共 45 条
Screw-retained internal connection zirconia CAD-CAM abutments in single implant reconstructions: Results of a 1-year prospective case series study
被引:1
|作者:
del Castillo, Rafael
[1
]
Gutierrez-Garrido, Lourdes
[2
]
Padial-Molina, Miguel
[3
,4
]
Galindo-Moreno, Pablo
[3
,4
]
机构:
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, Rochester, NY USA
[2] Univ Granada, PhD Program Clin Med & Publ Hlth, Granada, Spain
[3] Univ Granada, Sch Dent, Dept Oral Surg & Implant Dent, Granada, Spain
[4] Univ Granada, Inst Invest Biosanitaria, IBS, Granada, Spain
来源:
关键词:
dental implant;
esthetics;
marginal bone level;
monolithic;
outcomes;
single implant restorations;
CONTROLLED CLINICAL-TRIAL;
IN-VITRO EVALUATION;
MARGINAL BONE LOSS;
MEAN FOLLOW-UP;
AESTHETIC COMPLICATIONS;
CUSTOMIZED ZIRCONIA;
TITANIUM ABUTMENTS;
TOOTH RESTORATIONS;
SURVIVAL RATE;
SOFT-TISSUE;
D O I:
10.1111/jopr.13674
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
PurposeTo evaluate the clinical and radiographic outcomes of single-tooth implant restorations using one-piece, internally connected, screw-retained, computer-aided design and computer-aided manufactured monolithic zirconia restorations fabricated on regular diameter implants. Material and methodsFollowing a 2-stage surgical procedure, 22 implants placed in anterior and posterior areas in 21 partially edentulous patients (mean age of 55 years; 9 males/12 females) were evaluated in terms of plaque index, pocket probing depth, bleeding on probing, level of oral hygiene (OH), signs of mucositis/peri-implantitis, esthetic score (ES), gingival zenith position (GZP), papilla index score, the thickness of peri-implant gingiva, radiographic marginal bone loss, and technical complications. Implants and restorations were prospectively followed from the insertion of the restoration (baseline), up to 12-months post-loading. ResultsA 100% implant survival rate resulted after loading; one implant was lost before loading. Clinically, patients performed an adequate OH, and tissues were kept healthy. Probing depth showed a slightly lower value at baseline compared to any follow-up examination (2.26 [0.94] at baseline vs. 2.53 [0.66] mm at 12 months). ES, GZP, and the thickness of the peri-implant gingiva improved throughout the course of the study. Radiographically, average marginal bone level (MBL) was 0.40 (0.40) mm after 1-year follow-up with no differences in average MBL at all time points. Technically, after 1 year of clinical function, neither abutment fracture nor any other serious complications occurred. Hence, prosthetic reconstruction survival rate was 100%. ConclusionsClinical outcomes of single-tooth implant restorations using internally connected, screw-retained, computer-aided design and computer-aided manufacturing monolithic zirconia abutments can be considered a reliable treatment alternative after 1-year clinical observation.
引用
收藏
页码:679 / 688
页数:10