Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study

被引:4
|
作者
Fu, Shuang [1 ,2 ]
Sun, Wei [2 ]
Zhu, Jingxian [1 ,2 ]
Huang, Bin [2 ]
Ji, Wei [1 ,2 ]
Shi, Bin [1 ,2 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, State Key Lab Oral & Maxillofacial Reconstruct & R, Key Lab Oral Biomed,Minist Educ,Hubei Key Lab Stom, Wuhan, Peoples R China
[2] Wuhan Univ, Sch & Hosp Stomatol, Dept Implantol, Wuhan, Peoples R China
关键词
Fully edentulous; Computer-assisted implant surgery; Accuracy; REPORTED OUTCOME MEASURES; SURGICAL GUIDES; PLACEMENT; NAVIGATION; TEMPLATE; ERRORS;
D O I
10.1007/s00784-023-05161-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to compare implant positioning accuracy and patient-centered results between static and dynamic computer-assisted implant surgery (s-CAIS and d-CAIS) in edentulous jaws. Material and methods The current study retrospectively evaluated a total of 110 implants placed in 22 fully edentulous patients via s-CAIS or d-CAIS (n = 11). The accuracy of implant positioning was assessed by measuring the implant's angular deviation and deviation at the platform and apex from the preoperative design postoperatively. Patient-centered results, including preoperative and intraoperative patient-reported experiences and postoperative patient-reported outcomes, were extracted from the medical records. The nested t test and chi-square test were used to compare accuracy and patient-centered results between s-CAIS and d-CAIS postoperatively. Results The implants in the s-CAIS group showed significantly smaller angular deviation (2.32 +/- 1.23 degrees) than those in the d-CAIS group (3.87 +/- 2.75 degrees). In contrast, the platform and apical deviation were significantly larger in s-CAIS (1.56 +/- 1.19 mm and 1.70 +/- 1.09 mm, respectively) than d-CAIS (1.02 +/- 0.45 mm and 1.00 +/- 0.51 mm, respectively). Furthermore, the implants in the s-CAIS group deviated significantly (p < 0.001) more toward the coronal direction than those in the d-CAIS group. Notably, all patients in the s-CAIS group reported an obvious foreign body sensation during surgery, representing a significant difference from the d-CAIS group. Conclusions Compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation and less foreign body sensation. Trial registration. The retrospective study was registered on the Chinese Clinical Trial Registry on August 8th, 2022, with registration number No. ChiCTR2200062484. Clinical relevance Despite the increasing use of computer- assisted implant surgery in fully edentulous patients, clinical evidence comparing implant positioning accuracy and patient-centered results between static and dynamic CAIS systems is scarce. Our study demonstrated that compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation.
引用
收藏
页码:5427 / 5438
页数:12
相关论文
共 50 条
  • [1] Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study
    Shuang Fu
    Wei Sun
    Jingxian Zhu
    Bin Huang
    Wei Ji
    Bin Shi
    Clinical Oral Investigations, 2023, 27 : 5427 - 5438
  • [2] The accuracy of dynamic computer assisted implant surgery in fully edentulous jaws: A retrospective case series
    Wang, Jiayi
    Ge, Yanjun
    Muhlemann, Sven
    Pan, Shaoxia
    Jung, Ronald E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (11) : 1278 - 1288
  • [3] In Vivo and In Vitro Accuracy Analysis of Static Computer-Assisted Implant Surgery in an Edentulous Patient
    Makarov, Nikolay
    Papi, Piero
    Santomauro, Vincenzo
    Di Carlo, Gabriele
    Polimeni, Antonella
    Di Murro, Bianca
    Saccucci, Matteo
    APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [4] Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
    Ruiz-Romero, Victor
    Jorba-Garcia, Adria
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    JOURNAL OF DENTISTRY, 2024, 149
  • [5] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853
  • [6] Accuracy and patient-centered results of marker-based and marker-free registrations for dynamic computer-assisted implant surgery: A randomized controlled trial
    Zhu, Jingxian
    Sun, Wei
    Li, Lei
    Li, Honglei
    Zou, Yujie
    Huang, Bin
    Ji, Wei
    Shi, Bin
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, : 101 - 113
  • [7] Dynamic and static computer-assisted implant surgery for completely edentulous patients. A proof of a concept
    Pomares-Puig, Carmen
    Sanchez-Garces, M. Angeles
    Jorba-Garcia, Adria
    JOURNAL OF DENTISTRY, 2023, 130
  • [8] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [9] Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study
    Li, Jun
    Dai, Meng
    Wang, Siwei
    Zhang, Xitao
    Fan, Qin
    Chen, Lin
    JOURNAL OF DENTISTRY, 2024, 148
  • [10] Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non- randomized prospective study
    Jaemsuwan, S.
    Arunjaroensuk, S.
    Kaboosaya, B.
    Subbalekha, K.
    Mattheos, N.
    Pimkhaokham, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (02) : 264 - 271