A semi-automated robotic system for percutaneous interventions

被引:1
|
作者
Siegfarth, Marius [1 ]
Lutz, Raffael [1 ]
Iseke, Nils-Christian [1 ]
Moviglia, Javier [1 ]
Sadi, Fabian [1 ]
Stallkamp, Jan [1 ]
机构
[1] Heidelberg Univ, Mannheim Inst Intelligent Syst Med, Mannheim, Germany
关键词
Medical robotics; Interventional radiology; CT robot; Percutaneous intervention; CT;
D O I
10.1007/s11548-023-02882-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeA robotic assistive device is developed for needle-based percutaneous interventions. The aim is a hybrid system using both manual and actuated robotic operation in order to obtain a device that has a large workspace but can still fit in the gantry opening of a CT scanner. This will enable physicians to perform precise and time-efficient CT-guided percutaneous interventions. The concept of the mechanics and software of the device is presented in this work.MethodsThe approach is a semi-automated robotic assistive device, which combines manual and robotic positioning to reduce the number and size of necessary motors. The system consists of a manual rough positioning unit, a robotic fine positioning unit and an optical needle tracking unit. The resulting system has eight degrees of freedom, of which four are manual, which comprise encoders to monitor the position of each axis. The remaining four axes are actuated axes for fine positioning of the needle. Cameras are attached to the mechanical structure for 3D tracking of the needle pose. The software is based on open-source software, mainly ROS2 as robotic middleware, Moveit2 for trajectory calculation and 3D Slicer for needle path planning.ResultsThe communication between the components was successfully tested with a clinical CT scanner. In a first experiment, four needle insertions were planned and the deviation of the actual needle path from the planned path was measured. The mean deviation from the needle path to the target point was 21.9 mm, which is mainly caused both by translational deviation (15.4 mm) and angular deviation (6.8 degrees) of the needle holder. The optical tracking system was able to detect the needle position with a mean deviation of 3.9 mm.ConclusionThe first validation of the system was successful which proves that the proposed concept for both the hardware and software is feasible. In a next step, an automatic position correction based on the optical tracking system will be integrated, which is expected to significantly improve the system accuracy.
引用
收藏
页码:1571 / 1575
页数:5
相关论文
共 50 条
  • [21] Semi-Automated Power Supply Efficiency Measuring System
    Prutianu, Florin
    Ioana-Monica, Pop-Calimanu
    Popescu, Viorel
    2012 10TH INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND TELECOMMUNICATIONS, 2012, : 45 - 48
  • [22] Semi-automated system of silicoflagellate skeleton by personal computer
    Tsutsui, H
    Nishiwaki, N
    Nishida, S
    GIS and Spatial Analysis, Vol 1and 2, 2005, : 1242 - 1247
  • [23] OntoloBridge: A semi-automated ontology update request system
    Turner, John
    Clark, Alex
    McGinty, Hande
    Bunin, Barry
    Schurer, Stephan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [24] Automated and semi-automated map georeferencing
    Burt, James E.
    White, Jeremy
    Allord, Gregory
    Then, Kenneth M.
    Zhu, A-Xing
    CARTOGRAPHY AND GEOGRAPHIC INFORMATION SCIENCE, 2020, 47 (01) : 46 - 66
  • [25] SEMI-AUTOMATED LATENT FINGERPRINT PROCESSING SYSTEM.
    Thornburg, Daryl D.
    Madrazo, Frank G.
    Kentucky University, Office of Research and Engineering Services, Bulletin, 1972, : 9 - 15
  • [26] Design calculations in the development of a semi-automated weaving system
    Elamvazuthi, I
    Nidzam, M
    Sabilan, S
    Kamaruddin, S
    Azmi, MS
    Nazri, A
    SENSORS: ASIASENSE 2003 - ASIAN CONFERENCE ON SENSORS, 2003, : 347 - 351
  • [27] Semi-automated system for measurement of nuchal translucency thickness
    Moratalla, J.
    Pintoffl, K.
    Minekawa, R.
    Lachmann, R.
    Wright, D.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (04) : 412 - 416
  • [28] Trauma Pod: a semi-automated telerobotic surgical system
    Garcia, Pablo
    Rosen, Jacob
    Kapoor, Chetan
    Noakes, Mark
    Elbert, Greg
    Treat, Michael
    Ganous, Tim
    Hanson, Matt
    Manak, Joe
    Hasser, Chris
    Rohler, David
    Satava, Richard
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02): : 136 - 146
  • [29] Evaluation of a semi-automated clinical decision support system
    Dahmke, H.
    Fiumefreddo, R.
    Zaugg, C.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2022, 44 (06) : 1472 - 1472
  • [30] Remote maintenance system for semi-automated manufacturing machines
    Sangregorio, P.
    Cologni, A. L.
    Owen, F. C.
    Previdi, F.
    2015 IEEE 1ST INTERNATIONAL FORUM ON RESEARCH AND TECHNOLOGIES FOR SOCIETY AND INDUSTRY (RTSI 2015) PROCEEDINGS, 2015,