Feasibility and acceptability of continuous glucose monitoring in pregnancy for the diagnosis of gestational diabetes: A single-centre prospective mixed methods study

被引:4
|
作者
Kusinski, Laura C. [1 ]
Brown, Joanne [1 ,2 ]
Hughes, Deborah J. [1 ,2 ]
Meek, Claire L. [1 ,2 ]
机构
[1] Univ Cambridge, Wellcome Trust MRC Inst Metab Sci, Cambridge, England
[2] Cambridge Univ NHS Fdn Trust, Cambridge, England
来源
PLOS ONE | 2023年 / 18卷 / 09期
关键词
WOMEN; TYPE-1;
D O I
10.1371/journal.pone.0292094
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
BackgroundUndiagnosed diabetes in pregnancy is associated with stillbirth and perinatal complications, but standard testing for gestational diabetes using the oral glucose tolerance test (OGTT) is impractical and exacerbates healthcare inequalities. There is an urgent need to improve the accuracy, acceptability and accessibility of glucose testing in pregnancy. We qualitatively assessed the feasibility and acceptability of two alternative home-based methods of glucose testing in pregnant women, using continuous glucose monitoring (CGM), with or without a home-based OGTT.MethodsWe recruited women with a singleton pregnancy at 28 weeks' gestation with >= 1 risk factor for gestational diabetes attending antenatal glucose testing. A Dexcom G6 CGM device was sited and women were asked to take a 75g OGTT solution (Rapilose) on day 4 after an overnight fast. Qualitative interviews were performed with 20 participants using video conferencing according to a semi-structured interview schedule and thematically analysed using NVIVO software.Results92 women were recruited; 73 also underwent a home OGTT. Women had an average of 6.9 days of glucose monitoring and found the CGM painless, easy to use with few or no adverse events. During the qualitative study, the main themes identified were reassurance and convenience. All women interviewed would recommend CGM and a home OGTT for diagnosis of gestational diabetes.ConclusionsCGM with or without a home OGTT is feasible and acceptable to pregnant women for diagnosis of gestational diabetes and offered advantages of convenience and reassurance. Further work is needed to clarify diagnostic thresholds for gestational diabetes using CGM metrics.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Glycated albumin and continuous glucose monitoring metrics across pregnancy in women with pre-gestational diabetes
    Toft, Johanne Holm
    Dalen, Ingvild
    Skadberg, Oyvind
    Goransson, Lasse Gunnar
    Okland, Inger
    Bleskestad, Inger Hjordis
    ENDOCRINOLOGY DIABETES & METABOLISM, 2022, 5 (06)
  • [42] Pilot Study for Use of Intermittently Scanned Continuous Glucose Monitoring in Women with Gestational Diabetes
    O'Malley, Grenye
    Arumugam, Dushyanthy
    Ogyaadu, Selassie
    Levister, Camilla
    Nosova, Emily
    Vieira, Luciana
    Levy, Carol J.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 259 - 261
  • [43] Establishment of pregnancy-specific lipid reference intervals in pregnant women in a single-centre and assessment of the predictive value of early lipids for gestational diabetes mellitus: a prospective cohort study
    Zhao, Dan
    Yuan, Ning
    Sun, Jianbin
    Zhao, Xin
    Zhang, Xiaomei
    ENDOKRYNOLOGIA POLSKA, 2024, 75 (02) : 192 - 198
  • [44] A mixed methods study to explore the feasibility of a novel continuous fetal monitoring device
    Crawford, A.
    Heazell, A.
    Stephens, L.
    Johnstone, E.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 127 - 127
  • [45] Ultrasound diagnosis and outcome of ovarian masses in pregnancy: a single centre prospective study
    Kaur, L.
    Preet, M.
    Kaur, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 71 - 71
  • [46] A PROSPECTIVE SINGLE-CENTRE STUDY OF THE NATURAL HISTORY OF POST-TRANSPLANT ABNORMAL GLUCOSE REGULATION
    Yong, K.
    Nguyen, H.
    Andrea, V.
    Adriana, L.
    Chan, D.
    Dogra, S.
    Lim, W.
    NEPHROLOGY, 2010, 15 : 71 - 72
  • [47] Utility and Acceptability of a Brief Type 2 Diabetes Visual Animation: Mixed Methods Feasibility Study
    Alyami, Mohsen
    Serlachius, Anna
    Law, Mikaela
    Murphy, Rinki
    Almigbal, Turky H.
    Lyndon, Mataroria
    Batais, Mohammed A.
    Algaw, Rawabi K.
    Broadbent, Elizabeth
    JMIR FORMATIVE RESEARCH, 2022, 6 (08)
  • [48] ADEQUACY OF GLYCEMIC CONTROL IN DIABETIC DIALYSIS PATIENTS - A SINGLE CENTRE PROSPECTIVE OBSERVATIONAL STUDY USING CONTINUOUS GLUCOSE MONITORING
    Sharma, S.
    Irvine, D.
    Al-Jumali, T.
    Wijayaratne, K.
    Nama, S.
    Forbes, M.
    Davoren, P.
    Titus, T.
    NEPHROLOGY, 2013, 18 : 68 - 68
  • [49] Acceptability of a virtual prostate cancer survivorship care model in rural Australia: A multi-methods, single-centre feasibility pilot
    Heneka, Nicole
    Chambers, Suzanne K.
    Schaefer, Isabelle
    Carmont, Kelly
    Parcell, Melinda
    Wallis, Shannon
    Walker, Stephen
    Tuffaha, Haitham
    Steele, Michael
    Dunn, Jeff
    AUSTRALIAN JOURNAL OF RURAL HEALTH, 2024, 32 (04) : 815 - 826
  • [50] A Prospective Study on Single Step 75 Grams Oral Glucose Tolerance Test for Screening and Diagnosis of Gestational Diabetes Mellitus and its Fetomaternal Outcome at a Tertiary Care Centre
    Sulochana, Mortha
    Goud, N. Swetha
    Balajojamma, O.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (02): : 751 - 759