共 2 条
A novel technique to quantify bone- to- implant contact of zygomatic implants: a radiographic analysis based on three- dimensional image registration and segmentation
被引:2
|作者:
Gu, Yuwei
[1
,2
,3
,4
,5
,6
,7
]
Zhang, Dingzhong
[8
]
Tao, Baoxin
[1
,2
,3
,4
,5
,6
]
Wang, Feng
[2
,3
,4
,6
,9
]
Chen, Xiaojun
[8
,10
]
Wu, Yiqun
[1
,2
,3
,4
,5
,6
]
机构:
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Dent Ctr & Oral Rehabil 2, Sch Med, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Coll Stomatol, Shanghai, Peoples R China
[3] Chinese Acad Med Sci, Natl Ctr Stomatol, Shanghai, Peoples R China
[4] Chinese Acad Med Sci, Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[5] Chinese Acad Med Sci, Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[6] Chinese Acad Med Sci, Res Unit Oral & Maxillofacial Regenerat Med, Shanghai, Peoples R China
[7] Tongji Univ, Dept Stomatol, Shanghai Peoples Hosp 10, Sch Med, Shanghai, Peoples R China
[8] Shanghai Jiao Tong Univ, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Inst Biomed Mfg & Life Qual Engn, Shanghai, Peoples R China
[9] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Oral Implantol, Sch Med, Shanghai, Peoples R China
[10] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai, Peoples R China
关键词:
Bone- to-implant contact;
zygomatic implants;
atrophic edentulous maxilla;
post-operative radiographic bone- to-implant contact;
CBCT imaging;
COMPUTED-TOMOGRAPHY;
INSERTION;
TISSUES;
LENGTH;
SOFT;
D O I:
10.1259/dmfr.20220210
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Objectives: The purpose of this study is to establish a novel, reproducible technique to obtain the BIC area (BICA) between zygomatic implants and zygomatic bone based on post-operative cone -beam computed tomography (CBCT) images. Three-dimensional (3D) image registration and segmentation were used to eliminate the effect of metal-induced artifacts of zygomatic implants.Methods: An ex -vivo study was included to verify the feasibility of the new method. Then, the radiographic bone - to-implant contact (rBIC) of 143 implants was measured in a total of 50 patients. To obtain the BICA of zygomatic implants and the zygomatic bone, several steps were necessary, including image preprocessing of CBCT scans, identification of the position of zygomatic implants, registration, and segmentation of pre-and post-operative CBCT images, and 3D reconstruction of models. The conventional two-dimensional (2D) linear rBIC (rBIC(c)) measurement method with post-operative CBCT images was chosen as a comparison.Results: The mean values of rBIC and rBIC(c) were 15.08 +/- 5.92 mm and 14.77 +/- 5.14 mm, c respectively. A statistically significant correlation was observed between rBIC and rBIC(c) values (r=0.86,p < 0.0001).Conclusions: This study proposed a standardized, repeatable, noninvasive technique to quan-tify the rBIC of post-operative zygomatic implants in 3D terms. This technique is comparable to conventional 2D linear measurements and seems to be more reliable than these conven-tional measurements; thus, this method could serve as a valuable tool in the performance of clinical research protocols.
引用
收藏
页数:8
相关论文