Application effect of low-dose spiral CT on pulmonary nodules and its diagnostic value for benign and malignant nodules

被引:0
|
作者
Zheng, Chengquan [1 ]
Wang, Haofeng [1 ]
Liu, Qiaozheng [1 ]
Han, Dong [1 ]
Xin, Yufei [1 ]
Lu, Weina [1 ]
Yan, Zhenchong [1 ]
机构
[1] Julu Cty Hosp, Dept Radiol, 163 Jiankang East Rd, Xingtai 055250, Hebei, Peoples R China
来源
关键词
Low -dose spiral CT; pulmonary nodules; benign and malignant nodules; diagnostic value; LUNG-CANCER; CHILDREN; QUALITY;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: This study was designed to determine the application effect of low-dose computed tomography (LDCT) on detecting pulmonary nodules (PNs) and its diagnostic value for benign and malignant pulmonary nodules. Methods: Data of 432 patients with PNs admitted to Julu County Hospital between March 2018 and June 2021 in were collected and analysed retrospectively. All patients underwent LDCT and conventional-dose spiral computed tomography (CT). The detection rate and image characteristics of the two methods were compared, and the image quality and radiation dose of the two diagnostic methods were also compared. Results: No significant difference was found between LDCT and conventional-dose spiral CT in the detection rate of lung cancer (P > 0.05). The area under the curve of conventional-dose CT was 0.932, with a specificity and sensitivity of 93.87% and 92.45%, and the area under the curve of LDCT was 0.902, with a specificity and sensitivity of 90.80% and 89.62%. The radiation dose consumed during LDCT was greatly less than that consumed by conventional-dose CT (P < 0.05). Additionally, the two methods were not different in CT image quality and superior vena cava artifact (P > 0.05). No notable difference was found between LDCT and conventional-dose CT in terms of the diagnosis rate of PNs in vascular aggregation sign, pleural indentation sign, lobulation sign and spiculation sign. Conclusion: LDCT can clearly show the typical images of early lung cancer, with less effective radiation dose, and can thus contribute to a high detection rate, so it is worth popularizing.
引用
收藏
页码:256 / 263
页数:8
相关论文
共 50 条
  • [41] Fast classification of benign and malignant solitary pulmonary nodules in CT image
    Liu, Lu
    Liu, Wan-Yu
    Chu, Chun-Yu
    Wu, Jun
    Zhou, Yang
    Zhang, Hong-Xia
    Bao, Jie
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (08): : 2060 - 2068
  • [42] Application Potential of Radiomics based on the Unenhanced CT Image for the Identification of Benign or Malignant Pulmonary Nodules
    Zhang, Ling
    Zeng, Bingliang
    Liu, Jiaqi
    Lin, Huashan
    Lei, Pinggui
    Fan, Bing
    Xu, Rong
    CURRENT MEDICAL IMAGING, 2024, 20
  • [43] Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules
    Liu, Jieke
    Xu, Hao
    Qing, Haomiao
    Li, Yong
    Yang, Xi
    He, Changjiu
    Ren, Jing
    Zhou, Peng
    FRONTIERS IN ONCOLOGY, 2021, 10
  • [44] Radiomics analysis of pulmonary nodules in low-dose CT for early detection of lung cancer
    Choi, Wookjin
    Oh, Jung Hun
    Riyahi, Sadegh
    Liu, Chia-Ju
    Jiang, Feng
    Chen, Wengen
    White, Charles
    Rimner, Andreas
    Mechalakos, James G.
    Deasy, Joseph O.
    Lu, Wei
    MEDICAL PHYSICS, 2018, 45 (04) : 1537 - 1549
  • [45] Difference in microvascular structure between benign and malignant pulmonary nodules and its relationship with CT enhancement
    刘士远
    杨春山
    李慎江
    顾倩
    肖湘生
    冯云
    李成洲
    李惠民
    李玉莉
    刘会敏
    Journal of Medical Colleges of PLA, 2006, (04) : 243 - 248
  • [46] Volume quantitation of small pulmonary nodules on low-dose chest CT: A phantom study
    Ko, JP
    Rusinek, H
    Chandra, R
    McGuinness, G
    Betke, M
    Naidich, DP
    RADIOLOGY, 2001, 221 : 312 - 312
  • [47] Comparison of the Value of Color Doppler Ultrasound and Multislice Spiral CT in the Differential Diagnosis of Benign and Malignant Nodules in the Liver
    Jia, Peiwan
    Liu, Ruirong
    Liu, Yun
    Wu, Yanyan
    Dou, Ting
    CONTRAST MEDIA & MOLECULAR IMAGING, 2022, 2022
  • [48] Diagnostic performance of PET/CT in differentiation of malignant and benign non-solid solitary pulmonary nodules
    Yukio Tsushima
    Ukihide Tateishi
    Hajime Uno
    Masahiro Takeuchi
    Takashi Terauchi
    Tomoyuki Goya
    Edmund E. Kim
    Annals of Nuclear Medicine, 2008, 22 : 571 - 577
  • [49] A Gene Expression Classifier from Whole Blood Distinguishes Benign from Malignant Lung Nodules Detected by Low-Dose CT
    Kossenkov, Andrew, V
    Qureshi, Rehman
    Dawany, Noor B.
    Wickramasinghe, Jayamanna
    Liu, Qin
    Majumdar, R. Sonali
    Chang, Celia
    Widura, Sandy
    Kumar, Trisha
    Horng, Wen-Hwai
    Konnisto, Eric
    Criner, Gerard
    Tsay, Jun-Chieh J.
    Pass, Harvey
    Yendamuri, Sai
    Vachanis, Anil
    Bauer, Thomas
    Nam, Brian
    Rom, William N.
    Showe, Michael K.
    Showe, Louise C.
    CANCER RESEARCH, 2019, 79 (01) : 263 - 273
  • [50] Low-dose CT screening for lung cancer: HRCT findings, clinical outcome and CAD schemes in benign versus malignant nodules
    Li, F
    Sone, S
    Abe, H
    MacMahon, HM
    Li, Q
    Doi, K
    RADIOLOGY, 2002, 225 : 148 - 148