Finite element analysis criteria for composite steel decking concrete slabs subjected to fire

被引:9
|
作者
Bolina, Fabricio L. [1 ,2 ,3 ]
Rodrigues, Joao Paulo C. [4 ,5 ,6 ]
机构
[1] Univ Vale Rio Sinos Unisinos, Dept Civil Engn, Sao Leopoldo, Brazil
[2] Univ Fed Rio Grande do Sul, Dept Civil Engn, Porto Alegre, Brazil
[3] Univ Coimbra, Dept Civil Engn, Coimbra, Portugal
[4] Univ Coimbra, Dept Civil Engn, CERIS, Coimbra, Portugal
[5] Itecons, Coimbra, Portugal
[6] Univ Fed Minas Gerais, Dept Struct Engn, Belo Horizonte, Brazil
关键词
Steel decking; Concrete; Slab; Experimental tests; Numerical simulations; THERMAL-PROPERTIES; BEHAVIOR; FLOORS;
D O I
10.1016/j.firesaf.2023.103818
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In composite steel decking concrete slabs, fire design has to be made according to EN 1994-1-2. However, its procedures are questionable by many references. This is due to the divergence between full-scale experimental research methodologies and numerical studies with different analysis criteria, producing different conclusions. This research sought to numerically study the fire performance of composite steel decking concrete slabs ac-cording to two criteria (C): C1, assuming the same temperature field in the cross section, corresponding to a pre-defined ISO 834 fire rating of 30, 45, 60, 90, 120, 150 and 180 min, and an applied load increasing over time; and C2, assuming the increasing temperature field (slab is heated following ISO 834 fire curve) and a constant load over time applied to the slab. C1 allows to define the ultimate load for each pre-defined time of ISO 834 fire curve, while C2 the thermo-physical-mechanical effects. For the parametric calibration of the numerical models, 12 full-scale slabs were tested. 6 slabs under four-point bending test for mechanical parameter definition. Other 6 slabs for fire testing according to ISO 834 fire curve, for thermal and thermomechanical parameter definition. It was clearly noticed that current requirements of the standard are based on criterion C1, as it presented results that are close to the simple flexural theory. However, C1 does not allow defining increase in stresses produced by heating, which is noted only in C2. In C2 it was possible to identify the concrete cracks and detachment of the decking. In some cases, the concrete stresses produced in C2 were opposite to those shown in C1. It is understood that C2 shows more realistic results, but generates greater complexity and processing time for defining the ul-timate load for each ISO 834 fire curve time.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Finite Element Analysis on Profiled Steel Sheet and Concrete Composite Slab
    Liu, Li
    Yi, Jibin
    Wang, Fang
    ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 500 - +
  • [42] Finite element analysis of fire resistance of steel reinforced concrete frame structures
    Wang G.
    Sun X.
    Zhang D.
    Zheng C.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (02): : 65 - 75
  • [43] Nonlinear Finite Element Analysis of Reinforced Concrete Flat Slabs Subjected to Reversed-Cyclic Loading
    Setiawan, Andri
    Vollum, Robert
    Macorini, Lorenzo
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 814 - 822
  • [44] Experimental and numerical studies on concrete encased embossments of steel strips under shear action for composite slabs with profiled steel decking
    Seres, Noemi
    Dunai, Laszlo
    STEEL AND COMPOSITE STRUCTURES, 2011, 11 (01): : 39 - 58
  • [45] Finite Element Analysis of Steel-concrete Composite Slab with Section Steel Ribs
    Zhang Xiaopeng
    Wang Tiecheng
    CIVIL ENGINEERING IN CHINA - CURRENT PRACTICE AND RESEARCH REPORT, 2010, : 243 - 246
  • [46] Thermal-elastic-plastic finite element analysis for fire behaviors of unbonded prestressed concrete slabs
    Gao, Litang
    Chen, Ligang
    Li, Xiaodong
    Dong, Yuli
    Yingyong Lixue Xuebao/Chinese Journal of Applied Mechanics, 2007, 24 (03): : 490 - 493
  • [47] Thermal-structural analysis of composite slabs with profiled steel decking using shell elements
    Jiang J.
    Cai W.
    Chen W.
    Ye J.
    Li G.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 : 31 - 40
  • [48] NONLINEAR FINITE ELEMENT ANALYSIS OF INSULATED FRP STRENGTHENED REINFORCED CONCRETE COLUMNS SUBJECTED TO FIRE
    El-Mahdy, Osama
    Hamdy, Gehan
    Hisham, Mohamed
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2018, 27 (02):
  • [49] Computational analysis of reinforced concrete structures subjected to fire using a multilayered finite element formulation
    Sosso, Batoma
    Gutierrez, Fabian M. Paz
    Berke, Peter Z.
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (15) : 3488 - 3506
  • [50] MECHANICAL SIMULATION OF REINFORCED CONCRETE SLABS SUBJECTED TO FIRE
    Bacinskas, Darius
    Kaklauskas, Gintaris
    Gribniak, Viktor
    Geda, Edgaras
    TECHNOLOGICAL AND ECONOMIC DEVELOPMENT OF ECONOMY, 2007, 13 (04) : 295 - 302