Impact of HVAC Operation and Air Distribution Schemes on Thermal Comfort and Energy Consumption in Intermittent High-Occupancy Buildings: A Case of Mosques

被引:4
|
作者
Samiuddin, Syed [1 ]
Budaiwi, Ismail M. [2 ]
Mohammed, Mohammed Alhaji [2 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Prep Engn Technol, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Dept Architectural Engn, Dhahran 31261, Saudi Arabia
关键词
Energy consumption; Thermal comfort; Heating; ventilating; and air-conditioning operation; Intermittent operation; Mosque; COMPUTATIONAL FLUID-DYNAMICS; DISTRIBUTION-SYSTEMS; VENTILATION SYSTEM; LECTURE THEATER; PERFORMANCE; SIMULATION; QUALITY; EFFICIENCY; ROOM; STRATEGIES;
D O I
10.1061/JAEIED.AEENG-1451
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In high-occupancy intermittent buildings, such as mosques and theaters, it is challenging to design proper air distribution systems and HVAC (heating, ventilating, and air-conditioning) operation strategies to maintain thermal comfort at reduced energy consumption. This study investigates the thermal and energy performance of a high-occupancy intermittently operated mosque in Saudi Arabia. DesignBuilder software (version v4.7) was used for the coupled energy and computational fluid dynamics simulations. The continuous HVAC operation results indicate an annual cooling energy consumption of 181 kW center dot h/m(2), with only two under-floor air distribution system models [through-wall supply with eight diffusers at 3 m height and ceiling return (M5) and through-wall supply with 10 diffusers at 3 m height and wall return at 3 m from the ground (M6)] achieving thermal comfort with only a few cold spots in the throw areas. The intermittent operation saved 30% of the total annual energy consumption, reducing it from 181 to 127 kW center dot h/m(2), in turn, saving 35% of the total cooling energy consumption. Intermittent HVAC operation cases achieved thermal comfort, except for the four-way ceiling supply and wall return (M1). Therefore, implementing intermittent HVAC operation strategies in high-occupancy buildings significantly reduces energy consumption, while achieving thermal comfort when appropriate air distribution strategies are employed. These results provide critical guidelines for the design and operation of proper HVAC systems.
引用
收藏
页数:15
相关论文
共 39 条
  • [31] Impact of control loop performance on energy use, air quality, and thermal comfort in building systems with advanced sequences of operation
    Haleem, Shadi M. Abdel
    Pavlak, Gregory S.
    Bahnfleth, William P.
    AUTOMATION IN CONSTRUCTION, 2021, 130
  • [32] High velocity seawater air-conditioning with thermal energy storage and its operation with intermittent renewable energies
    Hunt, Julian David
    Zakeri, Behnam
    Nascimento, Andreas
    Garnier, Bruno
    Pereira, Marcio Giannini
    Bellezoni, Rodrigo Augusto
    de Assis Brasil Weber, Natalia
    Schneider, Paulo Smith
    Machado, Pedro Paulo Bezerra
    Ramos, Dorel Soares
    ENERGY EFFICIENCY, 2020, 13 (08) : 1825 - 1840
  • [33] High velocity seawater air-conditioning with thermal energy storage and its operation with intermittent renewable energies
    Julian David Hunt
    Behnam Zakeri
    Andreas Nascimento
    Bruno Garnier
    Márcio Giannini Pereira
    Rodrigo Augusto Bellezoni
    Natália de Assis Brasil Weber
    Paulo Smith Schneider
    Pedro Paulo Bezerra Machado
    Dorel Soares Ramos
    Energy Efficiency, 2020, 13 : 1825 - 1840
  • [34] On The Influence Of Hydronic Distribution Loop On Energy Performance And Indoor Thermal Comfort For Air-to-water Heat Pump Systems In Residential Buildings
    Dongellini, Matteo
    Piazzi, Agostino
    Morini, Gian Luca
    74TH ATI NATIONAL CONGRESS: ENERGY CONVERSION: RESEARCH, INNOVATION AND DEVELOPMENT FOR INDUSTRY AND TERRITORIES, 2019, 2191
  • [35] Integrated performance optimization of industrial buildings in relation to thermal comfort and energy consumption: A case study in hot summer and cold winter climate
    Zhou, Bailing
    Wang, Dong
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 46
  • [36] Research on thermal comfort and energy efficiency in office buildings with high window-to-wall ratios: a case study in Qingdao
    Hao, Weihao
    Sohn, Dong-Wook
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 2309 - 2327
  • [37] Materials consumption, indoor thermal comfort and associated energy flows of urban residential buildings Case studies from the cold climate zone of China
    Peng, Zhen
    Deng, Wu
    Hong, Yuanda
    INTERNATIONAL JOURNAL OF BUILDING PATHOLOGY AND ADAPTATION, 2019, 37 (05) : 579 - 596
  • [38] Analyzing the cooling effect, thermal comfort, and energy consumption of integrated arrangement of high-rise buildings and green spaces on urban heat island
    Kim, Juui
    Yeom, Seungkeun
    Hong, Taehoon
    SUSTAINABLE CITIES AND SOCIETY, 2025, 119
  • [39] Energy Consumption and Outdoor Thermal Comfort Characteristics in High-Density Urban Areas Based on Local Climate Zone-A Case Study of Changsha, China
    Chen, Yaping
    Wang, Chun
    Hu, Yinze
    SUSTAINABILITY, 2024, 16 (16)