Three-dimensional analysis of peri-bone-implant contact of rough-surface miniscrew implants

被引:37
|
作者
Ikeda, Hedeki
Rossouw, P. Emile [2 ]
Campbell, Phillip M. [1 ]
Kontogirogos, Elias
Buschange, Peter H. [1 ]
机构
[1] Baylor Coll Dent, Dept Orthodont, Texas A&M Hlth Sci Ctr, Dallas, TX 75246 USA
[2] Univ N Carolina, Dept Orthodont, Chapel Hill, NC USA
关键词
ACID-ETCHED SURFACE; ORTHODONTIC MINI-IMPLANTS; TITANIUM IMPLANTS; TORQUE REMOVAL; MINIATURE PIGS; HISTOMORPHOMETRIC EVALUATION; OSSEOINTEGRATED IMPLANTS; ENDOSSEOUS INTEGRATION; COMPUTED-TOMOGRAPHY; SCREW IMPLANTS;
D O I
10.1016/j.ajodo.2010.09.022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: In this study, we evaluated the effects of surface modifications of miniscrew implants (MSIs) and force application on bone surrounding MSIs. Methods: Seven skeletally mature male foxhound dogs were followed for 9 weeks; a randomized split-mouth design was used to compare 21 MSIs with sandblasted, large-grit, and acid-etched (SLA) surfaces and 21 identical machine-surfaced MSIs. MSIs immediately loaded with 200-g nickel-titanium coil springs were compared with unloaded MSIs. Bone volume to total volume ratios of cortical and noncortical bone regions were measured at 6 to 24 mu m and 24 to 42 mu m from the entire MSI surface using microcomputed tomography with an isotropic resolution of 6 mu m. Results: Clinical success of SLA-surfaced MSIs was 100%, compared with 85.7% for machine-surfaced MSIs. There was significantly (P <0.05) more bone at the coronal aspects of the SLA-surfaced than the machine-surfaced MSIs; the SLAs-urfaced MSIs also showed significantly greater decreases in bone between their most coronal and apical aspects. MSIs that were loaded demonstrated significantly (P <0.05) greater decreases in surrounding bone than unloaded MSIs. The amount of bone within 6 to 24 mu m of the MSIs was significantly less than that within 24 to 42 mu m. Mean placement torque was higher for the SLA-surfaced (42 Ncm) than the machine-surfaced (39 Ncm) MSIs, but the difference was not statistically significant. Conclusions: SLA surface treatment and loadings have significant effects on bone surrounding the MSIs; this might be related to higher success rates and greater secondary stability. (Am J Orthod Dentofacial Orthop 2011;139:e153-e163)
引用
收藏
页码:e153 / e163
页数:11
相关论文
共 50 条
  • [1] Three-dimensional analysis of peribone-implant contact of rough-surface miniscrew implants. (vol 139, pg c153, 2011)
    Ikeda, H.
    Rossouw, P. E.
    Campbell, P. M.
    Kontogiorgos, E.
    Buschang, P. H.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (01) : 4 - 4
  • [2] Three-dimensional evaluation of maxillary anterior alveolar bone for optimal placement of miniscrew implants
    Choi, Jin Hwan
    Yu, Hyung Seog
    Lee, Kee Joon
    Park, Young Chel
    KOREAN JOURNAL OF ORTHODONTICS, 2014, 44 (02) : 54 - 61
  • [3] The effect of force, timing, and location on bone-to-implant contact of miniscrew implants
    Woods, P. W.
    Buschang, P. H.
    Owens, S. E.
    Rossouw, P. E.
    Opperman, L. A.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2009, 31 (03) : 232 - 240
  • [4] Three-dimensional rough surface contact model for anisotropic materials
    He, Ling
    Ovaert, Timothy C.
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2008, 130 (02): : 1 - 6
  • [5] MOVING CONTACT LINES ON A TWO-DIMENSIONAL ROUGH-SURFACE
    JANSONS, KM
    JOURNAL OF FLUID MECHANICS, 1985, 154 (MAY) : 1 - 28
  • [6] CONTACT ANALYSIS OF A SMOOTH BALL ON AN ANISOTROPIC ROUGH-SURFACE
    POON, CY
    SAYLES, RS
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 1994, 116 (04): : 850 - 859
  • [7] A Systematic Review and Meta-Analysis on the Effect of Implant Length on the Survival of Rough-Surface Dental Implants
    Kotsovilis, Sotirios
    Fourmousis, Ioannis
    Karoussis, Ioannis K.
    Bamia, Christina
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (11) : 1700 - 1718
  • [8] A Reconstruction and Contact Analysis Method of Three-Dimensional Rough Surface Based on Ellipsoidal Asperity
    Wen, Yuqin
    Tang, Jinyuan
    Zhou, Wei
    Li, Lin
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2020, 142 (04):
  • [9] Relationship of Three-Dimensional Bone-to-Implant Contact to Primary Implant Stability and Peri-implant Bone Strain in Immediate Loading: Microcomputed Tomographic and In Vitro Analyses
    Hsu, Jui-Ting
    Huang, Heng-Li
    Chang, Chih-Han
    Tsai, Ming-Tzu
    Hung, Wei-Ching
    Fuh, Lih-Jyh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 367 - 374
  • [10] Three-dimensional measurement of radiographic bone-implant contact lengths of zygomatic implants in zygomatic bone: a retrospective study of 66 implants in 28 patients
    Huang, T. -y.
    Hsia, Y. -j.
    Sung, M. -y.
    Wu, Y. -t.
    Hsu, P. -c.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (08) : 1100 - 1106