Architecture-Driven Digital Volume Correlation: Application to the Analysis of In-Situ Crushing of a Polyurethane Foam

被引:7
|
作者
Rouwane, A. [1 ]
Doumalin, P. [2 ]
Bouclier, R. [1 ,3 ]
Passieux, J. C. [1 ]
Perie, J. N. [1 ]
机构
[1] Univ Toulouse, Inst Clement Ader ICA, CNRS, INSA ISAE Mines Albi UPS, Toulouse, France
[2] Univ Poitiers, Inst PPRIME, CNRS, UPR 3346, Chasseneui, France
[3] Univ Toulouse, Inst Math Toulouse IMT, CNRS, UPS UT1 UT2 INSA, Toulouse, France
关键词
Digital volume correlation (DVC); Multigrid image registration; X-ray microtomography; Image-based mechanical modeling; Mechanical regularization; Cellular materials; Polyurethane foam; IMAGE CORRELATION TECHNIQUE; X-RAY TOMOGRAPHY; CANCELLOUS BONE; DEFORMATION; STRAIN; IDENTIFICATION; REGISTRATION; DISPLACEMENT; FORMULATION; PARAMETERS;
D O I
10.1007/s11340-023-00957-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background Digital Volume correlation (DVC) consists in identifying the displacement fields that allow for the best possible registration of volume images of a sample captured at various loading stages. With cellular materials, the use of DVC faces an intrinsic limit: in the absence of an exploitable texture on (or in) the struts or cell walls, the available speckle pattern will unavoidably be formed by the material architecture itself. This leads to the inability of classical DVC techniques to measure kinematics below the cellular scale, i.e. at the sub-cellular or micro scales. Objectives Here, we extend a newly developed architecture-driven DIC technique [1] for the measurement of 3D displacement fields in real cellular materials at the scale of the architecture. Methods The proposed solution consists in assisting DVC by a weak elastic regularization using, as support, an automatic finite-element image-based mechanical model. Results Complex (locally buckling) kinematics of a polyurethane foam under compression are accurately measured during an in-situ test. The method is essential to evidence the class of dominance (stretching versus bending) of the foam. Conclusion The proposed method allows to confirm that the foam used is bending-dominated, which is not possible with a classical mesoscopic DVC approach. This method is a good candidate for the analysis of complex local deformation mechanisms at the architecture scale.
引用
收藏
页码:897 / 913
页数:17
相关论文
共 50 条
  • [11] In-situ reliability analysis of solder joint by digital image correlation
    Pang, JHL
    Zhang, XR
    Liu, QJ
    Che, FX
    Low, TH
    Shi, XQ
    Wang, ZP
    PROCEEDINGS OF THE 4TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE (EPTC 2002), 2002, : 115 - 119
  • [12] Debonding analysis via digital volume correlation during in-situ pull-out tests on fractal fibers
    Jaenicke, G.
    Vintache, A.
    Smaniotto, B.
    Fau, A.
    Farina, I
    Fraternali, F.
    Hild, F.
    COMPOSITES PART C: OPEN ACCESS, 2022, 9
  • [13] In-situ Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation
    R. Brault
    A. Germaneau
    J. C. Dupré
    P. Doumalin
    S. Mistou
    M. Fazzini
    Experimental Mechanics, 2013, 53 : 1143 - 1151
  • [14] Application of Synchrotron Radiation–Computed Tomography In-Situ Observations and Digital Volume Correlation to Study Low-Cycle Fatigue Damage Micromechanisms in Lost Foam Casting A319 Alloy
    Long Wang
    Nathalie Limodin
    Ahmed El Bartali
    Jean-François Witz
    Jean-Yves Buffiere
    Eric Charkaluk
    Metallurgical and Materials Transactions A, 2020, 51 : 3843 - 3857
  • [15] In-situ analysis of laminated composite materials by X-ray micro-computed tomography and digital volume correlation
    Brault, R. (romain.brault@enit.fr), 1600, Society for Experimental Mechanics Inc. (53):
  • [16] In-situ Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation
    Brault, R.
    Germaneau, A.
    Dupre, J. C.
    Doumalin, P.
    Mistou, S.
    Fazzini, M.
    EXPERIMENTAL MECHANICS, 2013, 53 (07) : 1143 - 1151
  • [17] Internal Deformation Measurement of Polymer Bonded Sugar in Compression by Digital Volume Correlation of In-situ Tomography
    Z. Hu
    H. Luo
    S. G. Bardenhagen
    C. R. Siviour
    R. W. Armstrong
    H. Lu
    Experimental Mechanics, 2015, 55 : 289 - 300
  • [18] Internal Deformation Measurement of Polymer Bonded Sugar in Compression by Digital Volume Correlation of In-situ Tomography
    Hu, Z.
    Luo, H.
    Bardenhagen, S. G.
    Siviour, C. R.
    Armstrong, R. W.
    Lu, H.
    EXPERIMENTAL MECHANICS, 2015, 55 (01) : 289 - 300
  • [19] Application of digital image correlation for in-situ deformation studies using transmission electron microscopy
    Robinson, Accalia
    Homer, Eric R.
    Thompson, Gregory B.
    SCRIPTA MATERIALIA, 2024, 252
  • [20] In-situ digital image correlation for fracture analysis of oxides formed on zirconium alloys
    Platt, P.
    Lunt, D.
    Polatidis, E.
    Wenman, M. R.
    Preuss, M.
    CORROSION SCIENCE, 2016, 111 : 344 - 351