Detection of Kidney Complications Relevant Concentrations of Ammonia Gas Using Plasmonic Biosensors: A Review

被引:8
|
作者
Usman, Fahad [1 ,2 ]
Ghazali, Kamarul Hawari [1 ,3 ]
Muda, Razali [1 ,3 ]
Dennis, John Ojur [4 ]
Ibnaouf, Khalid Hassan [5 ]
Aldaghri, Osamah A. [5 ]
Alsadig, Ahmed [6 ]
Johari, Nasrul Hadi [1 ,7 ]
Jose, Rajan [8 ,9 ]
机构
[1] Univ Malaysia Pahang, Ctr Adv Ind Technol, Pekan Campus, Pekan 26600, Pahang, Malaysia
[2] Al Qalam Univ Katsina, Dept Phys, PMB 2137, Katsina 820102, Nigeria
[3] Univ Malaysia Pahang, Fac Elect & Elect Engn, Pekan Campus, Pekan 26600, Pahang, Malaysia
[4] Univ Teknol PETRONAS, Dept Fundamental & Appl Sci, Perak 32610, Malaysia
[5] Imam Mohammad Ibn Saud Islamic Univ IMSIU, Coll Sci, Phys Dept, Riyadh 13318, Saudi Arabia
[6] Univ Campus Ecotekne, CNR Nanotec, I-73100 Lecce, Italy
[7] Univ Malaysia Pahang, Fac Mech & Automot Engn Technol, Pekan Campus, Pekan 26600, Pahang, Malaysia
[8] Univ Malaysia Pahang, Ctr Adv Intelligent Mat, Kuantan 26300, Pahang, Malaysia
[9] Univ Malaysia Pahang, Fac Ind Sci & Technol, Kuantan 26300, Pahang, Malaysia
关键词
chronic kidney disease; ammonia biosensor; plasmonic sensors; kidney failure; non-invasive detection; blood urine nitrogen; EXHALED BREATH ANALYSIS; SILVER NANOPARTICLES; OPTICAL-PROPERTIES; GREEN SYNTHESIS; SENSOR; RESONANCE; PERFORMANCE; FABRICATION; DISEASE; NANOCOMPOSITE;
D O I
10.3390/chemosensors11020119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Kidney-related health problems cause millions of deaths around the world annually. Fortunately, most kidney problems are curable if detected at the earliest stage. Continuous monitoring of ammonia from exhaled breath is considered as a replacement for the conventional blood-based monitoring of chronic kidney disease (CKD) and kidney failure owing to its cost effectiveness, non-invasiveness, excellent sensitivity, and capabilities for real-time measurement. The detection of ammonia for renal failure requires a biosensor with a detection limit of 1000 ppb (1 ppm). Among biosensors, plasmonic biosensors have attracted considerable research interest due to their potential for ultra-sensitivity, single particle/molecular level detection capability, multiplexing capability, photostability, real-time measurement, label-free measurement, room temperature operation, naked-eye readability, ease of miniaturization via simple sensor chip fabrication, and instrumentation, among other features. In this review, plasmonic sensors for the detection of ammonia gas relevant to kidney problems (LOD <= 1 ppm) are reviewed. In addition, the utilized strategies and surface functionalization for the plasmonic sensor are highlighted. Moreover, the main limitations of the reported sensors are stated for the benefit of future researchers. Finally, the challenges and prospects of plasmonic-based ammonia gas biosensors for potential application in the monitoring and screening of renal (kidney) failure, as well as the endpoint of the dialysis session, are stated.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Real-time ultrasensitive detection of ammonia gas using a compact CRDS spectrometer
    Lee, Jaebeom
    Oh, Myoung-Kyu
    APPLIED OPTICS, 2023, 62 (05) : 1357 - 1363
  • [42] A systematic review on the detection and monitoring of toxic gases using carbon nanotube-based biosensors
    Onyancha, Robert Birundu
    Ukhurebor, Kingsley Eghonghon
    Aigbe, Uyiosa Osagie
    Osibote, Otolorin Adelaja
    Kusuma, Heri Septya
    Darmokoesoemo, Handoko
    Balogun, Vincent Aizebeoje
    SENSING AND BIO-SENSING RESEARCH, 2021, 34
  • [43] Influence of Chlorpyriphos degradation on analytical detection using biosensors: current status review and future aspects
    Tones, M.
    Pozo, K.
    Diaz, V
    ENTRE CIENCIA E INGENIERIA, 2021, 15 (30): : 9 - 21
  • [44] Infected and Noninfected Diseases Detection for Human Health Using Surface Plasmon Resonance Biosensors: A Review
    Kumar, Rajeev
    Singh, Lokendra
    Malathi, S.
    IEEE SENSORS JOURNAL, 2025, 25 (07) : 10556 - 10565
  • [45] Inhalant abuse and detection using Gas Chromatography: A review literature
    Kaur, Amandeep
    Yadav, Praveen Kumar
    Bumbrah, Gurvinder Singh
    Sharma, Rakesh Mohan
    ANIL AGGRAWALS INTERNET JOURNAL OF FORENSIC MEDICINE AND TOXICOLOGY, 2019, 20 (02)
  • [46] Detection of nerve agents using proton transfer reaction mass spectrometry with ammonia as reagent gas
    Ringer, Joachim M.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2013, 19 (03) : 175 - 185
  • [47] GAS CHROMATOGRAPHIC ANALYSIS OF AROMATIC HYDROCARBONS AT ATMOSPHERIC CONCENTRATIONS USING FLAME IONIZATION DETECTION
    ALTSHULLER, AP
    CLEMONS, CA
    ANALYTICAL CHEMISTRY, 1962, 34 (04) : 466 - +
  • [48] Electrochemical detection and isolation of cancer cells using nano-materials based biosensors-A review
    Nagarajan, Ramila D.
    Kavitha, Jeyam
    Sundramoorthy, Ashok K.
    Atchudan, Raji
    Arya, Sandeep
    Kamalasekaran, Kavitha
    Khosla, Ajit
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (07):
  • [49] Review of optical detection of single molecules beyond the diffraction and diffusion limit using plasmonic nanostructures
    Karim, Farzia
    Smith, Todd B.
    Zhao, Chenglong
    JOURNAL OF NANOPHOTONICS, 2018, 12 (01)
  • [50] Selective detection of part per billion concentrations of ammonia using a p-n semiconducting oxide heterostructure
    Sun, Chenhu
    Dutta, Prabir K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 226 : 156 - 169