Resilience analysis and optimal control of grid-connected converters under unbalanced voltage conditions

被引:3
|
作者
Wang, Qi [1 ]
Yu, Peng [1 ]
Wang, Peng [2 ]
机构
[1] Shanxi Univ, Coll Elect Engn, 92 Wucheng Rd, Taiyuan, Peoples R China
[2] Nanyang Technol Univ, Coll Engn, Singapore, Singapore
关键词
convertors; power electronics; power system control; CURRENT LIMITATION; 3-PHASE INVERTERS; CONTROL STRATEGY; FILTER; MAXIMIZE; SYSTEMS; DESIGN;
D O I
10.1049/pel2.12262
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The operational stability of grid-connected converters is affected by unbalanced grid voltage, which often leads to overcurrent. The traditional control method maintains the grid-into current within the rated limit by adjusting the current reference value. However, this method limits the output active power of the converters and affects their reliability, which can cause active power shortage or even disconnection of the power grid. To deal with this issue, this paper proposes an effective control strategy. First, the interaction between AC and DC sides of the converters under unbalanced voltage conditions is analysed. Second, the resilience is defined and elaborated. Third, considering various constraints such as the grid-into current harmonics, power fluctuations and DC side voltage fluctuations, the operation resilience range of the converters is calculated. Based on the resilience range, an optimal operating point is selected and an optimal strategy is developed. Compared with the traditional strategy, the proposed strategy allows improving the maximum active power output capacity and resilience of the grid-connected converters under unbalanced grid conditions, while simultaneously limiting the power fluctuations and grid-into current distortions within an allowable range. Last, simulation and experimental results show the effectiveness and feasibility of the proposed strategy.
引用
收藏
页码:1765 / 1775
页数:11
相关论文
共 50 条
  • [41] Grid-Connected Control Strategy of VSG under Complex Grid Voltage Conditions
    Zhang B.
    Jin Y.
    Energy Engineering: Journal of the Association of Energy Engineering, 2022, 119 (04): : 1467 - 1482
  • [42] Active Power Decoupling Methods for Three-Phase Grid-Connected Converters Under Unbalanced Grid Conditions
    Zhou, Jiayu
    Tang, Fen
    Xin, Zhen
    Huang, Songwei
    Loh, Poh Chiang
    2017 IEEE 18TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2017,
  • [43] A comparative study of different PLL techniques for synchronization of grid-connected converters under unbalanced and distorted grid conditions
    Saleh, Bassem
    Garmabad, Mahyar
    Wohlfahrt, Thomas
    Paloja, Imer
    Turki, Faical
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [44] Three Reference Frame Control Scheme of 4 wire Grid-connected Inverter for Micro Grid Under Unbalanced Grid Voltage Conditions
    Song, Xianwen
    Wang, Yue
    Hu, Weihao
    Wang, Zhaoan
    APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, : 1301 - 1305
  • [45] Positive- and Negative-Sequence Control of Grid-Connected Photovoltaic Systems under Unbalanced Voltage Conditions
    Mirhosseini, Mitra
    Pou, Josep
    Karanayil, Baburaj
    Agelidis, Vassilios G.
    2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2013,
  • [46] Research on Control Strategy of Three-phase Grid-connected Inverter under Distorted and Unbalanced Voltage Conditions
    Shen, Hong
    Zhang, Ying
    Shi, Yu-long
    Sun, Lei
    Sun, Xiao-feng
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [47] Model Predictive Direct Power Control of Grid-connected Converters Considering Unbalanced Filter Inductance and Grid Conditions
    Yang, Weichen
    Miao, Shihong
    Liu, Zhiwei
    Han, Ji
    Xiong, Yulong
    Tu, Qingyu
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (06) : 1279 - 1288
  • [48] Model Predictive Direct Power Control of Grid-connected Converters Considering Unbalanced Filter Inductance and Grid Conditions
    Weichen Yang
    Shihong Miao
    Zhiwei Liu
    Ji Han
    Yulong Xiong
    Qingyu Tu
    Journal of Modern Power Systems and Clean Energy, 2021, 9 (06) : 1279 - 1288
  • [49] Fault Ride Through Control of Three-phase grid-connected Inverter Under Harmonic and Unbalanced Grid Voltage Conditions
    Guo X.
    Liu W.
    1600, Chinese Society for Electrical Engineering (37): : 5118 - 5124
  • [50] An Enhanced Control Strategy for Three-phase ZVR Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions
    Sun, Guofa
    Hu, Xiaozhen
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 7448 - 7453