A Non-Invasive Method of Monitoring Glucose in Blood Using a Planar Yagi-Uda Antenna and Microstrip Filter

被引:3
|
作者
Nella, Anveshkumar [1 ]
Aldhaheri, Rabah Wasel [2 ]
Kamili, Jagadeesh Babu [3 ]
Sobahi, Nebras Mohammed Kamal A. [2 ]
机构
[1] VIT Bhopal Univ, Sch Elect & Elect Engn, Bhopal, India
[2] King Abdulaziz Univ, Dept Elect & Comp Engn, Jeddah, Saudi Arabia
[3] St Anns Coll Engn & Technol, Dept ECE, Chirala, India
关键词
Blood; Glucose levels (mg; dL); Microwave sensor; Microstrip filter; Non-invasive method; Yagi-Uda antenna; DIELECTRIC-PROPERTIES; SENSOR;
D O I
10.5755/j02.eie.31173
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents a non-invasive method to determine the glucose levels in blood samples using a planar Yagi-Uda antenna and a novel microstrip filter. The proposed antenna operates at 5.5 GHz and exhibiting uni-directional pattern giving a maximum gain of 6.74 dBi at the operating band. A commercially available and low-cost FR-4 substrate of dimensions 30 mmx40 mmx1.6 mm is used as a dielectric substrate. A finger phantom resembling a human finger is designed in the simulation environment, which consists of bone, skin, blood, fat as different layers. The glucose concentration is varied from 0 mg/dL to 500 mg/dL and the shifts in the frequencies are observed by keeping the phantom at various locations surrounding the antenna. A good frequency shift of 26 MHz is observed when the phantom is placed below the antenna. A good similarity is observed between the simulation and measurement results. Also, a novel microstrip filter, operating at 5.5 GHz, is developed, and the frequency shifts are studied by keeping a finger phantom at the top of the filter. The designed filter is shown to give a maximum frequency shift of 4 MHz when the glucose concentration changes from 250 mg/dL to 500 mg/dL. This study is supported by analysing transmission coefficient parameters and group delay characteristics.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [41] Preliminary SAR Analysis of Textile Antenna Sensor for Non-invasive Blood-Glucose Monitoring
    Costanzo, Sandra
    Cioffi, Vincenzo
    INFORMATION TECHNOLOGY AND SYSTEMS, ICITS 2020, 2020, 1137 : 607 - 612
  • [42] A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor
    Nella, Anveshkumar
    Aldhaheri, Rabah Wasel
    Kamili, Jagadeesh Babu
    Sobahi, Nebras Mohammed
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2023, 30 (01)
  • [43] A novel compact highly sensitive non-invasive microwave antenna sensor for blood glucose monitoring
    Aldhaheri, Rabah W.
    Kamili, Jagadeesh Babu
    Nella, Anveshkumar
    Sobahi, Nebras M.
    OPEN PHYSICS, 2023, 21 (01):
  • [44] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42
  • [45] Voltage Intensity Based Non-Invasive Blood Glucose Monitoring
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Kunnath, Abishek Thekkeyil
    2013 FOURTH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND NETWORKING TECHNOLOGIES (ICCCNT), 2013,
  • [46] Towards a Wearable Non-invasive Blood Glucose Monitoring Device
    Andrews, Joseph Thomas
    Solanki, J.
    Choudhary, Om P.
    Chouksey, S.
    Malvia, N.
    Chaturvedi, P.
    Sen, P.
    INTERNATIONAL CONFERENCE ON RECENT TRENDS IN PHYSICS (ICRTP 2012), 2012, 365
  • [47] New light upon non-invasive blood glucose monitoring
    Davies-Shaw, D.
    Davies, N.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS II, 2006, 6078
  • [48] Non-invasive monitoring of blood glucose in critically ill patients
    Weinstein, A.
    Herzenstein, O.
    Gabis, E.
    Singer, P.
    DIABETOLOGIA, 2008, 51 : S430 - S430
  • [49] Design and Analysis of Non-Invasive Blood Glucose Levels Monitoring
    Sari, Marti Widya
    Luthfi, Muhtar
    2016 1ST INTERNATIONAL SEMINAR ON APPLICATION FOR TECHNOLOGY OF INFORMATION AND COMMUNICATION (ISEMANTIC): SCIENCE AND TECHNOLOGY FOR A BETTER FUTURE, 2016, : 134 - 137
  • [50] A new generation of sensors for non-invasive blood glucose monitoring
    Wu, Juncen
    Liu, Yuqing
    Yin, Hao
    Guo, Meng
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (06): : 3825 - 3837