Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric in German

被引:0
|
作者
Cho, H. S. [1 ]
Seo, D. Y. [2 ,3 ]
Kim, D. S. [2 ,3 ]
Kang, J. S. [4 ]
Kim, Y. U. [5 ]
Kwon, Y. H. [6 ]
Kim, M. S. [3 ,6 ]
机构
[1] Cho Hyungsun Anim Hosp, Dept Vet Clin Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Vet Med, Dept Vet Clin Sci, PhD Student Vet Emergency & Crit Care, Seoul, South Korea
[3] Seoul Natl Univ, Res Inst Vet Sci, Seoul, South Korea
[4] Jeonbuk Natl Univ, Coll Vet Med, Dept Vet Clin Sci, Iksan, South Korea
[5] Bien Anim Med Ctr, Dept Vet Clin Sci, Sosagu, South Korea
[6] Seoul Natl Univ, Coll Vet Med, Dept Vet Clin Sci, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Biomechanical evaluation; Canine cadaver; Cementless; Load; Total hip arthroplasty; FEMORAL STRAIN; BONE INGROWTH; REPLACEMENT; MICROMOTION; ORIENTATION; DOGS; FIT;
D O I
10.22099/IJVR.2023.47029.6770
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: With the increasing use of cementless total hip arthroplasty (THA), stem subsidence has emerged as one of the primary complications. Although electron beam melting (EBM)-manufactured stems have been demonstrated to prevent subsidence, there has been limited investigation into the comparative biomechanical impact of collarless and collared EBM cementless stems on stem subsidence in veterinary medicine. Aims: This study aimed to compare the stem implant resistance and failure mechanical properties between collarless and collared EBM-manufactured stems. Methods: Seven pairs of femurs were harvested from canine cadavers. In each pair of femurs, the left femur was implanted with a collarless, and the right femur with a same-sized collared cementless stem. Specimen constructs were mounted to the loading frame of a testing machine and load was transferred to the femoral stem parallel to the longitudinal axis of the femur until the stem subsided 5 mm. Load and stem displacement data acquired during the tests were used to generate load-displacement curves and obtain stiffness, yield, and failure data for each specimen construct. Yield and failure energies were calculated as the areas under the load-displacement curves to the respective points. The effects of implant type and load during subsidence were analyzed using paired t-tests. Results: The yield and failure loads for the collared stems were approximately 40% greater than for the collarless stems (156.39 +/-; 43.63 kgf vs. 112.01 +/- 59.83 kgf, P<0.05). Conclusion: This study supported the advantages of collared EBM stems, including subsidence prevention and better initial stability for early osteointegration.
引用
收藏
页码:242 / 246
页数:6
相关论文
共 50 条
  • [21] Bicortical Contact Predicts Subsidence of Modular Tapered Stems in Revision Total Hip Arthroplasty
    Moriarty, Peter
    Sheridan, Gerard A.
    Wong, Liana
    Guerin, Shane
    Gul, Rehan
    Harty, James A.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (08): : 2195 - 2199
  • [22] EVALUATION OF BIOMECHANICAL MODELS FOR THE PLANNING OF TOTAL HIP ARTHROPLASTY
    Asseln, M.
    Eschweiler, J.
    Damm, P.
    Al Hares, G.
    Bergmann, G.
    Tingart, M.
    Radermacher, K.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [23] Radiographic and Biomechanical Assessment of Three Implant Designs for Canine Cementless Total Hip Replacement
    Worden, Natalie J.
    Ash, Kristian J.
    Ordway, Nathaniel R.
    Miller, Mark A.
    Mann, Kenneth A.
    VanDeventer, Gretchen M.
    Valenzano, Dominick M.
    Hart, Robert
    Kayano, Mitsunori
    Hayashi, Kei
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (06) : 417 - 427
  • [24] The Effect of Size for a Hydroxyapatite-Coated Cementless Implant on Component Revision in Total Hip Arthroplasty: An Analysis of 41,265 Stems
    Hoskins, Wayne T.
    Bingham, Roger J.
    Lorimer, Michelle
    de Steiger, Richard N.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (04): : 1074 - 1078
  • [25] Influence of cementless femoral stems inserted in varus on functional outcome in primary total hip arthroplasty
    de Beer, Justin
    McKenzie, Scott
    Hubmann, Matthias
    Petruccelli, Danielle
    Winemaker, Mitchell
    CANADIAN JOURNAL OF SURGERY, 2006, 49 (06) : 407 - 411
  • [26] Femoral stem subsidence in cementless total hip arthroplasty: a retrospective single-centre study
    Christian Ries
    Christoph Kolja Boese
    Florian Dietrich
    Wolfgang Miehlke
    Christian Heisel
    International Orthopaedics, 2019, 43 : 307 - 314
  • [27] Changes of bone mineral density after cementless total hip arthroplasty with two different stems
    Keiji Sano
    Kouji Ito
    Kengo Yamamoto
    International Orthopaedics, 2008, 32 : 167 - 172
  • [28] Excellent Survivorship With the Use of Proximally Coated Tapered Cementless Stems for Total Hip Arthroplasty in Octogenarians
    Stroh, D. Alex
    Zywiel, Michael G.
    Johnson, Aaron J.
    Mont, Michael A.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2011, 2 (03) : 100 - 104
  • [29] Femoral stem subsidence in cementless total hip arthroplasty: a retrospective single-centre study
    Ries, Christian
    Boese, Christoph Kolja
    Dietrich, Florian
    Miehlke, Wolfgang
    Heisel, Christian
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (02) : 307 - 314
  • [30] Changes of bone mineral density after cementless total hip arthroplasty with two different stems
    Sano, Keiji
    Ito, Kouji
    Yamamoto, Kengo
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (02) : 167 - 172