A.
    Wada, Hideyuki
    Henary, Maged
    Handgraaf, Henricus J. M.
    Vahrmeijer, Alexander L.
    Frangioni, John V.
    Choi, Hak Soo
    NATURE MEDICINE, 2015, 21 (02) : 192 - 197
  • [23] Near-Infrared Autofluorescence Imaging in Thyroid Surgery: A Systematic Review and Meta-Analysis
    Lu, Wei
    Chen, Qiang
    Zhang, Pei
    Su, Anping
    Zhu, Jingqiang
    JOURNAL OF INVESTIGATIVE SURGERY, 2022, 35 (09) : 1723 - 1732
  • [24] Advancing parathyroid surgery: a critical examination of probe-based near-infrared autofluorescence technology
    Demarchi, Marco Stefano
    Triponez, Frederic
    GLAND SURGERY, 2024, 13 (06) : 1137 - 1140
  • [25] Structure-inherent targeting of near-infrared fluorophores for parathyroid and thyroid gland imaging
    Hoon Hyun
    Min Ho Park
    Eric A Owens
    Hideyuki Wada
    Maged Henary
    Henricus J M Handgraaf
    Alexander L Vahrmeijer
    John V Frangioni
    Hak Soo Choi
    Nature Medicine, 2015, 21 : 192 - 197
  • [26] Indocyanine green as a near-infrared fluorescent agent for identifying parathyroid glands during thyroid surgery in dogs
    Suh, Yong Joon
    Choi, June Young
    Chai, Young Jun
    Kwon, Hyungju
    Woo, Jung-Woo
    Kim, Su-jin
    Kim, Kyu Hyung
    Lee, Kyu Eun
    Lim, Yong Taik
    Youn, Yeo-Kyu
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (09): : 2811 - 2817
  • [27] Indocyanine green as a near-infrared fluorescent agent for identifying parathyroid glands during thyroid surgery in dogs
    Yong Joon Suh
    June Young Choi
    Young Jun Chai
    Hyungju Kwon
    Jung-Woo Woo
    Su-jin Kim
    Kyu Hyung Kim
    Kyu Eun Lee
    Yong Taik Lim
    Yeo-Kyu Youn
    Surgical Endoscopy, 2015, 29 : 2811 - 2817
  • [28] Near-infrared imaging in re-operative parathyroid surgery: first description of autofluorescence from cryopreserved parathyroid glands
    Moore, Edwina C.
    Rudin, Anthony
    Alameh, Anas
    Berber, Eren
    GLAND SURGERY, 2019, 8 (03) : 283 - 286
  • [29] Thyroid surgery in children: a single-center experience of 20 years
    Bahadir, Kutay
    Ural, Selin
    Abdullayev, Javid
    Karaman, Abdurrahman
    Parlak, Mesut
    Boz, Adil
    Karaguzel, Gungor
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2024, 70 (07):
  • [30] Influence of Single Experience with Intraoperative Near-Infrared Autofluorescence on Postoperative Parathyroid Insufficiency after Thyroidectomy-A Preliminary Clinical Study
    Domoslawski, Pawel
    Adamiecki, Marcin
    Antkowiak, Lukasz
    Pasko, Krzysztof
    Chabowski, Mariusz
    Grzegrzolka, Jedrzej
    Zrabkowski, Michal
    Bialecki, Jacek
    Antkowiak, Ryszard
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2022, 19 (08): : 1334 - 1339