Effects of Air Vent Size and Location Design on Air Supply Efficiency in Flood Discharge Tunnel Operations

被引:48
|
作者
Wei, Wangru [1 ]
Gong, Jing [1 ]
Deng, Jun [1 ]
Xu, Weilin [1 ]
机构
[1] Sichuan Univ, State Key Lab Hydraul & Mt River Engn, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
Flood discharge tunnel; Air supply; Ventilation design; High dam project; CONSTRUCTION; PRESSURE; DEMAND; SOUND; NOISE;
D O I
10.1061/JHEND8.HYENG-13305
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Low-level outlets are essential flood discharge structures for high-head dams. High-speed free-surface flows releasing into tunnels lead to substantial air discharge, and the air supply is important for gate vibration mitigation, cavitation protection by aeration, and slug flow transition phenomena. An additional challenge is the excessive wind noise due to low air supply efficiency, threatening staff working conditions in flood discharge operations. However, the current understanding of the effects of air vent sizes and locations on the air supply efficiency is still limited. In the present study, based on a series of experimental tests, air vent designs of long flood discharge tunnels, including a single vent and two combined working vents, are analyzed with respect to the air discharge variation. For air vent designs with a small vent size and an installation location downstream, the air discharge into the tunnel is low, and the air supply efficiency is low even for two combined working vents. Equations for the air supply efficiency are proposed, which enables quantifying the ventilation performance, and related vent parameters are recommended for favorable air ventilation designs. The present investigation provides a reference for the flood discharge tunnel design and ventilation operation assessment in hydraulic engineering. Air ventilation design is an important part of flood discharge tunnels and water supply and drainage systems. The single air vent sizes, locations, and combined working vents are considered in the present studies. The single air vent sizes, air vent downstream locations, and two vent distances are effect factors, providing reasonable assessment methods to predict the air supply efficiency for different structural and hydraulic conditions. A reasonable hydraulic design can obtain high air supply efficiency and regulate air discharge distributions in multiple air vents. The guidelines in the present analyses are effective to optimize the multiple air ventilation system and to obtain safety operations and acceptable staff working conditions.
引用
收藏
页数:12
相关论文
共 39 条
  • [21] Exploring the Effects of Particle Size Distribution and Gap Distance on a Nanosecond Pulsed Discharge in Air with Fluorapatite Microparticles
    Diamond, James
    Hamdan, Ahmad
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2023, 43 (05) : 1059 - 1075
  • [22] Exploring the Effects of Particle Size Distribution and Gap Distance on a Nanosecond Pulsed Discharge in Air with Fluorapatite Microparticles
    James Diamond
    Ahmad Hamdan
    Plasma Chemistry and Plasma Processing, 2023, 43 : 1059 - 1075
  • [23] Effects of ceiling exhaust location on thermal comfort and age of air in room under impinging jet supply scheme
    Qin, Chao
    Lu, Wei-Zhen
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [24] Optimization of air supply location, size, and parameters in enclosed environments using a computational fluid dynamics-based adjoint method
    Liu, Wei
    Jin, Mingang
    Chen, Chun
    Chen, Qingyan
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2016, 9 (02) : 149 - 161
  • [25] Effects of Fire Location and Forced Air Volume on Fire Development for Single-Ended Tunnel Fire with Forced Ventilation
    Zhao, Jinlong
    Wang, Zhenhua
    Hu, Zhenqi
    Cui, Xinyuan
    Peng, Xiandu
    Zhang, Jianping
    FIRE-SWITZERLAND, 2023, 6 (03):
  • [26] Prompt design of the air-supply opening size for a commercial airplane based on the proper orthogonal decomposition of flows
    Wei, Yun
    Zhang, Tengfei
    Wang, Shugang
    BUILDING AND ENVIRONMENT, 2016, 96 : 131 - 141
  • [27] High pressure air spray assistant power supply control strategies and their effects on diesel engine under transient operations
    Han Y.
    Liu Z.
    Wang Z.
    Zhu R.
    Frontiers of Energy and Power Engineering in China, 2007, 1 (3): : 295 - 299
  • [28] Effects of air distribution and refractory arch design on efficiency of coal fired travelling grate boilers
    Ji, J. J.
    Luo, Y. H.
    Lin, P. Y.
    JOURNAL OF THE ENERGY INSTITUTE, 2007, 80 (04) : 214 - 222
  • [29] An Experimental and Theoretical Investigation of the Effects of Supply Air Conditions on Computational Efficiency in Data Centers Employing Aisle Containment
    Tatchell-Evans, Morgan
    Burdett, Daniel
    Summers, Jonathan
    Beaumont, Adam
    Fox, Geoff
    2017 THIRTY-THIRD ANNUAL SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2017, : 100 - 107
  • [30] REMOVAL OF FINE PARTICLES FROM WATER BY DISPERSED AIR FLOTATION - EFFECTS OF BUBBLE SIZE AND PARTICLE-SIZE ON COLLECTION EFFICIENCY
    REAY, D
    RATCLIFF, GA
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1973, 51 (02): : 178 - 185