Optimization of the "Perth CT" Protocol for Preoperative Planning and Postoperative Evaluation in Total Knee Arthroplasty

被引:0
|
作者
Stojadinovic, Milica [1 ]
Masulovic, Dragan [1 ,2 ]
Kadija, Marko [2 ,3 ]
Milovanovic, Darko [2 ,3 ]
Milic, Natasa [2 ,4 ,5 ]
Markovic, Ksenija [4 ]
Ciraj-Bjelac, Olivera [6 ,7 ]
机构
[1] Univ Clin Ctr Serbia, Ctr Radiol, Pasterova 2, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Med, Belgrade 11000, Serbia
[3] Univ Clin Ctr Serbia, Clin Orthoped Surg & Traumatol, Pasterova 2, Belgrade 11000, Serbia
[4] Univ Clin Ctr Serbia, Inst Med Stat & Informat, Pasterova 2, Belgrade 11000, Serbia
[5] Mayo Clin, Dept Internal Med, Div Nephrol & Hypertens, Rochester, MN 55905 USA
[6] Natl Inst Republ Serbia, Vinca Inst Nucl Sci, Belgrade 11000, Serbia
[7] Univ Belgrade, Fac Elect Engn, Belgrade 11000, Serbia
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 01期
关键词
total knee arthroplasty; Perth CT protocol; optimization; AUTOMATIC EXPOSURE CONTROL; DOSE COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; RADIATION-EXPOSURE; UNITED-STATES; ABDOMINAL CT; REDUCTION; HIP; REPLACEMENT;
D O I
10.3390/medicina60010098
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Total knee arthroplasty (TKA) has become the treatment of choice for advanced osteoarthritis. The aim of this paper was to show the possibilities of optimizing the Perth CT protocol, which is highly effective for preoperative planning and postoperative assessment of alignment. Materials and Methods: The cross-sectional study comprised 16 patients for preoperative planning or postoperative evaluation of TKA. All patients were examined with the standard and optimized Perth CT protocol using advance techniques, including automatic exposure control (AEC), iterative image reconstruction (IR), as well as a single-energy projection-based metal artifact reduction algorithm for eliminating prosthesis artifacts. The effective radiation dose (E) was determined based on the dose report. Imaging quality is determined according to subjective and objective (values of signal to noise ratio (SdNR) and figure of merit (FOM)) criteria. Results: The effective radiation dose with the optimized protocol was significantly lower compared to the standard protocol (p < 0.001), while in patients with the knee prosthesis, E increased significantly less with the optimized protocol compared to the standard protocol. No significant difference was observed in the subjective evaluation of image quality between protocols (p > 0.05). Analyzing the objective criteria for image quality optimized protocols resulted in lower SdNR values and higher FOM values. No significant difference of image quality was determined using the SdNR and FOM as per the specified protocols and parts of extremities, and for the presence of prothesis. Conclusions: Retrospecting the ALARA ('As Low As Reasonably Achievable') principles, it is possible to optimize the Perth CT protocol by reducing the kV and mAs values and by changing the collimation and increasing the pitch factor. Advanced IR techniques were used in both protocols, and AEC was used in the optimized protocol. The effective dose of radiation can be reduced five times, and the image quality will be satisfactory.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] In vivo evaluation of a computer planning system for total knee arthroplasty
    Nofrini, L
    Martelli, S
    Iacono, F
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2004, 73 (01) : 71 - 81
  • [32] Comparison of clinical outcomes between total knee arthroplasty and unicompartmental knee arthroplasty for osteoarthritis of the knee: a retrospective analysis of preoperative and postoperative results
    Horikawa, Akira
    Miyakoshi, Naohisa
    Shimada, Yoichi
    Kodama, Hiroyuki
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [33] Evaluation and validation of 2D biomechanical models of the knee for radiograph-based preoperative planning in total knee arthroplasty
    Asseln, Malte
    Eschweiler, Jorg
    Trepczynski, Adam
    Damm, Philipp
    Radermacher, Klaus
    PLOS ONE, 2020, 15 (01):
  • [34] Preoperative Knee Stiffness and Total Knee Arthroplasty Outcomes
    Winemaker, Mitch
    Rahman, Wael A.
    Petruccelli, Danielle
    de Beer, Justin
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 1437 - 1441
  • [35] A Standardized Protocol for the Treatment of Early Postoperative Stiffness following Total Knee Arthroplasty
    Werner, Steven
    Jacofsky, Marc
    Kocisky, Sarah
    Jacofsky, David
    JOURNAL OF KNEE SURGERY, 2015, 28 (05) : 425 - 427
  • [36] Acupuncture for postoperative pain following total knee arthroplasty: a systematic review protocol
    Jung, Jae-Young
    Cho, Jae-Heung
    Chung, Seok-Hee
    BMJ OPEN, 2015, 5 (11):
  • [37] PHARMACOGENOMICS TESTING FOR POSTOPERATIVE PAIN OPTIMIZATION BEFORE TOTAL KNEE AND TOTAL HIP ARTHROPLASTY
    Awad, Mohamed E.
    Padela, Muhammad Talha
    Sayeed, Zain
    Abaab, Leila
    El-Othmani, Mouhanad M.
    Saleh, Khaled J.
    JBJS REVIEWS, 2018, 6 (10) : E3
  • [38] Effect of both preoperative and postoperative cryoceutical treatment on hemostasis and postoperative pain following total knee arthroplasty
    Desteli, Engin Eren
    Imren, Yunus
    Aydin, Nuri
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (10): : 19150 - 19155
  • [39] Determination of the effect of preoperative knee joint function on postoperative quality of life in patients with total knee arthroplasty
    Kaya, Cigdem
    Seyman, Cigdem Canbolat
    Kaya, Yilmaz
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (10) : 2189 - 2196
  • [40] Correlation between preoperative and postoperative knee kinematics in total knee arthroplasty using cruciate retaining designs
    Seon, Jong Keun
    Park, Ju Kwon
    Jeong, Mun Su
    Jung, Woo Bin
    Park, Kyung Soon
    Yoon, Taek Rim
    Song, Eun Kyoo
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (04) : 515 - 520