The Long-Term Efficacy of Computed Tomography-Navigated Total Hip Arthroplasty: An 18-Year Follow-Up Study

被引:0
|
作者
Imai, Norio [1 ]
Miyasaka, Dai [2 ]
Ibuchi, Shinya [3 ]
Kimura, Keishi [4 ]
Hirano, Yuki [4 ]
Horigome, Yoji [1 ]
Kawashima, Hiroyuki [4 ]
机构
[1] Niigata Univ, Grad Sch Med & Dent Sci, Div Comprehens Musculoskeletal Med, Niigata 9518510, Japan
[2] Niigata Bandai Hosp, Dept Orthoped Surg, Niigata 9500909, Japan
[3] Uonuma Kikan Hosp, Dept Orthoped Surg, Minamiuonuma 9497302, Japan
[4] Niigata Univ, Grad Sch Med & Dent Sci, Dept Regenerat & Transplant Med, Div Orthoped Surg, Niigata 9518510, Japan
关键词
long-term survival; total hip arthroplasty; computed tomography-based navigation system; dislocation; loosening; DISLOCATION; IMPINGEMENT; IMPLANTATION; DIAMETER; RANGE; RISK; STEM;
D O I
10.3390/jcm13051374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Backgroumd: There have been few reports on the long-term survival of computed tomography (CT)-navigated total hip arthroplasty (THA), which should lead to a lower incidence of dislocation and loosening. In this study, we examined survivorship, dislocation, and loosening incidence using plain radiographs over a minimum 15-year follow-up after CT-navigated THA.Methods: We retrospectively reviewed 145 consecutive CT-navigated THAs for >15 years. We surveyed the angles placed in both the acetabular and femoral components, survivorship, the occurrence of dislocation, the revision rate, and the fixation grade of the acetabular component. Results: The mean follow-up duration was 18.4 years. Overall, 73.8% of THAs were within the safe zone of Lewinnek. There were four dislocations (2.8%), with three occurring within 1 month after surgery and the other within 7 years after surgery. Revision THA was performed in one case (0.69%); consequently, the survival rate was 99.3%. The fixation grade was evaluated in 144 hips, and those were evaluated as having "no loosening". Conclusions: CT-navigated THA was speculated to contribute to long-term survivorship, with a low rate of loosening, even after 18 years of follow-up. It was speculated that the acetabular component was placed at an acceptable insertion angle and a suitable position for stable initial fixation.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] LONG-TERM RESULTS OF TOTAL HIP-ARTHROPLASTY IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP - A FOLLOW-UP NOTE
    GARVIN, KL
    BOWEN, MK
    SALVATI, EA
    RANAWAT, CS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (09): : 1348 - 1354
  • [42] Long-Term Stability of Root Coverage of Restored Roots: A 18-Year Follow-up Case Report
    Al-Hamdan, Khalid S.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (11) : ZD10 - ZD13
  • [43] LONG-TERM FOLLOW UP OF CHARNLEY TOTAL HIP-ARTHROPLASTY (THA)
    REFVEM, D
    SKEIE, S
    HARBO, K
    HOGBERG, A
    RAUGSTAD, TS
    BRUGGERANDERSEN, JC
    LICHTENBERG, N
    REVHEIM, K
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02): : 238 - 238
  • [44] Challenges and Long-Term Outcomes of Cementless Total Hip Arthroplasty in Patients Under 30: A 24-Year Follow-Up Study with a Minimum 8-Year Follow-Up, Focused on Developmental Dysplasia of the Hip
    Drobniewski, Marek
    Gonera, Bartosz
    Olewnik, Lukasz
    Borowski, Adam
    Ruzik, Kacper
    Triantafyllou, George
    Borowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
  • [45] CONSTRAINED TOTAL SHOULDER ARTHROPLASTY - LONG-TERM FOLLOW-UP OBSERVATIONS
    POST, M
    JABLON, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (173) : 109 - 116
  • [46] Long-term Follow-up of Patellar Nonresurfacing in Total Knee Arthroplasty
    Choi, Young
    Koo, Junsung
    Moon, Sang Won
    Yang, Younghoon
    Son, Junghwan
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (01) : 49 - 54
  • [47] Souter-strathclyde total elbow arthroplasty - A long-term follow-up study
    Rozing, P
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08): : 1129 - 1134
  • [48] Long-Term Outcomes of Reverse Total Shoulder Arthroplasty A Follow-up of a Previous Study
    Bacle, Guillaume
    Nove-Josserand, Laurent
    Garaud, Pascal
    Walch, Gilles
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (06): : 454 - 461
  • [49] Acetabular fracture: Long-term follow-up and factors associated with secondary implantation of total hip arthroplasty
    Dunet, B.
    Tournier, C.
    Billaud, A.
    Lavoinne, N.
    Fabre, T.
    Durandeau, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (03) : 281 - 290
  • [50] LONG-TERM FOLLOW-UP OF HEPATITIS USING COMPUTED-TOMOGRAPHY
    ISHIKAWA, N
    NAKAGAWA, S
    HIRATA, K
    TAKIZAWA, Y
    HAYASHI, S
    OBARA, T
    ISHIKAWA, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (04) : 645 - 649