Prevalence of Cochlear Nerve Deficiency and Hearing Device Use in Children With Single-Sided Deafness

被引:6
|
作者
Ward, Kristina M. [1 ,2 ,3 ]
Coughran, Alanna J. [2 ]
Lee, Monterosa [2 ]
Fitzgerald, Matthew B. [2 ]
Cheng, Alan G. [2 ]
Chang, Kay W. [2 ]
Ahmad, Iram N. [2 ]
机构
[1] Stanford Med Childrens Hlth, Dept Pediat Audiol, Palo Alto, CA USA
[2] Stanford Univ, Dept Otolaryngol Head & Neck Surg, Sch Med, Palo Alto, CA USA
[3] Stanford Univ, Dept Otolaryngol Head & Neck Surg, Sch Med, 2452 Watson Court,Suite 1700, Palo Alto, CA 94303 USA
关键词
children; cochlear implant; cochlear nerve deficiency; single-sided deafness; BONE-ANCHORED HEARING; COMPUTED-TOMOGRAPHY; AMPLIFICATION; IMPLANTATION; REHABILITATION; ETIOLOGY; OUTCOMES; SPEECH;
D O I
10.1002/ohn.255
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
ObjectiveThis study aimed to assess the prevalence of cochlear nerve deficiency (CND) in a cohort of pediatric patients with single-sided deafness (SSD). A secondary objective was to investigate trends in intervention and hearing device use in these children. Study DesignCase series with chart review. SettingPediatric tertiary care center. MethodsChildren ages 0 to 21 years with SSD (N = 190) who underwent computerized tomography (CT) and/or magnetic resonance imaging (MRI) were included. Diagnostic criteria for SSD included unilateral severe-to-profound sensorineural hearing loss with normal hearing sensitivity in the contralateral ear. Diagnostic criteria for CND included neuroradiologist report of an "aplastic or hypoplastic nerve" on MRI or a "stenotic cochlear aperture" on CT. ResultsThe prevalence of CND was 42% for children with CT only, 76% for children with MRI only, and 63% for children with both MRI and CT. Of the children with MRI and CT, there was a 90% concordance across imaging modalities. About 36% of children with SSD had hearing devices that routed sound to the normal hearing ear (ie, bone conduction hearing device/contralateral routing of signal), while only 3% received a cochlear implant. Approximately 40% did not have a hearing device. Hearing device wear time averaged 2.9 hours per day and did not differ based on cochlear nerve status. ConclusionThere is a high prevalence of CND in children with SSD. Cochlear nerve status should be confirmed via MRI in children with SSD. The limited implementation and use of hearing devices observed for children with SSD reinforce the need for increased support for early and continuous intervention.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 50 条
  • [21] Editorial: Binaural Hearing with Cochlear Implants for Bilateral, Bimodal, and Single-Sided Deafness Patients
    Aronoff, Justin
    Hughes, Michelle
    EAR AND HEARING, 2016, 37 (03): : 247 - 247
  • [22] Quality standards for adult cochlear implantation in single-sided deafness and asymmetric hearing loss
    Tavora-Vieira, Dayse
    Rajan, Gunesh
    Van de Heyning, Paul
    Mertens, Griet
    B-ENT, 2020, 16 (04): : 209 - 216
  • [23] Health Insurance Coverage of Cochlear Implantation in Single-Sided Deafness and Asymmetric Hearing Loss
    Sorkin, Donna L.
    Adunka, Oliver F.
    Westin, Nichole
    OTOLOGY & NEUROTOLOGY, 2023, 44 (08) : E628 - E634
  • [24] Cochlear Implantation in Sporadic Intralabyrinthine Schwannomas with Single-Sided Deafness: Implications for Binaural Hearing
    West, Niels
    Sorensen, Rikke Skovhoj
    Kressner, Abigail Anne
    Bille, Michael
    Marozeau, Jeremy
    Caye-Thomasen, Per
    OTOLOGY & NEUROTOLOGY, 2024, 45 (02) : 128 - 135
  • [25] Cost Effectiveness of Cochlear Implantation in Single-Sided Deafness
    Dreyfuss, Michael
    Giat, Yahel
    Veraguth, Dorothe
    Roosli, Christof
    Huber, Alexander M.
    Laske, Roman D.
    OTOLOGY & NEUROTOLOGY, 2021, 42 (08) : 1129 - 1135
  • [26] Cochlear implantation in a child with posttraumatic single-sided deafness
    Plontke, Stefan K.
    Heider, Cornelia
    Koesling, Sabrina
    Hess, Soeren
    Bieseke, Lars
    Goetze, Gerrit
    Rahne, Torsten
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (05) : 1757 - 1761
  • [27] Audiological results with cochlear implants for single-sided deafness
    Jacob, R.
    Stelzig, Y.
    Nopp, P.
    Schleich, P.
    HNO, 2011, 59 (05) : 453 - 460
  • [28] Cochlear implantation for single-sided deafness and tinnitus suppression
    Holder, Jourdan T.
    O'Connell, Brendan
    Hedley-Williams, Andrea
    Wanna, George
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2017, 38 (02) : 226 - 229
  • [29] Cochlear Implantation for Single-Sided Deafness: A Multicenter Study
    Sladen, Douglas P.
    Frisch, Christopher D.
    Carlson, Matthew L.
    Driscoll, Colin L. W.
    Torres, Jennifer H.
    Zeitler, Daniel M.
    LARYNGOSCOPE, 2017, 127 (01): : 223 - 228
  • [30] Cochlear implantation in a child with posttraumatic single-sided deafness
    Stefan K. Plontke
    Cornelia Heider
    Sabrina Koesling
    Sören Hess
    Lars Bieseke
    Gerrit Goetze
    Torsten Rahne
    European Archives of Oto-Rhino-Laryngology, 2013, 270 : 1757 - 1761