Influence of substrate material and geometric features of measurement slits on the measurement results of infrared optical system quality characteristics

被引:0
|
作者
Leonov, M. B. [1 ]
Terletskiy, E. S. [1 ]
Seregin, D. A. [1 ]
机构
[1] Kometa Corp Electro Opt Surveillance Syst, St Petersburg, Russia
关键词
LINE-SPREAD FUNCTION;
D O I
10.1364/JOT.90.000384
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subject of study. The influence of geometric characteristics and manufacturing technology, as well as the optical characteristics of their substrate material on the results of the line spread functions and modulation transfer measurements of long-wave infrared spectral range lenses, is studied. The aim of the study is to minimize the measurement error of these functions arising from measurement slit characteristics. Method. The theoretical computation method is used to determine the measurement error of the modulation transfer function arising from the geometrical characteristics of the measurement slits and pinhole. A practical computation method consisting of multiple measurements of the reference lens and a comparison between the measurement results and optical calcu-lations is applied to determine the measurement error of the line spread function and modulation transfer function of the reference lens, arising from the effect of the slit substrate material. Main results. The influence of the geo-metric features of the measurement slits and pinholes on the results of the line spread function and the modulation transfer function measurements is considered: the concept of the apparatus line spread function as a convolution of the true point spread function or line spread function with spatial functions of the measurement and object slits is defined. This study presents the construction of the calculation formulas of the absolute error to define the cor-rection coefficient for the finite size of the slits and pinholes used for evaluating the modulation transfer function according to the measured line spread functions. A reasonable error of the slit or pinhole size for the minimization of the modulation transfer function error is defined. The influence of the slit substrate materials (zinc selenide, calcium fluoride, and barium fluoride) as well as the metallic slit on the measurement results of the line spread function and the reference lens modulation transfer function is studied. The studies deduce that the results depend not only on the geometric features of the slit but also on the manufacturing technology and optical characteristics of their substrate material. Practical significance. Possible errors of the measurement slit manufacturing technology are considered. The recommendations on the optimization of the slit manufacturing technology on an infrared transparent substrate are presented. In the future, the above conclusions and recommendations will provide trace-ability of the measurements of the line spread function and the modulation transfer function of infrared optical systems in the optical industry. They will be useful to both measurement specialists and measurement equipment developers and manufacturers. (c) 2023 Optica Publishing Group
引用
收藏
页码:384 / 389
页数:6
相关论文
共 50 条
  • [31] A LASER SCANNER BASED MEASUREMENT SYSTEM FOR QUANTIFICATION OF CITRUS TREE GEOMETRIC CHARACTERISTICS
    Lee, K. H.
    Ehsani, R.
    APPLIED ENGINEERING IN AGRICULTURE, 2009, 25 (05) : 777 - 788
  • [32] An integrated measurement system for LED thermal, optical and electrical characteristics
    Zou Xiyong
    Zheng Xiaoming
    Jin Shangzhong
    Ni Kai
    Zhou Huaming
    He Xianqi
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2007: OPTOELECTRONIC SYSTEM DESIGN, MANUFACTURING, AND TESTING, 2008, 6624
  • [33] A Scattering Measurement System to Determine the Optical Characteristics of Industrial Suspensions
    Keranen, Ville T. J.
    Makynen, Anssi J.
    Prahl, Scott A.
    Tormanen, Matti
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 551 - +
  • [34] Experimental measurement and numerical simulation to determine characteristics of an infrared tube system
    Hassan, Samer A.
    HVAC&R RESEARCH, 2012, 18 (03): : 446 - 460
  • [35] Influence of Geometric Length Perturbation of Optical Path on Measurement Error of Seawater Refractive Index
    Zhang, Xinyi
    Zhao, Jiaxin
    Wang, Hu
    Li, Liyan
    Fan, Songtao
    Wang, Yongjie
    Zhou, Yan
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2025, 13 (03)
  • [36] Influence of Optical Power on Thermal Resistance Measurement for High Power Infrared Emitter
    Ching, Chin-Peng
    Devarajan, Mutharasu
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE), 2012, : 384 - 387
  • [37] The Influence of Material Electromagnetic Parameters on Results of Stress Measurement With Eddy Current Thermography
    Yang, Suixian
    Deng, Shuwen
    JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS, 2023, 6 (01):
  • [38] Hardware and software system for measuring the quality characteristics of infrared optical systems
    Leonov, M. B.
    Kupriyanov, I. A.
    Seregin, D. A.
    Churikov, S. S.
    Terletskiy, E. S.
    JOURNAL OF OPTICAL TECHNOLOGY, 2019, 86 (07) : 452 - 455
  • [39] Measurement system of optical properties of vertebra bones on near-infrared spectrum
    Li, Weitao
    Qian, Zhiyu
    Gao, Hui
    Xing, Lidong
    Song, Xiaofeng
    Cao, Xinzhi
    1ST INTERNATIONAL CONFERENCE ON ORANGE TECHNOLOGIES (ICOT 2013), 2013, : 111 - 114
  • [40] Method of focal length measurement for infrared optical system with long focal length
    Yao, Z. (yaozhen0492@163.com), 1950, Chinese Society of Astronautics (43):