Design of a piezoelectrically actuated hydrocephalus shunt valve

被引:0
|
作者
Salih, O. [1 ]
Messina, M. [2 ]
Al-Jumeily, D. [3 ]
机构
[1] Liverpool John Moores Univ, Engn & Technol Res Inst, Liverpool, Merseyside, England
[2] Liverpool John Moores Univ, Mech Engn Dept, Liverpool, Merseyside, England
[3] Liverpool John Moores Univ, Sch Comp Sci & Math, Liverpool, Merseyside, England
关键词
Actuation; Hydrocephalus; Mechatronic valve; Piezoelectric; Shunt; Ultra-sonic motor; CEREBROSPINAL-FLUID; PRESSURE;
D O I
10.1007/s11517-023-02822-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Hydrocephalus is currently managed by using traditional mechanical passive shunts. Due to their nature, these shunts have fundamental shortcomings including an increase in patient shunt dependency, absence of fault detection, and over drainage due to lack of shunt proactivity. There is a scientific consensus that the way forward to address these issues is through what is termed a smart shunt. The core component of this system is the mechatronic controllable valve. A design of a valve which utilises both the passive nature of the classical valves and the controllability feature of the fully automated valves is presented in this paper. The valve consists of a fluid compartment, a linear spring, and an ultrasonic piezoelectric element. The valve is designed to operate on a 5 V supply, to drain up to 300 mL/h, and it has an operational range between 10 and 20 mmHg. The design produced is considered feasible as it takes into consideration the multiple operation conditions associated with such an implanted system.
引用
收藏
页码:2281 / 2290
页数:10
相关论文
共 50 条
  • [41] Piezoelectrically actuated miniature peristaltic pump
    Bar-Cohen, Y
    Chang, ZS
    SMART STRUCTURES AND MATERIALS 2001: SMART STRUCTURES AND INTEGRATED SYSTEMS, 2001, 4327 : 425 - 432
  • [42] A piezoelectrically actuated biomimetic walking robot
    Yumaryanto, Abdul A.
    An, Jaebum
    Lee, Sangpon
    EXPERIMENTAL MECHANICS IN NANO AND BIOTECHNOLOGY, PTS 1 AND 2, 2006, 326-328 : 1435 - +
  • [43] Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus
    Zemack, G
    Bellner, J
    Siesjö, P
    Strömblad, LG
    Romner, B
    JOURNAL OF NEUROSURGERY, 2003, 98 (03) : 471 - 476
  • [44] A piezoelectrically-actuated valve for modulation of liquid at high flow rate under high pressure
    Rajgopal, Srihari
    Knobloch, Aaron
    Kennerly, Stacey
    Mehregany, Mehran
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [45] A MODIFIED SLIT-VALVE SHUNT PROTOTYPE FOR THE MANAGEMENT OF HYDROCEPHALUS
    DIROCCO, C
    MANCINELLI, R
    POLA, P
    VELARDI, F
    JOURNAL OF NEUROSURGERY, 1981, 54 (06) : 763 - 766
  • [46] Use of the proGAV Shunt Valve in Normal-Pressure Hydrocephalus
    Toma, Ahmed K.
    Tarnaris, Andrew
    Kitchen, Neil D.
    Watkins, Laurence D.
    NEUROSURGERY, 2011, 68 : 245 - 249
  • [47] DESIGN OF A NEW PIEZOELECTRICALLY ACTUATED COMPLIANT MICROGRIPPER WITH HIGH AREA USAGE EFFICIENCY
    Lyu, Zekui
    Xu, Qingsong
    PROCEEDINGS OF ASME 2021 INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, IDETC-CIE2021, VOL 8A, 2021,
  • [48] Role of ventriculoperitoneal shunt valve design in the treatment of pediatric hydrocephalus-a single center study of valve performance in the clinical setting
    Beez, Thomas
    Sarikaya-Seiwert, Sevgi
    Bellstaedt, Lina
    Muehmer, Mario
    Steiger, Hans-Jakob
    CHILDS NERVOUS SYSTEM, 2014, 30 (02) : 293 - 297
  • [49] Analysis of design parameters for shunt valve and anti-siphon device used to treat patients with hydrocephalus
    Jang, JY
    Suh, CM
    Lee, CS
    KSME INTERNATIONAL JOURNAL, 2001, 15 (07): : 1061 - 1071
  • [50] Analysis of design parameters for shunt valve and anti-siphon device used to treat patients with hydrocephalus
    Jong Yun Jang
    Chang Min Suh
    Chong Sun Lee
    KSME International Journal, 2001, 15 : 1061 - 1071