Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen

被引:8
|
作者
Dal Bello, Riccardo [1 ,2 ,5 ]
Lapaeva, Mariia [1 ,2 ,3 ,4 ]
La Greca Saint-Esteven, Agustina [1 ,2 ,4 ]
Wallimann, Philipp [1 ,2 ]
Gunther, Manuel [3 ]
Konukoglu, Ender [4 ]
Andratschke, Nicolaus [1 ,2 ]
Guckenberger, Matthias [1 ,2 ]
Tanadini-Lang, Stephanie [1 ,2 ]
机构
[1] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Univ Zurich, Dept Informat, Artificial Intelligence & Machine Learning Grp, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Comp Vis Lab, Zurich, Switzerland
[5] Univ Spital Zurich USZ, Klin Radioonkol, Ramistr 100, CH-8091 Zurich, Switzerland
关键词
MR-guided radiotherapy; synthetic CT; Neural network; Quality assurance; PSQA; MR-Linac; CT; GENERATION; MRI;
D O I
10.1016/j.phro.2023.100464
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The superior tissue contrast of magnetic resonance (MR) compared to computed tomography (CT) led to an increasing interest towards MR-only radiotherapy. For the latter, the dose calculation should be performed on a synthetic CT (sCT). Patient-specific quality assurance (PSQA) methods have not been established yet and this study aimed to assess several software-based solutions.Materials and methods: A retrospective study was performed on 20 patients treated at an MR-Linac, which were selected to evenly cover four subcategories: (i) standard, (ii) air pockets, (iii) lung and (iv) implant cases. The neural network (NN) CycleGAN was adopted to generate a reference sCT, which was then compared to four PSQA methods: (A) water override of body, (B) five tissue classes with bulk densities, (C) sCT generated by a separate NN (pix2pix) and (D) deformed CT.Results: The evaluation of the dose endpoints demonstrated that while all methods A-D provided statistically equivalent results (p = 0.05) within the 2% level for the standard cases (i), only the methods C-D guaranteed the same result over the whole cohort. The bulk densities override was shown to be a valuable method in absence of lung tissue within the beam path.Conclusion: The observations of this study suggested that the use of an additional sCT generated by a separate NN was an appropriate tool to perform PSQA of a sCT in an MR-only workflow at an MR-Linac. The time and dose endpoints requirements were respected, namely within 10 min and 2%.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Deep Hybrid Learning Prediction of Patient-Specific Quality Assurance in Radiotherapy: Implementation in Clinical Routine
    Moreau, Noemie
    Bonnor, Laurine
    Jaudet, Cyril
    Lechippey, Laetitia
    Falzone, Nadia
    Batalla, Alain
    Bertaut, Cindy
    Corroyer-Dulmont, Aurelien
    DIAGNOSTICS, 2023, 13 (05)
  • [22] Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
    Wang, Yixuan
    Hu, Jiang
    Chen, Lixin
    Zhang, Dandan
    Zhu, Jinhan
    CANCER CONTROL, 2025, 32
  • [23] Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy
    Joshua Kim
    Kim Garbarino
    Lonni Schultz
    Kenneth Levin
    Benjamin Movsas
    M. Salim Siddiqui
    Indrin J. Chetty
    Carri Glide-Hurst
    Radiation Oncology, 10
  • [24] Usefulness of a new online patient-specific quality assurance system for respiratory-gated radiotherapy
    Kurosawa, Tomoyuki
    Tachibana, Hidenobu
    Moriya, Shunsuke
    Miyakawa, Shin
    Nishio, Teiji
    Sato, Masanori
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 63 - 72
  • [25] A comparison of three-film analysis software for stereotactic radiotherapy patient-specific quality assurance
    Buddhavarapu, Athreya
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (03):
  • [26] Evaluation of patient-specific motion management for radiotherapy planning computed tomography using a statistical method
    Tanabe, Yoshinori
    Eto, Hidetoshi
    MEDICAL DOSIMETRY, 2022, 47 (02) : E13 - E18
  • [27] Synthetic computed tomography data allows for accurate absorbed dose calculations in a magnetic resonance imaging only workflow for head and neck radiotherapy
    Palmer, Emilia
    Karlsson, Anna
    Nordstrom, Fredrik
    Petruson, Karin
    Siversson, Carl
    Ljungberg, Maria
    Sohlin, Maja
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 36 - 42
  • [28] Results of 2023 survey on the use of synthetic computed tomography for magnetic resonance Imaging-only radiotherapy: Current status and future steps
    Fusella, M.
    Andres, E. Alvarez
    Villegas, F.
    Milan, L.
    Janssen, T. M.
    Dal Bello, R.
    Garibaldi, C.
    Placidi, L.
    Cusumano, D.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [29] Synthetic computed tomography based dose calculation in prostate cancer patients with hip prostheses for magnetic resonance imaging-only radiotherapy
    Koivula, Lauri
    Seppala, Tiina
    Collan, Juhani
    Visapaa, Harri
    Tenhunen, Mikko
    Korhonen, Arthur
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [30] Synthetic CT Generation Using Structure-Aware Generative Adversarial Networks (SA-GANs) for Pelvis Magnetic Resonance-Only Radiotherapy
    Emami, H.
    Dong, M.
    Nejad-Davarani, S.
    Glide-Hurst, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E279 - E279