Improvements in image quality after optimization in digital intraoral radiographs

被引:2
|
作者
Barrineau, Ashley B. [1 ]
Mah, Peter [2 ]
Mallya, Sanjay M. [3 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Sect Endodont, Los Angeles, CA USA
[2] Dent Imaging Consultants, Box 29214 Med Ctr Stn, San Antonio, TX 78229 USA
[3] Univ Calif Los Angeles, Sch Dent, Sect Maxillofacial Radiol, Los Angeles, CA USA
来源
关键词
Quality control; quality assurance; image optimization; digital radiography; exposure optimization; radiographic phantom; image analysis; ASSURANCE; ACCURACY;
D O I
10.1016/j.adaj.2022.09.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Digital intraoral radiographic exposures are optimized largely on the basis of subjective assessment of diagnostic image quality. This study presents an objective approach to optimize radiographic exposure settings for digital intraoral radiographic systems.Methods. Seven size 2 digital intraoral systems were assessed for image quality and determination of optimal exposure following the protocol specified in American National Standard Institute/American Dental Association Standard No. 1094: Quality Assurance for Digital Intra-Oral Radiographic Systems. A ProX radiograph unit (Planmeca) at 63 kVp and 6 mA was used to obtain radiographs of the Dental Digital Quality Assurance phantom. ImageJ software (National Institutes of Health) was used to quantify dynamic range and spatial resolution, and contrast perceptibility was evaluated visually. Optimal exposure is the setting with the maximal contrast perceptibility and spatial resolution while displaying the full dynamic range. After image optimization, a custom phantom consisting of an endodontically prepared tooth was imaged to evaluate the file position relative to the apex for each system. Differences in distances between file position relative to the root apex at the optimal exposure as well as 1 increment above and below were measured.Results. Radiographic images obtained at the optimal exposure yielded better visualization and more accurate measurements of the file tip relative to the apex.Conclusions. Optimizing radiographic exposures improves image quality and accuracy in clinical decisions.Practical Implications. Improvement in image quality and better accuracy in actual distance of the endodontic file to the radiographic apex coupled with complete cleaning, shaping, and obturation of the canal should lead to better endodontic treatment outcomes.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [1] Diagnostic image quality of hard copies of digital intraoral and panoramic radiographs.
    Sanderink, GCH
    VanderStelt, PF
    Dula, K
    Huiskens, R
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1013 - 1013
  • [2] Does image file transfer, exposure time and optimization algorithm affect digital intraoral radiographs?
    Grzebieluch, Wojciech
    Kaczmarek, Urszula
    Staniowski, Tomasz
    Mikulewicz, Marcin
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 29 (12): : 1449 - 1458
  • [3] Comparative investigation of subjective image quality of digital intraoral radiographs processed with 3 image-processing algorithms
    Li, G
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2004, 97 (06): : 762 - 767
  • [4] Influence of JPEG image compression on indirect digital Intraoral radiographs.
    Christgau, M
    Hiller, KA
    Chou, SG
    Wenzel, A
    Schmalz, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A91 - A91
  • [5] IMAGE QUALITY AND DOSE REQUIREMENTS OF DIGITAL IMAGE INTENSIFIER RADIOGRAPHS
    BRAUNSCHWEIG, R
    BAUER, J
    SEEGER, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 159 (03): : 295 - 300
  • [6] Quality Assurance Audit of Digital Intraoral Periapical Radiographs at the Undergraduate Dental Clinics
    Javed, Muhammad Qasim
    Kolarkodi, Shaul Hameed
    Riaz, Arham
    Nawabi, Shazia
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (12): : 1339 - 1342
  • [7] Sliding window adaptive histogram equalization of intraoral radiographs: effect on image quality
    Sund, T
    Moystad, A
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (03) : 133 - 138
  • [8] The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
    Gullberg, Joanna
    Al-Okshi, Ayman
    Asan, Dalia Homar
    Zainea, Anita
    Sundh, Daniel
    Lorentzon, Mattias
    Lindh, Christina
    DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (01)
  • [9] The effects of compression on the image quality of digital panoramic radiographs
    Yasar, Fusun
    Yesilova, Esra
    Apaydin, Burcu
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 719 - 726
  • [10] The effects of compression on the image quality of digital panoramic radiographs
    Füsun Yasar
    Esra Yesilova
    Burcu Apaydın
    Clinical Oral Investigations, 2012, 16 : 719 - 726