Differences in Automated External Defibrillator Types in Out-of-Hospital Cardiac Arrest Treated by Police First Responders

被引:2
|
作者
Krammel, Mario [1 ,2 ]
Eichelter, Jakob [1 ,3 ]
Gatterer, Constantin [1 ,4 ]
Lobmeyr, Elisabeth [5 ]
Neymayer, Marco [1 ,6 ]
Grassmann, Daniel [2 ]
Holzer, Michael [6 ]
Sulzgruber, Patrick [1 ,4 ]
Schnaubelt, Sebastian [1 ,6 ]
机构
[1] PULS Austrian Cardiac Arrest Awareness Assoc, A-1090 Vienna, Austria
[2] Emergency Med Serv MA70, A-1030 Vienna, Austria
[3] Med Univ Vienna, Dept Surg, A-1090 Vienna, Austria
[4] Med Univ Vienna, Dept Internal Med 2, Div Cardiol, A-1090 Vienna, Austria
[5] Med Univ Vienna, Dept Internal Med 1, A-1090 Vienna, Austria
[6] Med Univ Vienna, Dept Emergency Med, A-1090 Vienna, Austria
关键词
automated external defibrillator; out-of-hospital cardiac arrest; basic life support; police; first responder; EUROPEAN RESUSCITATION; SURVIVAL; EDUCATION; OUTCOMES; SYSTEMS; IMPACT; PAUSE;
D O I
10.3390/jcdd10050196
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Police first responder systems also including automated external defibrillation (AED) has in the past shown considerable impact on favourable outcomes after out-of-hospital cardiac arrest (OHCA). While short hands-off times in chest compressions are known to be beneficial, various AED models use different algorithms, inducing longer or shorter durations of crucial timeframes along basic life support (BLS). Yet, data on details of these differences, and also of their potential impact on clinical outcomes are scarce. Methods: For this retrospective observational study, patients with OHCA of presumed cardiac origin and initially shockable rhythm treated by police first responders in Vienna, Austria, between 01/2013 and 12/2021 were included. Data from the Viennese Cardiac Arrest Registry and AED files were extracted, and exact timeframes were analyzed. Results: There were no significant differences in the 350 eligible cases in demographics, return of spontaneous circulation, 30-day survival, or favourable neurological outcome between the used AED types. However, the Philips HS1 and -FrX AEDs showed immediate rhythm analysis after electrode placement (0 [0-1] s) and almost no shock loading time (0 [0-1] s), as opposed to the LP CR Plus (3 [0-4] and 6 [6-6] s, respectively) and LP 1000 (3 [2-10] and 6 [5-7] s, respectively). On the other hand, the HS1 and -FrX had longer analysis times of 12 [12-16] and 12 [11-18] s than the LP CR Plus (5 [5-6] s) and LP 1000 (6 [5-8] s). The duration from when the AED was turned on until the first defibrillation were 45 [28-61] s (Philips FrX), 59 [28-81] s (LP 1000), 59 [50-97] s (HS1), and 69 [55-85] s (LP CR Plus). Conclusion: In a retrospective analysis of OHCA-cases treated by police first responders, we could not find significant differences in clinical patient outcomes concerning the respective used AED model. However, various differences in time durations (e.g., electrode placement to rhythm analysis, analysis duration, or AED turned on until first defibrillation) along the BLS algorithm were seen. This opens up the question of AED-adaptations and tailored training methods for professional first responders.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Changes in automated external defibrillator use and survival after out-of-hospital cardiac arrest in the Nijmegen area
    J. Nas
    J. Thannhauser
    J. J. Herrmann
    K. van der Wulp
    P. M. van Grunsven
    N. van Royen
    M. J. de Boer
    J. L. Bonnes
    M. A. Brouwer
    Netherlands Heart Journal, 2018, 26 : 600 - 605
  • [32] Changes in automated external defibrillator use and survival after out-of-hospital cardiac arrest in the Nijmegen area
    Nas, J.
    Thannhauser, J.
    Herrmann, J. J.
    van der Wulp, K.
    van Grunsven, P. M.
    van Royen, N.
    de Boer, M. J.
    Bonnes, J. L.
    Brouwer, M. A.
    NETHERLANDS HEART JOURNAL, 2018, 26 (12) : 600 - 605
  • [33] Automated external defibrillator use and outcomes after out-of-hospital cardiac arrest: an Israeli cohort study
    Merdler, Ilan
    Sadeh, Ben
    Hochstadt, Aviram
    Kofman, Natalia
    Szekely, Yishay
    Steinvil, Arie
    Shacham, Yacov
    CORONARY ARTERY DISEASE, 2020, 31 (03) : 289 - 292
  • [34] Training of police officers as first responders with an automated external defibrillator
    Kooij, FO
    van Alem, AP
    Koster, RW
    de Vos, R
    RESUSCITATION, 2004, 63 (01) : 33 - 41
  • [35] USE OF THE AUTOMATIC EXTERNAL DEFIBRILLATOR IN THE MANAGEMENT OF OUT-OF-HOSPITAL CARDIAC-ARREST
    WEAVER, WD
    HILL, D
    FAHRENBRUCH, CE
    COPASS, MK
    MARTIN, JS
    COBB, LA
    HALLSTROM, AP
    NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (11): : 661 - 666
  • [36] Police as first reponders improve out-of-hospital cardiac arrest survival
    Louis, Clint Jean
    Cildoz, Marta
    Echarri, Alfredo
    Beaumont, Carlos
    Mallor, Fermin
    Greif, Robert
    Baigorri, Miguel
    Reyero, Diego
    BMC EMERGENCY MEDICINE, 2023, 23 (01)
  • [37] Police as first reponders improve out-of-hospital cardiac arrest survival
    Clint Jean Louis
    Marta Cildoz
    Alfredo Echarri
    Carlos Beaumont
    Fermin Mallor
    Robert Greif
    Miguel Baigorri
    Diego Reyero
    BMC Emergency Medicine, 23
  • [38] Occurrence of Fibrillation in Out-of-hospital Cardiac Arrest Patients Presenting in a Non-shockable Rhythm when Treated with an Automated External Defibrillator
    Liu, Chenguang
    Gao, Mengqi
    Gehman, Stacy
    Jorgenson, Dawn
    CIRCULATION, 2024, 150
  • [39] Rapid Responder Operating Times for Out-of-hospital Cardiac Arrest Using Three Automated External Defibrillator Models
    Gao, Mengqi
    Liu, Chenguang
    Jorgenson, Dawn
    CIRCULATION, 2020, 142
  • [40] Impact of epinephrine on neurological outcomes in out-of-hospital cardiac arrest after automated external defibrillator use in Japan
    Kubo, Atsushi
    Hiraide, Atsushi
    Shinozaki, Tomohiro
    Shibata, Naoaki
    Miyamoto, Kyohei
    Tamura, Shinobu
    Inoue, Shigeaki
    SCIENTIFIC REPORTS, 2025, 15 (01):