The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study

被引:7
|
作者
Tonin, Bruna S. H. [1 ]
Fu, Jing [2 ]
He, Yiting [3 ]
Ye, Ning [4 ]
Chew, Hooi Pin [4 ]
Fok, Alex [4 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, Ribeirao Preto, SP, Brazil
[2] Qingdao Univ, Sch Stomatol, Dept Prosthodont, Affiliated Hosp, Qingdao, Peoples R China
[3] Sun Yat Sen Univ, Hosp Stomatol, Dept Prosthodont, Guangdong Prov Key Lab Stomatol, Guangzhou, Guangdong, Peoples R China
[4] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN 55455 USA
关键词
Finite element analysis; Bending moments; Implant -supported dental prosthesis; Prosthodontics; Computer -aided design; Computer -assisted manufacture; LOAD FATIGUE PERFORMANCE; ALL-CERAMIC CROWNS; ZIRCONIA ABUTMENTS; STRESS-DISTRIBUTION; BENDING MOMENTS; TITANIUM; RESTORATIONS; CONNECTIONS; FAILURE;
D O I
10.1016/j.jmbbm.2023.105847
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study aimed to evaluate the stress distribution and microgap formation in implant assemblies with conical abutments made of different materials under an oblique load.Materials and methods: The mechanical behavior of an implant assembly with a titanium abutment was analyzed and compared with that of an assembly with a Y-TZP abutment using finite element analysis (FEA). A torque of 20 Ncm was first applied to the abutment screw, followed by oblique loads of 10 N-280 N applied to the prosthesis placed on the implant. The maximum stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated.Results: No significant difference in stress distribution between the two cases was observed, with the stresses being mainly concentrated at the top half of the screw (the predicted maximum von Mises stress was approxi-mately 1200 MPa at 280 N). The area in contact at the implant-to-abutment interface decreased with increasing load for both abutments, with the critical load for bridging the internal implant space being roughly 140 N. The maximum gap size being was approximately 470 mu m with either abutment.Conclusion: There was no significant difference in the stress distribution or microgap formed between implant assemblies with titanium and Y-TZP abutments having an internal conical connection.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effects of abutment screw preload in two implant connection systems: A 3D finite element study
    Jung, Won-kyung
    Lee, Won-sup
    Kwon, Ho-Beom
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05): : 474.e1 - 474.e8
  • [2] Effect of implant placement depth on bone remodeling on implant-supported single zirconia abutment crown: A 3D finite element study
    Poovarodom, Pongsakorn
    Rungsiyakull, Chaiy
    Suriyawanakul, Jarupol
    Li, Qing
    Sasaki, Keiichi
    Yoda, Nobuhiro
    Rungsiyakull, Pimduen
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (02) : 278 - 287
  • [3] A 3D Nonlinear Finite Element Study on Biomechanical Behavior of Dental Implants
    Wu, Ting
    Liao, Wenhe
    Dai, Ning
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 3263 - 3267
  • [4] Effect of material and dimensions on the mechanical behavior of a dental implant
    Hedia, Hassan S.
    Najjar, Ismail M. R.
    Fouda, Noha
    Al-Thobiani, Fisal W.
    Timraz, Hattan A.
    MATERIALS TESTING, 2020, 62 (08) : 775 - 782
  • [5] Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading
    Mishra, Manish
    Ozawa, Shogo
    Masuda, Tatsuhiko
    Yoshioka, Fumi
    Tanaka, Yoshinobu
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (03): : 140 - 144
  • [6] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [7] Effect of abutment type and creep behavior on the mechanical properties of implant restorations in the anterior region: A finite element analysis
    Anniwaer, Annikaer
    Yin, Zhengrong
    Zhu, Jiakang
    Huang, Cui
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 : 93 - 102
  • [8] Influence of Framework Material and Abutment Configuration on Fatigue Performance in Dental Implant Systems: A Finite Element Analysis
    Erdogdu, Meryem
    Demirel, Mehmet Goekberkkaan
    Mohammadi, Reza
    Guentekin, Neslihan
    Chaleshtori, Masoud Ghanbarzadeh
    MEDICINA-LITHUANIA, 2024, 60 (09):
  • [9] Biomechanical analysis and comparison of 12 dental implant systems using 3D finite element study
    Liang, Rui
    Guo, Weihua
    Qiao, Xiangchen
    Wen, Hailin
    Yu, Mei
    Tang, Wei
    Liu, Lei
    Wei, Yongtao
    Tian, Weidong
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (12) : 1340 - 1348
  • [10] 3D finite element analysis of an all-zirconia dental implant rehabilitation
    Correia, A.
    Reis Campos, J. C.
    Ramos, N. V.
    Vaz, M.
    Couto Viana, J. P.
    Kovacs, Z.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 361 - 363