The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study

被引:7
|
作者
Tonin, Bruna S. H. [1 ]
Fu, Jing [2 ]
He, Yiting [3 ]
Ye, Ning [4 ]
Chew, Hooi Pin [4 ]
Fok, Alex [4 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, Ribeirao Preto, SP, Brazil
[2] Qingdao Univ, Sch Stomatol, Dept Prosthodont, Affiliated Hosp, Qingdao, Peoples R China
[3] Sun Yat Sen Univ, Hosp Stomatol, Dept Prosthodont, Guangdong Prov Key Lab Stomatol, Guangzhou, Guangdong, Peoples R China
[4] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN 55455 USA
关键词
Finite element analysis; Bending moments; Implant -supported dental prosthesis; Prosthodontics; Computer -aided design; Computer -assisted manufacture; LOAD FATIGUE PERFORMANCE; ALL-CERAMIC CROWNS; ZIRCONIA ABUTMENTS; STRESS-DISTRIBUTION; BENDING MOMENTS; TITANIUM; RESTORATIONS; CONNECTIONS; FAILURE;
D O I
10.1016/j.jmbbm.2023.105847
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study aimed to evaluate the stress distribution and microgap formation in implant assemblies with conical abutments made of different materials under an oblique load.Materials and methods: The mechanical behavior of an implant assembly with a titanium abutment was analyzed and compared with that of an assembly with a Y-TZP abutment using finite element analysis (FEA). A torque of 20 Ncm was first applied to the abutment screw, followed by oblique loads of 10 N-280 N applied to the prosthesis placed on the implant. The maximum stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated.Results: No significant difference in stress distribution between the two cases was observed, with the stresses being mainly concentrated at the top half of the screw (the predicted maximum von Mises stress was approxi-mately 1200 MPa at 280 N). The area in contact at the implant-to-abutment interface decreased with increasing load for both abutments, with the critical load for bridging the internal implant space being roughly 140 N. The maximum gap size being was approximately 470 mu m with either abutment.Conclusion: There was no significant difference in the stress distribution or microgap formed between implant assemblies with titanium and Y-TZP abutments having an internal conical connection.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Effect of abutment angulation on the strain on the bone around an implant in the anterior maxilla: A finite element study
    Saab, Xavier E.
    Griggs, Jason A.
    Powers, John M.
    Engelmeier, Robert L.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (02): : 85 - 92
  • [32] Effect of crown stiffness and prosthetic screw absence on the stress distribution in implant-supported restoration: A 3D finite element analysis
    Epifania, Ettore
    di Lauro, Alessandro
    Ausiello, Pietro
    Mancone, Alessia
    Garcia-Godoy, Franklin
    Tribst, Joao Paulo Mendes
    PLOS ONE, 2023, 18 (05):
  • [33] Comparative Biomechanical Evaluation of Novel Screwless Retained Dental Implant Prosthesis: A 3D Finite Element Analysis
    Lee, Ki-Sun
    Kim, Jaeyeol
    Lim, Jaehyung
    Ryu, Jae-Jun
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2025, 16 (02)
  • [34] The effect of dental restoration geometry and material properties on biomechanical behaviour of a treated molar tooth: A 3D finite element analysis
    Babaei, Behzad
    Shouha, Paul
    Birman, Victor
    Farrar, Paul
    Prentice, Leon
    Prusty, Gangadhara
    Journal of the Mechanical Behavior of Biomedical Materials, 2022, 125
  • [35] The effect of dental restoration geometry and material properties on biomechanical behaviour of a treated molar tooth: A 3D finite element analysis
    Babaei, Behzad
    Shouha, Paul
    Birman, Victor
    Farrar, Paul
    Prentice, Leon
    Prusty, Gangadhara
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 125
  • [36] 3D finite element modelling of a carpometacarpal implant coated with hydroxyapatite
    Lbath, F
    Rumelhart, C
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 447 - 454
  • [37] Effect of platform switching on peri-implant bone: A 3D finite element analysis
    Aslam, Ayesha
    Hassan, Syed Hammad
    Aslam, Hammad Mudasser
    Khan, Danish Azeem
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06): : 935 - 940
  • [38] 3D finite-element simulation of material flow
    Biba, Nikolai
    Stebounov, Sergei
    Metallurgia, 2002, 69 (02):
  • [39] The effect of nucleus implant modulus on the mechanical behavior of lumbar functional spinal unit: A finite element study
    Joshi, A
    Karduna, A
    Marcolongo, M
    PROCEEDINGS OF THE IEEE 29TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2003, : 176 - 177
  • [40] Mechanical Influence of Edentulous Mandible Morphology on Peri-implant Bone in Implant Prosthetics: 3D Finite Element Analysis
    Hamada, Takumi
    Gonda, Tomoya
    Murase, Kohei
    Maeda, Yoshinobu
    Ikebe, Kazunori
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : 931 - 937