Videolaryngoscopy vs. flexible fibrescopy for tracheal intubation in patients with cervical spine immobilisation: a randomised controlled trial

被引:7
|
作者
Choi, S. [1 ]
Yoo, H. K. [1 ]
Shin, K. W. [1 ]
Kim, Y. J. [1 ]
Yoon, H. K. [1 ]
Park, H. P. [1 ]
Oh, H. [1 ]
机构
[1] Seoul Natl Univ Hosp, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
关键词
cervical collar; cervical spine immobilisation; flexible fibrescope; tracheal intubation; videolaryngoscope; ENDOTRACHEAL INTUBATION; FIBEROPTIC INTUBATION; ROCURONIUM BROMIDE; CORD-INJURY; SUCCINYLCHOLINE; AIRTRAQ(R); ORG-9426; AIRWAY;
D O I
10.1111/anae.16035
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In patients with cervical spine immobilisation, tracheal intubation devices other than a direct laryngoscope are frequently used to facilitate tracheal intubation and avoid related complications. In this randomised controlled trial, we compared videolaryngoscopic and fibrescopic tracheal intubation in patients with a cervical collar. Tracheal intubation was performed using either a videolaryngoscope with a non-channelled Macintosh blade (n = 166) or a flexible fibrescope (n = 164) in patients having elective cervical spine surgery whose neck was immobilised with a cervical collar to simulate a difficult airway. The primary outcome was the first attempt success rate of tracheal intubation. Secondary outcomes were the overall success rate of tracheal intubation; time to tracheal intubation; use of additional airway manoeuvres; and incidence and severity of tracheal intubation-related airway complications. First attempt success rate was higher in the videolaryngoscope group than in the fibrescope group (164/166 (98.8%) vs. 149/164 (90.9%), p = 0.003). Tracheal intubation was successful within three attempts in all patients. Median (IQR [range]) time to tracheal intubation was shorter (50.0 (41.0-72.0 [25.0-170.0]) s vs. 81.0 (65.0-107.0 [24.0-178.0]) s, p < 0.001) and additional airway manoeuvres were less frequent (30/166 (18.1%) vs. 91/164 (55.5%), p < 0.001) in the videolaryngoscope group compared with the fibrescope group. The incidence and severity of intubation-related airway complications were not different between the two groups. When performing tracheal intubation in patients with a cervical collar, videolaryngoscopy with a non-channelled Macintosh blade was superior to flexible fibrescopy.
引用
收藏
页码:970 / 978
页数:9
相关论文
共 50 条
  • [31] Safety of Airtraq® vs. fiberoptic intubation in patients with an unstable cervical spine fracture: a neurophysiological study
    Schoettker, P.
    Pralong, E.
    Duff, J. M.
    Fournier, N.
    Bathory, I.
    SWISS MEDICAL WEEKLY, 2015, 145 : 6S - 6S
  • [32] Cervical spine motion during tracheal intubation with manual in-line stabilization:: Direct laryngoscopy versus GlideScope® videolaryngoscopy
    Robitaille, Arnaud
    Williams, Stephan R.
    Tremblay, Marie-Helene
    Guilbert, Francois
    Theriault, Melanie
    Drolet, Pierre
    ANESTHESIA AND ANALGESIA, 2008, 106 (03): : 935 - 941
  • [34] First-attempt awake tracheal intubation success rate using a hyperangulated unchannelled videolaryngoscope vs. a channelled videolaryngoscope in patients with anticipated difficult airway: a randomised controlled trial
    Taboada, Manuel
    Fernandez, Jorge
    Estany-Gestal, Ana
    Vidal, Inma
    Dos Santos, Laura
    Novoa, Carmen
    Perez, Alejandra
    Segurola, Javier
    Franco, Edgar
    Regueira, Julia
    Miron, Paula
    Sotojove, Rosa
    Cortinas, Julio
    Carinena, Agustin
    Peiteado, Marcos
    Rodriguez, Alfonso
    Seoane-Pillado, Teresa
    ANAESTHESIA, 2024, 79 (11) : 1157 - 1164
  • [35] Cervical spine immobilization does not interfere with nasotracheal intubation performed using GlideScope videolaryngoscopy: a randomized equivalence trial
    Yi-Min Kuo
    Hsien-Yung Lai
    Elise Chia-Hui Tan
    Yi-Shiuan Li
    Ting-Yun Chiang
    Shiang-Suo Huang
    Wen-Cheng Huang
    Ya-Chun Chu
    Scientific Reports, 12 (1)
  • [36] Cervical spine immobilization does not interfere with nasotracheal intubation performed using GlideScope videolaryngoscopy: a randomized equivalence trial
    Kuo, Yi-Min
    Lai, Hsien-Yung
    Tan, Elise Chia-Hui
    Li, Yi-Shiuan
    Chiang, Ting-Yun
    Huang, Shiang-Suo
    Huang, Wen-Cheng
    Chu, Ya-Chun
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [37] Videolaryngoscopy vs. direct Macintosh laryngoscopy in tracheal intubation in adults: a ranking systematic review and network meta-analysis
    de Carvalho, C. C.
    Silva, D. M.
    Lemos, V. M.
    dos Santos, T. G. B.
    Agra, I. C.
    Pinto, G. M.
    Ramos, I. B.
    Costa, Y. S. C.
    Neto, J. M. Santos
    ANAESTHESIA, 2022, 77 (03) : 326 - 338
  • [38] Comparison of tracheal intubation using the Airtraq((R)) and Mc Coy laryngoscope in the presence of rigid cervical collar simulating cervical immobilisation for traumatic cervical spine injury
    Durga, Padmaja
    Kaur, Jasleen
    Ahmed, Syed Younus
    Kaniti, Geeta
    Ramachandran, Gopinath
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (06) : 529 - 534
  • [39] Cuffed vs. uncuffed tracheal tubes in children: a randomised controlled trial comparing leak, tidal volume and complications
    Chambers, N. A.
    Ramgolam, A.
    Sommerfield, D.
    Zhang, G.
    Ledowski, T.
    Thurm, M.
    Lethbridge, M.
    Hegarty, M.
    von Ungern-Sternberg, B. S.
    ANAESTHESIA, 2018, 73 (02) : 160 - 168
  • [40] A comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine
    Bharti, Neerja
    Arora, Suman
    Panda, Nidhi B.
    SAUDI JOURNAL OF ANAESTHESIA, 2014, 8 (02) : 188 - 192