Equations for estimating the static supportive torque provided by upper-limb exoskeletons

被引:5
|
作者
Watterworth, Michael W. B. [1 ]
Dharmaputra, Ryuta [1 ]
Porto, Ryan [2 ]
La Delfa, Nicholas J. [1 ]
Cort, Joel A. [3 ]
机构
[1] Ontario Tech Univ, Oshawa, ON, Canada
[2] Gen Motors Co, Global Ergon Lab, Mfg Engn, Detroit, MI USA
[3] Univ Windsor, Windsor, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Exoskeleton; Dynamometry; Reliability; RELIABILITY;
D O I
10.1016/j.apergo.2023.104092
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Upper-limb exoskeletons are gaining traction in industrial work environments. However, other than advertised general specifications (e.g., peak support angle), the support torque provided throughout the reach envelope is largely unknown to end users. As such, this paper describes a methodology for measuring the specific supportive torque provided by upper-limb exoskeletons. The support of four commercially available passive upper-limb exoskeletons was quantified using an isokinetic dynamometer for all support ranges and levels (n = 68). Tests were repeated four times to determine between-session reliability. Intraclass correlation coefficients demonstrated 'Good' to 'Excellent' reliability, except for one condition. Polynomial regression equations were developed for each condition to predict exoskeleton support for any upper-limb elevation angle between 10 degrees and 180 degrees. These equations can be used to approximate upper-limb exoskeleton support in digital human modeling assessments, or to aid selection of exoskeleton settings specific to a worker's anthropometry and work task location.
引用
收藏
页数:12
相关论文
共 49 条
  • [31] Extracting Human-Exoskeleton Interaction Torque for Cable-Driven Upper-Limb Exoskeleton Equipped With Torque Sensors
    Wang, Yansong
    Zahedi, Ahmad
    Zhao, Yanzheng
    Zhang, Dingguo
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2022, 27 (06) : 4269 - 4280
  • [32] Upper-Limb Isometric Force Feasible Set: Evaluation of Joint Torque-Based Models
    Rezzoug, Nasser
    Hernandez, Vincent
    Gorce, Philippe
    BIOMECHANICS, 2021, 1 (01): : 102 - 117
  • [33] Evaluation of antigravitational support levels provided by a passive upper-limb occupational exoskeleton in repetitive arm movements
    Ramella, Giulia
    Grazi, Lorenzo
    Giovacchini, Francesco
    Trigili, Emilio
    Vitiello, Nicola
    Crea, Simona
    APPLIED ERGONOMICS, 2024, 117
  • [34] Investigation of the EEG Scalp Distribution for Estimation of Shoulder Joint Torque in the Upper-Limb Power Assistant System
    Liang, Hongbo
    Zhu, Chi
    Yoshioka, Masataka
    Ueda, Naoya
    Tian, Ye
    Iwata, Yu
    Yu, Haoyong
    Yan, Yuling
    Duan, Feng
    2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2016, : 1912 - 1917
  • [35] Evaluation of two upper-limb exoskeletons during overhead work: influence of exoskeleton design and load on muscular adaptations and balance regulation
    K. Desbrosses
    M. Schwartz
    J. Theurel
    European Journal of Applied Physiology, 2021, 121 : 2811 - 2823
  • [36] Evaluation of two upper-limb exoskeletons during overhead work: influence of exoskeleton design and load on muscular adaptations and balance regulation
    Desbrosses, K.
    Schwartz, M.
    Theurel, J.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (10) : 2811 - 2823
  • [38] sEMG-Based Torque Estimation Using Time-Delay ANN for Control of an Upper-Limb Rehabilitation Robot
    Wang, Chen
    Peng, Liang
    Hou, Zeng-Guang
    Luo, Lincong
    Chen, Sheng
    Wang, Weiqun
    2018 IEEE INTERNATIONAL CONFERENCE ON CYBORG AND BIONIC SYSTEMS (CBS), 2018, : 585 - 591
  • [39] Integrating Compliant Actuator and Torque Limiter Mechanism for Safe Home-Based Upper-Limb Rehabilitation Device Design
    Zhang, Songyuan
    Guo, Shuxiang
    Fu, Yili
    Boulardot, Luc
    Huang, Qiang
    Hirata, Hideyuki
    Ishihara, Hidenori
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (03) : 357 - 364
  • [40] Integrating Compliant Actuator and Torque Limiter Mechanism for Safe Home-Based Upper-Limb Rehabilitation Device Design
    Songyuan Zhang
    Shuxiang Guo
    Yili Fu
    Luc Boulardot
    Qiang Huang
    Hideyuki Hirata
    Hidenori Ishihara
    Journal of Medical and Biological Engineering, 2017, 37 : 357 - 364