Cumulative Neutral Loss Model for Fragment Deconvolution in Electrospray Ionization High-Resolution Mass Spectrometry Data

被引:3
|
作者
van Herwerden, Denice [2 ]
O'Brien, Jake W. [1 ,2 ]
Lege, Sascha [3 ]
Pirok, Bob W. J. [2 ]
Thomas, Kevin V. [1 ]
Samanipour, Saer [1 ,2 ,4 ]
机构
[1] Univ Queensland, Queensland Alliance Environm Hlth Sci QAEHS, Brisbane 4102, Australia
[2] Univ Amsterdam, Vant Hoff Inst Mol Sci HIMS, NL-1012 WX Amsterdam, Netherlands
[3] Agilent Technol Deutschland GmbH, D-76337 Waldbronn, Germany
[4] Univ Amsterdam, UvA Data Sci Ctr, NL-1012 WP Amsterdam, Netherlands
关键词
IDENTIFICATION; PLATFORM; WATER;
D O I
10.1021/acs.analchem.3c00896
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clean high-resolution mass spectra (HRMS) are essentialto a successfulstructural elucidation of an unknown feature during nontarget analysis(NTA) workflows. This is a crucial step, particularly for the spectragenerated during data-independent acquisition or during direct infusionexperiments. The most commonly available tools only take advantageof the time domain for spectral cleanup. Here, we present an algorithmthat combines the time domain and mass domain information to performspectral deconvolution. The algorithm employs a probability-basedcumulative neutral loss (CNL) model for fragment deconvolution. Theoptimized model, with a mass tolerance of 0.005 Da and a score(CNL) threshold of 0.00, was able to achieve a true positiverate (TPr) of 95.0%, a false discovery rate (FDr) of 20.6%, and areduction rate of 35.4%. Additionally, the CNL model was extensivelytested on real samples containing predominantly pesticides at differentconcentration levels and with matrix effects. Overall, the model wasable to obtain a TPr above 88.8% with FD rates between 33 and 79%and reduction rates between 9 and 45%. Finally, the CNL model wascompared with the retention time difference method and peak shapecorrelation analysis, showing that a combination of correlation analysisand the CNL model was the most effective for fragment deconvolution,obtaining a TPr of 84.7%, an FDr of 54.4%, and a reduction rate of51.0%.
引用
收藏
页码:12247 / 12255
页数:9
相关论文
共 50 条
  • [31] High-resolution capillary isoelectric focusing-electrospray ionization mass spectrometry for hemoglobin variants analysis
    Tang, Q
    Harrata, AK
    Lee, CS
    ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2482 - 2487
  • [32] Speciation and determination of iron in aqueous solution and river water by high-resolution electrospray ionization mass spectrometry
    Okabe, Shunya
    Oda, Kyohei
    Muto, Miu
    Sahoo, Yu Vin
    Tanaka, Miho
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 329
  • [33] Deconvolution of combinatorial oligonucleotide libraries by electrospray ionization tandem mass spectrometry
    Pomerantz, SC
    McCloskey, JA
    Tarasow, TM
    Eaton, BE
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (17) : 3861 - 3867
  • [34] Potential of desorption electrospray ionization and paper spray ionization with high-resolution mass spectrometry for the screening of sports doping agents in urine
    Bressan, Claudia
    Sero, Raquel
    Alechaga, Elida
    Monfort, Nuria
    Moyano, Encarnacion
    Ventura, Rosa
    ANALYTICAL METHODS, 2023, 15 (04) : 462 - 471
  • [35] Negative ion electrospray high-resolution tandem mass spectrometry of polyphenols
    Schmidt, Juergen
    JOURNAL OF MASS SPECTROMETRY, 2016, 51 (01): : 33 - 43
  • [36] Two-dimensional separations with electrospray ionization ambient pressure high-resolution ion mobility spectrometry/quadrupole mass spectrometry
    Matz, LM
    Asbury, GR
    Hill, HH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (07) : 670 - 675
  • [37] Specification of complex-PAHs in coal fire sponges (CFS) by high-resolution mass spectrometry with electrospray ionization
    Xu, Dandan
    Liang, Yanci
    Hong, Xiuping
    Liang, Ming
    Liang, Handong
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (25) : 32754 - 32762
  • [38] Fragmentation patterns of boron-dipyrromethene (BODIPY) dyes by electrospray ionization high-resolution tandem mass spectrometry
    Qi, Yulin
    Geib, Timon
    Anh-Minh Huynh
    Jung, Gregor
    Volmer, Dietrich A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (09) : 885 - 890
  • [39] Application of Secondary Electrospray Ionization Coupled with High-Resolution Mass Spectrometry in Chemical Characterization of Thermally Generated Aerosols
    Zivkovic Semren, Tanja
    Majeed, Shoaib
    Fatarova, Maria
    Laszlo, Csaba
    Pak, Claudius
    Steiner, Sandro
    Vidal-De-Miguel, Guillermo
    Kuczaj, Arkadiusz
    Mazurov, Anatoly
    Peitsch, Manuel C.
    Ivanov, Nikolai V.
    Hoeng, Julia
    Guy, Philippe A.
    Journal of the American Society for Mass Spectrometry, 2022, 33 (11): : 2147 - 2155
  • [40] Online investigation of lignin depolymerization via reactor-integrated electrospray ionization high-resolution mass spectrometry
    Cui, Cunhao
    Zhu, Linyu
    Ouyang, Jianfeng
    Shen, Yang
    Ren, Hairong
    Yuan, Wenhao
    Zhou, Zhongyue
    Qi, Fei
    APPLICATIONS IN ENERGY AND COMBUSTION SCIENCE, 2022, 10