Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study

被引:4
|
作者
Fu, Shuang [1 ,2 ]
Sun, Wei [2 ]
Zhu, Jingxian [1 ,2 ]
Huang, Bin [2 ]
Ji, Wei [1 ,2 ]
Shi, Bin [1 ,2 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, State Key Lab Oral & Maxillofacial Reconstruct & R, Key Lab Oral Biomed,Minist Educ,Hubei Key Lab Stom, Wuhan, Peoples R China
[2] Wuhan Univ, Sch & Hosp Stomatol, Dept Implantol, Wuhan, Peoples R China
关键词
Fully edentulous; Computer-assisted implant surgery; Accuracy; REPORTED OUTCOME MEASURES; SURGICAL GUIDES; PLACEMENT; NAVIGATION; TEMPLATE; ERRORS;
D O I
10.1007/s00784-023-05161-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to compare implant positioning accuracy and patient-centered results between static and dynamic computer-assisted implant surgery (s-CAIS and d-CAIS) in edentulous jaws. Material and methods The current study retrospectively evaluated a total of 110 implants placed in 22 fully edentulous patients via s-CAIS or d-CAIS (n = 11). The accuracy of implant positioning was assessed by measuring the implant's angular deviation and deviation at the platform and apex from the preoperative design postoperatively. Patient-centered results, including preoperative and intraoperative patient-reported experiences and postoperative patient-reported outcomes, were extracted from the medical records. The nested t test and chi-square test were used to compare accuracy and patient-centered results between s-CAIS and d-CAIS postoperatively. Results The implants in the s-CAIS group showed significantly smaller angular deviation (2.32 +/- 1.23 degrees) than those in the d-CAIS group (3.87 +/- 2.75 degrees). In contrast, the platform and apical deviation were significantly larger in s-CAIS (1.56 +/- 1.19 mm and 1.70 +/- 1.09 mm, respectively) than d-CAIS (1.02 +/- 0.45 mm and 1.00 +/- 0.51 mm, respectively). Furthermore, the implants in the s-CAIS group deviated significantly (p < 0.001) more toward the coronal direction than those in the d-CAIS group. Notably, all patients in the s-CAIS group reported an obvious foreign body sensation during surgery, representing a significant difference from the d-CAIS group. Conclusions Compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation and less foreign body sensation. Trial registration. The retrospective study was registered on the Chinese Clinical Trial Registry on August 8th, 2022, with registration number No. ChiCTR2200062484. Clinical relevance Despite the increasing use of computer- assisted implant surgery in fully edentulous patients, clinical evidence comparing implant positioning accuracy and patient-centered results between static and dynamic CAIS systems is scarce. Our study demonstrated that compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation.
引用
收藏
页码:5427 / 5438
页数:12
相关论文
共 50 条
  • [21] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348
  • [22] Influence of guide support on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous cases using a keyless guiding system: an in vitro study
    David Kasradze
    Ricardas Kubilius
    BMC Oral Health, 25 (1)
  • [23] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Gargallo-Albiol, Jordi
    Jose Zilleruelo-Pozo, Maria
    Lucas-Taule, Ernest
    Munoz-Penalver, Jesus
    Paternostro-Betancourt, Daniel
    Hernandez-Alfaro, Federico
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (03) : 2783 - 2791
  • [24] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Jordi Gargallo-Albiol
    María José Zilleruelo-Pozo
    Ernest Lucas-Taulé
    Jesús Muñoz-Peñalver
    Daniel Paternostro-Betancourt
    Federico Hernandez-Alfaro
    Clinical Oral Investigations, 2022, 26 : 2783 - 2791
  • [25] Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery
    El Kholy, Karim
    Lazarin, Rafael
    Janner, Simone F. M.
    Faerber, Karin
    Buser, Ramona
    Buser, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (11) : 1067 - 1075
  • [26] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23
  • [27] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)
  • [28] Accuracy of implant placement with a combined use of static and dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial
    Yotpibulwong, Thanida
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Sinpitaksakul, Phonkit
    Arksornnukit, Mansuang
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (04) : 330 - 341
  • [29] The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial
    Kaewsiri, Dechawat
    Panmekiate, Soontra
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (06) : 505 - 514
  • [30] Is there a learning curve in static computer-assisted implant surgery? A prospective clinical study
    Cassetta, M.
    Altieri, F.
    Giansanti, M.
    Bellardini, M.
    Brandetti, G.
    Piccoli, L.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (10) : 1335 - 1342