LHCb VELO fast calibration

被引:0
|
作者
Prieto, A. Fernndez [1 ]
机构
[1] Univ Santiago Compostela USC, Galician Inst High Energy Phys IGFAE, Bloque 4, Santiago De Compostela 15705, A Coruna, Spain
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 02期
关键词
Detector alignment and calibration methods (lasers; sources; particle-beams); Digital electronic circuits; Electronic detector readout concepts (solid-state); Control and monitor systems online;
D O I
10.1088/1748-0221/18/02/C02006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During the long shutdown 2 of the LHC, the LHCb Experiment was upgraded to a trigger-less system reading out the full detector at 40 MHz bunch crossing rate with all selection algorithms executed in a CPU farm. The upgraded Vertex Locator (VELO) of the LHCb is a hybrid pixel detector read out by the "VeloPix" front-end ASIC with on-chip zero-suppression. This paper describes a novel way of calibrating the VELO detector based on dedicated threshold scan firmware. The firmware is implemented in the control and data acquisition back-end boards of the detector. This threshold scan method has multiple advantages compared with the default one: it is faster as the algorithm was moved from software to firmware, it is more deterministic by minimizing software interruptions and data transfer and it is more precise by reducing noise due to ASIC operation.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The LHCb VELO analogue transmission line
    Bay, A.
    Borel, J.
    Buytaert, J.
    De Laere, S.
    Frei, R.
    Haefeli, G.
    Koppenburg, P.
    Locatelli, L.
    Schneider, O.
    Zehr, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 614 (01): : 34 - 40
  • [22] Developments towards the LHCb VELO upgrade
    Vidal, Xabier Cid
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 76 - 79
  • [23] Radiation damage on the LHCb-VELO
    Casse, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 730 : 18 - 23
  • [24] The LHCb VELO: Performance and radiation damage
    Snoek, H. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 765 : 35 - 40
  • [25] The LHCb VELO: Status and upgrade developments
    Bates, AG
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1174 - 1178
  • [26] LHCb VErtex LOcator (VELO) upgrade
    Reid, M. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 699 : 188 - 192
  • [27] The VELO (VErtex LOcator) at the LHCb experiment
    de Capua, S.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 946 - 950
  • [28] First Results from the LHCb VELO
    Rinnert, Kurt
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 931 - 934
  • [29] LHCb silicon: VELO and inner tracker
    Parzefall, U
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 120 : 230 - 234
  • [30] The LHCb VELO and its use in the trigger
    Ruf, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01): : 207 - 213