共 50 条
A comparison of measles-rubella-zoster reaction, oligoclonal IgG bands, oligoclonal kappa free light chains and kappa index in multiple sclerosis
被引:3
|作者:
Revendova, Kamila Zondra
[1
,2
]
Svub, Krystof
[1
]
Bunganic, Radovan
[1
,2
]
Pelisek, Ondrej
[1
]
Volny, Ondrej
[1
,2
,3
]
Ganesh, Aravind
[4
,5
,6
]
Bar, Michal
[1
,2
]
Zeman, David
[7
]
Kusnierova, Pavlina
[8
,9
]
机构:
[1] Univ Hosp Ostrava, Dept Neurol, Ostrava, Czech Republic
[2] Univ Ostrava, Fac Med, Dept Clin Neurosci, Ostrava, Czech Republic
[3] Inst Hlth Informat & Stat Czech Republ, Prague, Czech Republic
[4] Univ Calgary, Hotchkiss Brain Inst, Dept Clin Neurosci, Cumming Sch Med, Calgary, AB, Canada
[5] Univ Calgary, Hotchkiss Brain Inst, Dept Community Hlth Sci, Cumming Sch Med, Calgary, AB, Canada
[6] Univ Calgary, OBrien Inst Publ Hlth, Cumming Sch Med, Calgary, AB, Canada
[7] Univ Hosp Brno, Inst Lab Med, Brno, Czech Republic
[8] Univ Hosp Ostrava, Inst Lab Med, Ostrava, Czech Republic
[9] Univ Ostrava, Inst Lab Med, Fac Med, Ostrava, Czech Republic
关键词:
MRZ reaction;
Multiple sclerosis;
Oligoclonal kappa free light chains;
Kappa index;
Oligoclonal IgG bands;
CEREBROSPINAL-FLUID ANALYSIS;
DIAGNOSIS;
VIRUS;
D O I:
10.1016/j.msard.2023.105125
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
Background and objectives: To evaluate the diagnostic performance of the measles-rubella-zoster reaction (MRZR) in a large real-world multiple sclerosis (MS) cohort. Second, to compare MRZR with the determination of oligoclonal IgG bands (OCB), oligoclonal kappa free light chain bands (oKFLC), and the KFLC index.Methods: A single-center retrospective study was conducted at the University Hospital Ostrava (Czech Republic). Patients were eligible if aged >= 18 years with a determined clinical diagnosis. IgG antibodies against measles (M), rubella (R), and varicella zoster (Z) viruses were determined in paired CSF and serum using ELISA and MRZR indicated as positive if at least two components had an antibody index >1.4. OCB and oKFLC were detected by means of isoelectric focusing, and KFLC CSF and serum concentrations for calculation of the KFLC index were determined immunochemically.Results: A total of 1,751 patients were included in the analyzed data set, which comprised 379 MS patients and 1,372 non-MS controls. The frequency of positive MRZR was higher in MS than in non-MS cases (MS 32.2 % vs non-MS 2.8 %; p < 0.001). This corresponded to a specificity of 97.2 % (95 % CI 96.1-98.0) and sensitivity of 32.2 % (95 % CI 27.5-37.2) and overall accuracy of 83.1 % (95 % CI 81.3-84.8). In comparison, the highest sensitivity of 95.6% (95 % CI 93.0-97.5) was for OCB with specificity of 86.9 % (95 % CI 84.9-88.7), followed by oKFLC with sensitivity and specificity of 94.7 % (95 % CI 91.5-96.9) and 78.4% (95 % CI 75.7-80.8), respectively, and the KFLC index with sensitivity of 92.5 % (95 % CI 86.6-96.3) and specificity of 93.5 % (95 % CI 90.5-95.9).Discussion: MRZR remains a very specific test for the diagnosis of MS but has low sensitivity, which disallows its independent use. In contrast, OCB showed the highest sensitivity and thus remains the gold standard for the diagnosis of MS.
引用
收藏
页数:7
相关论文