Impact of buoyant jet entrainment on the thermocline behavior in a single-medium thermal energy storage tank

被引:10
|
作者
Lou, Wanruo [1 ]
Baudin, Nicolas [1 ]
Fan, Yilin [1 ]
Luo, Lingai [1 ]
机构
[1] Nantes Univ, CNRS, Lab therm & energie Nantes, LTeN,UMR 6607, F-44000 Nantes, France
关键词
Thermal energy storage (TES); Single-medium thermocline (SMT); Jet entrainment; Flow distributor; Particle Image Velocimetry (PIV); Temperature stratification; HOT-WATER TANK; NUMERICAL-SIMULATION; STRATIFICATION; PERFORMANCE; INLET; EFFICIENCY; STABILITY; DYNAMICS; MODELS; NUMBER;
D O I
10.1016/j.est.2023.108017
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the characterization and management of dynamic thermocline behaviors in a single-medium thermocline (SMT) thermal energy storage tank with the aim of its performance improvement. In particular, the flow mixing induced by the entering thermal jet, its impact on the temperature stratification and its mitigation measure are systematically explored by both numerical and experimental methods. Results of CFD simulation and Particle Image Velocimetry (PIV) visualization clearly demonstrate the jet entrainment phenomenon and the typical flow patterns featured by the rising buoyant plumes. For the storage tank with simple inlet port, this thermal jet would cause the thermal overturning, the strong fluid mixing and convection heat transfer, resulting in the degradation of temperature stratification and the thermocline decay (Ri(gradient) < 0.25 at certain positions of the tank). It has also been shown by PIV measurement that the impact of thermal jet, characterized by the jet penetration length, becomes stronger with the increasing injecting flow rate and with the decreasing temperature difference between the injecting and existing fluids. Orifice baffle-type distributor has then been proposed and optimized, showing clearly its effectiveness for mitigating the impact of thermal jet on the temperature stratification. Both the initial uniform orifice baffle and the optimized orifice baffle distributors are then fabricated and installed into a lab-scale cuboid SMT storage tank. Charging operations are performed under different inlet flow rates (Qin: 0.3 to 1.5 L center dot min(-1)) and temperature differences between hot and cold fluids (Delta T: 30 to 50 K). Experimental results obtained show that the optimized distributor could always lead to the better thermal performance (capacity ratio up to 0.94 and charging efficiency up to 0.8) than the initial uniform baffle distributor, providing more flexible operating conditions of the SMT storage systems in different industrial sectors.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Thermal characteristics of the high-temperature molten-salt heat storage process with a thermocline in single tank
    Yin, Huibin
    Ding, Jing
    Yang, Xiaoxi
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (26): : 68 - 74
  • [32] Assessing the impact of a novel hemispherical diffuser on a single-tank sensible thermal energy storage system
    Parida, Dipti Ranjan
    Advaith, S.
    Dani, Nikhil
    Basu, Saptarshi
    RENEWABLE ENERGY, 2022, 183 : 202 - 218
  • [33] Simplified dynamic modeling of single-tank thermal energy storage systems
    Raccanello, J.
    Rech, S.
    Lazzaretto, A.
    ENERGY, 2019, 182 : 1154 - 1172
  • [34] Thermal and economic evaluation of thermocline combined sensible-latent heat thermal energy storage system for medium temperature applications
    Ahmed, N.
    Elfeky, K. E.
    Lu, Lin
    Wang, Q. W.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 189 (14-23) : 14 - 23
  • [35] An efficient tank size estimation strategy for packed-bed thermocline thermal energy storage systems for concentrated solar power
    Zhao, Bingchen
    Cheng, Maosong
    Liu, Chang
    Dai, Zhimin
    SOLAR ENERGY, 2017, 153 : 104 - 114
  • [36] Numerical Research on Thermodynamic Properties of a Thermocline in Thermal Energy Storage Tank Based on Modified One-Dimensional Dimensionless Model
    Ju, Haoran
    Zheng, Lijun
    Zhong, Wei
    ENERGIES, 2023, 16 (22)
  • [37] Experimental Test of Characterization of an Innovative Thermal Energy Storage System Based on Low Melting Molten Salt Thermocline Tank Integrated with an Oil Exchanger
    Gaggioli, Walter
    Liberatore, Raffaele
    Di Ascenzi, Primo
    Mazzei, Domenico
    Russo, Valeria
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2019), 2020, 2303
  • [38] Performance comparison of two-tank direct and thermocline thermal energy storage systems for 1 MWe class concentrating solar power plants
    Cocco, Daniele
    Serra, Fabio
    ENERGY, 2015, 81 : 526 - 536
  • [39] Impact of pressure on the dynamic behavior of CO2 hydrate slurry in a stirred tank reactor applied to cold thermal energy storage
    Dufour, Thomas
    Hong Minh Hoang
    Oignet, Jeremy
    Osswald, Veronique
    Clain, Pascal
    Fournaison, Laurence
    Delahaye, Anthony
    APPLIED ENERGY, 2017, 204 : 641 - 652
  • [40] Comparative research of heat discharging characteristic of single tank molten salt thermal energy storage system
    Zhang, Cancan
    Lu, Yuanwei
    Shi, Suli
    Wu, Yuting
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 161