Characterization of styrene/methyl methacrylate/n-butyl acrylate terpolymer with Kendrick mass defect analysis in electrospray ionization-ion mobility spectrometry-mass spectrometry

被引:3
|
作者
Ozeki, Yuka [1 ]
Kitagawa, Shinya [1 ]
Ohtani, Hajime [1 ]
Kondo, Yosuke [2 ]
Shidana, Hiroko [2 ]
机构
[1] Nagoya Inst Technol, Grad Sch Engn, Dept Life Sci & Appl Chem, Showa Ku, Gokiso Cho, Nagoya, Aichi 4668555, Japan
[2] Mitsubishi Chem Corp, Aoba Ku, 1000 Kamoshida Cho, Yokohama, Kanagawa 2278502, Japan
基金
日本学术振兴会;
关键词
STRUCTURAL-CHARACTERIZATION; SYNTHETIC-POLYMERS;
D O I
10.1002/rcm.9455
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleSynthesis of copolymer is one of the major approaches to establish sophisticated polymers. In copolymer analysis in mass spectrometry (MS), an increase in the number of monomer unit species and/or the polymer molecular weight results in complex mass spectra, and a method is required to solve this problem. MethodsIn this study, electrospray ionization-ion mobility spectrometry-mass spectrometry was employed to analyze styrene/methyl methacrylate/n-butyl acrylate (St/MMA/nBA) terpolymers via Kendrick mass defect (KMD) analysis. An expanded Fourier transform-based noise reduction method for the copolymer was developed to improve the decrease in the signal/noise ratio observed in the higher m/z region. ResultsLow-mass terpolymers (0.7 kDa) were identified by comparing the observed and theoretical results using a two-dimensional KMD plot. For the 1.5 kDa terpolymer, the signal overlap, of which KMD value was not matched with the theoretical one, was interpreted by the shift from the theoretical value in the KMD plot. For the 3.0 kDa terpolymers, the compositional candidates were determined by the prediction based on the compositional information of low-mass terpolymers previously analyzed. The 4.5 kDa terpolymer was interpreted after the expanded noise filtering. ConclusionsThe terpolymers, whose molecular weight was up to 4.5 kDa, were successfully characterized at a molecular level. The dependency of the St/MMA/nBA composition on molecular weight was observed; that is, the nBA content decreased with an increase in the molecular weight.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Electrospray Ionization Ion Mobility Mass Spectrometry of Human Brain Gangliosides
    Sarbu, Mirela
    Robu, Adrian C.
    Ghiulai, Roxana M.
    Vukelic, Zeljka
    Clemmer, David E.
    Zamfir, Alina D.
    ANALYTICAL CHEMISTRY, 2016, 88 (10) : 5166 - 5178
  • [32] Fundamentals of applying electrospray ionization mass spectrometry to low mass poly(methyl methacrylate) polymers
    McEwen, Charles N.
    Simonsick, William J. Jr.
    Larsen, Barbara S.
    Ute, Kaichi
    Hatada, Koichi
    Journal of the American Society for Mass Spectrometry, 1995, 6 (10):
  • [33] Analysis of antibiotics from liquid sample using electrospray ionization-ion mobility spectrometry
    Li, Shu
    Jia, Jian
    Gao, Xiaoguang
    He, Xiuli
    Li, Jianping
    ANALYTICA CHIMICA ACTA, 2012, 720 : 97 - 103
  • [34] Characterization of electrospray ionization mass spectrometry for N-diisopropyloxyphosphoryl dipeptide methyl esters
    Luo, SZ
    Li, YM
    Niu, YL
    Chen, Y
    Jiang, YY
    Chen, J
    Zhao, YF
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2005, 11 (01) : 107 - 117
  • [35] The potential for clinical applications using a new ionization method combined with ion mobility spectrometry-mass spectrometry
    Inutan, Ellen D.
    Wager-Miller, James
    Narayan, Srinivas B.
    Mackie, Ken
    Trimpin, Sarah
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2013, 16 (02) : 145 - 159
  • [36] Laserspray Ionization-Ion Mobility Spectrometry-Mass Spectrometry: Baseline Separation of Isomeric Amyloids without the Use of Solvents Desorbed and Ionized Directly from a Surface
    Inutan, Ellen D.
    Trimpin, Sarah
    JOURNAL OF PROTEOME RESEARCH, 2010, 9 (11) : 6077 - 6081
  • [37] Detection of Volatile Organic Compounds in Breath Using Thermal Desorption Electrospray Ionization-Ion Mobility-Mass Spectrometry
    Reynolds, J. C.
    Blackburn, G. J.
    Guallar-Hoyas, C.
    Moll, V. H.
    Bocos-Bintintan, V.
    Kaur-Atwal, G.
    Howdle, M. D.
    Harry, E. L.
    Brown, L. J.
    Creaser, C. S.
    Thomas, C. L. P.
    ANALYTICAL CHEMISTRY, 2010, 82 (05) : 2139 - 2144
  • [38] Tetraalkylammonium halides as chemical standards for positive electrospray ionization with ion mobility spectrometry/mass spectrometry
    Viidanoja, J
    Sysoev, A
    Adamov, A
    Kotiaho, T
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) : 3051 - 3055
  • [39] Characterization of primaquine imidazolidin-4-ones with antimalarial activity by electrospray ionization-ion trap mass spectrometry
    Vale, Nuno
    Moreira, Rui
    Gomes, Paula
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 270 (1-2) : 81 - 93
  • [40] Utilizing ion mobility spectrometry-mass spectrometry for the characterization and detection of persistent organic pollutants and their metabolites
    Noor A. Aly
    James N. Dodds
    Yu-Syuan Luo
    Fabian A. Grimm
    MaKayla Foster
    Ivan Rusyn
    Erin S. Baker
    Analytical and Bioanalytical Chemistry, 2022, 414 : 1245 - 1258