Optimization analysis of Organic Rankine Cycle powered by waste heat of a supermarket transcritical CO2 multi-ejector refrigeration cycle

被引:9
|
作者
Tsimpoukis, Dimitrios [1 ,2 ]
Syngounas, Evangelos [1 ]
Bellos, Evangelos [3 ]
Koukou, Maria [4 ]
Tzivanidis, Christos [3 ]
Anagnostatos, Stavros [2 ,5 ]
Vrachopoulos, Michail Gr [4 ]
机构
[1] Natl & Kapodistrian Univ Athens, Core Dept, Energy & Environm Res Lab, Psachna, Greece
[2] METRO SA, Energy Environm & Facil Dept, Head Dept Dev, Athens, Greece
[3] Natl Tech Univ Athens, Sch Mech Engn, Thermal Dept, Athens, Greece
[4] Natl & Kapodistrian Univ Athens, Dept Agr Dev, Agrofood & Management Nat Resources, Psachna, Greece
[5] Natl Tech Univ Athens, Sch Elect Engn, Elect Power Dept, Athens, Greece
关键词
Refrigeration; Power production; ORC; Waste heat; CO2; PERFORMANCE; RECOVERY; ENERGY; ORC;
D O I
10.1016/j.jclepro.2023.138106
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The exploitation of low-grade heat sources that are available from existing thermal systems processes consists a promising concept for the production of energy. In this research, the integration of an Organic Rankine Cycle (ORC) unit on a supermarket transcritical CO2 refrigeration system with ejectors is investigated, which is supplied with low-grade heat by the common discharge of the compressors. The optimization analysis proves that for different combinations of CO2 temperature and pressure in the ORC evaporator, as well as for different ORC condensation temperatures, there is a different optimum ORC evaporation temperature that leads to the highest energy production. Concerning the annual performance analysis conducted for the city of Athens, Greece, operation with isopentane is found to provide the greatest energy production with 10.36 MWh annually, which corresponds to a 3.69% reduction in the refrigeration system's energy consumption. For operation under the ambient temperature of 40 degrees C, the corresponding reduction of the refrigeration system consumption due to the presence of ORC is 7.54%. Finally, the financial analysis reveals that toluene is the most advantageous solution, leading to a payback period of 3.9 years, with a net present value by the end of the project's lifetime equal to 34.32 keuro.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental analysis on the effect of internal heat exchanger in transcritical CO2 refrigeration cycle with two-phase ejector
    Nakagawa, Masafumi
    Marasigan, Ariel R.
    Matsukawa, Takanori
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1577 - 1586
  • [32] A comprehensive comparison between CO2 and Ethane as a refrigerant in a two-stage ejector-expansion transcritical refrigeration cycle integrated with an organic Rankine cycle (ORC)
    Nemati, Arash
    Mohseni, Roya
    Yari, Mortaza
    JOURNAL OF SUPERCRITICAL FLUIDS, 2018, 133 : 494 - 502
  • [34] TRANSCRITICAL CO2 HEAT PUMP WITH EXPANDER-EJECTOR CYCLE
    Sit, B.
    Timcenco, D.
    Sit, M.
    PROBLEMELE ENERGETICII REGIONALE, 2010, (01): : 75 - 80
  • [35] Preliminary investigation of a transcritical CO2 heat pump driven by a solar-powered CO2 Rankine cycle
    Li, Xiao-Juan
    Zhang, Xin-Rong
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (11) : 1361 - 1371
  • [36] A transcritical carbon dioxide power cycle enhanced by ejector refrigeration for engine waste heat recovery: Comprehensive analysis and optimization
    Wu, Chuang
    Wan, Yuke
    Xu, Xiaoxiao
    Liu, Chao
    ENERGY CONVERSION AND MANAGEMENT, 2023, 292
  • [37] Experimental investigation on the performance of a transcritical CO2 heat pump with multi-ejector expansion system
    Boccardi, G.
    Botticella, F.
    Lillo, G.
    Mastrullo, R.
    Mauro, A. W.
    Trinchieri, R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 389 - 400
  • [38] Performance Analysis of Coupled System of CO2 Transcritical Heat Pump and Rankine Cycle
    Wang, Hongli
    Tian, Jingrui
    Ma, Yitai
    Hou, Xiujuan
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1860 - +
  • [39] Exergoeconomic analysis of CO2 transcritical refrigeration cycle system
    Yang, Junlan
    Gao, Siyu
    Li, Jiudong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (01): : 60 - 65
  • [40] Thermodynamic analysis of a modified two-stage transcritical CO2 refrigeration cycle with an ejector and a subcooler
    Li, Huanmin
    Huang, Qiuyue
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 168 : 492 - 505