Attack Tolerant Fault Detection for CPSs: An Unknown Input Interval Observer Approach

被引:0
|
作者
Liu, Qidong [1 ]
Long, Yue [1 ,2 ]
Li, Tieshan [1 ,2 ]
Chen, C. L. Philip [1 ,3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu 611731, Peoples R China
[2] Lab Electromagnet Space Cognit & Intelligent Contr, Beijing 100089, Peoples R China
[3] South China Univ Technol, Sch Comp Sci & Engn, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Unknown input interval observer; actuator attacks; resilient fault detection; fuzzy CPSs; CYBER-PHYSICAL SYSTEMS; RESILIENT CONTROL; DESIGN;
D O I
10.1109/TASE.2024.3360967
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The interval observer, recognized as a potent tool for fault detection (FD), diverges from the adoption of fixed thresholds to enhance the timeliness and precision of detection. This study endeavors to design an FD mechanism for fuzzy cyber-physical systems (CPSs) subjected to adversarial influences based on improved attack tolerant interval observer. Specifically, the proposed frequency-information-based unknown input interval observer (UIIO) not only enables a more precise estimation of the interval range under the influence of attack signals but also isolates unknown decoupled inputs. Furthermore, it facilitates specific performance design for signals within a particular frequency range. Following the stability analysis of the system, linear solvable conditions are presented to ensure the robustness, fault sensitivity of the augmented system, as well as non-negativity of the augment system matrix. Finally, the proposed attack-tolerant FD mechanism is validated through simulation examples, including the influence of the prior attack information to detection interval width and the detection performance for small-amplitude faults or faults with specific frequency characteristics. Note to Practitioners-CPSs constitute the core of the next-generation manufacturing industry, applicable in areas like unmanned autonomous systems, smart grids, and intelligent healthcare, capitalizing on wide-ranging cyber space utilization. Nonetheless, this breadth also exposes them to elevated risks, including the threat of actuator attacks. The novel fault detection scheme developed in this paper is capable of operating in real-time when the system is confronted with various threats such as disturbances, faults, and actuator attacks. This approach obviates the requirement for knowledge about the nature of actuator attack signals, while enabling the generation of a system state estimation interval with a tunable error range. Leveraging frequency-dependent techniques, the developed scheme, even in the presence of potential actuator attack and disturbance, is particularly well-suited for the detection of fault signals with specific frequency domain characteristics.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Asymptotic convergence unknown input observer design via interval observer
    Zhu, Fanglai
    Fu, Yuhang
    Dinh, Thach Ngoc
    AUTOMATICA, 2023, 147
  • [42] Robust fault estimation for switched systems based on unknown input observer approach
    Du, Dongsheng
    Xu, Shengyuan
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 7416 - 7420
  • [43] A note on interval observer design for unknown input estimation
    Gucik-Derigny, D.
    Raissi, T.
    Zolghadri, A.
    INTERNATIONAL JOURNAL OF CONTROL, 2016, 89 (01) : 25 - 37
  • [44] A robust fault detection approach based on unknown input observers
    He, HF
    Hu, CH
    Dai, YM
    Shong, GM
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 8, 2005, : 303 - 306
  • [45] Fault diagnosis for a UAV using unknown input observer
    Kiyak, Emre
    Ermeydan, Ahmet
    INTERNATIONAL JOURNAL OF SUSTAINABLE AVIATION, 2016, 2 (04) : 309 - 326
  • [46] Robust unknown input observer for nonlinear systems and its application to fault detection and isolation
    Mondal, S.
    Chakraborty, G.
    Bhattacharyya, K.
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2008, 130 (04): : 0445031 - 0445035
  • [47] Robust H∞ Fault Detection for Fuzzy Bilinear Systems via Unknown Input Observer
    Saoudi, Dhikra
    Chadli, Mohammed
    Benhadj Braeik, Naceur
    2014 22ND MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2014, : 281 - 286
  • [48] Fault Detection and Isolation for a bus suspension model using an Unknown Input Observer Design
    Anzurez Marin, Juan
    Torres Salomao, Luis A.
    Lazaro, Isidro I.
    IMETI 2010: 3RD INTERNATIONAL MULTI-CONFERENCE ON ENGINEERING AND TECHNOLOGICAL INNOVATION, VOL I, 2010, : 170 - 175
  • [49] Robust fault detection via unknown input observer based on cubature Kalman filter
    Zarei, Jafar
    Shokri, Ehsan
    2013 21ST IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2013,
  • [50] Fault detection for networked control systems with time delays based on unknown input observer
    Yao, Jing
    Jiang, Bin
    Mao, Zehui
    Wang, Jianliang
    2007 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1-7, 2007, : 3030 - +