A clinical and time savings evaluation of a deep learning automatic contouring algorithm

被引:6
|
作者
Ginn, John S. [1 ,4 ]
Gay, Hiram A. [1 ]
Hilliard, Jessica [1 ]
Shah, Jainil [2 ]
Mistry, Nilesh [3 ]
Moehler, Christian [3 ]
Hugo, Geoffrey D. [1 ]
Hao, Yao [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, Sch Med, St Louis, MO 63110 USA
[2] Siemens Healthineers, Cary, NC 27561 USA
[3] Siemens Healthcare GmbH, D-91052 Erlangen, Germany
[4] Washington Univ, Dept Radiat Oncol, Sch Med, 660 S Euclid Ave, St Louis, MO 63110 USA
关键词
Automatic contouring; Deep Learning; Time Savings; Common contouring discrepancies; AUTO-SEGMENTATION; HEAD; DELINEATION; IMAGES; ATLAS; RISK;
D O I
10.1016/j.meddos.2022.11.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Automatic contouring algorithms may streamline clinical workflows by reducing normal organ-at-risk (OAR) contouring time. Here we report the first comprehensive quantitative and qualitative evaluation, along with time savings assessment for a prototype deep learning segmentation algorithm from Siemens Healthineers. The accuracy of contours generated by the prototype were evaluated quantitatively using the Sorensen-Dice coefficient (Dice), Jaccard index (JC), and Hausdorff distance (Haus). Normal pelvic and head and neck OAR contours were evaluated retrospectively comparing the automatic and manual clinical contours in 100 patient cases. Contouring performance outliers were investigated. To quantify the time savings, a certified medical dosimetrist manually contoured de novo and, separately, edited the generated OARs for 10 head and neck and 10 pelvic patients. The automatic, edited, and manually generated contours were visually evaluated and scored by a practicing radiation oncologist on a scale of 1-4, where a higher score indicated better performance. The quantitative comparison revealed high ( > 0.8) Dice and JC performance for relatively large organs such as the lungs, brain, femurs, and kidneys. Smaller elongated structures that had relatively low Dice and JC values tended to have low Hausdorff distances. Poor performing outlier cases revealed common anatomical inconsistencies including overestimation of the bladder and incorrect superior-inferior truncation of the spinal cord and femur contours. In all cases, editing contours was faster than manual contouring with an average time saving of 43.4% or 11.8 minutes per patient. The physician scored 240 structures with > 95% of structures receiving a score of 3 or 4. Of the structures reviewed, only 11 structures needed major revision or to be redone entirely. Our results indicate the evaluated auto-contouring solution has the potential to reduce clinical contouring time. The algorithm's performance is promising, but human review and some editing is required prior to clinical use.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [41] Large scale analysis of the clinical implementation of deep learning contouring in the thorax region
    Vaassen, F.
    Canters, R.
    Lubken, I.
    Mannens, J.
    van Elmpt, W.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S767 - S768
  • [42] Accessible deep learning in the cancer clinic: an open-source, prototype framework for automatic contouring
    Asbach, John
    Singh, Anurag
    Farrugia, Mark
    Matott, L. Shawn
    Le, Anh
    MEDICAL IMAGING 2022: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2022, 12037
  • [43] EVALUATION OF AUTOMATIC CONTOURING METHODS FOR DRAINAGE DESIGN
    KOK, R
    BEGIN, J
    TRANSACTIONS OF THE ASAE, 1981, 24 (01): : 87 - &
  • [44] Automated CTV Contouring for Prostate and Nodes Utilizing Deep Learning Contouring
    Malesevic, V.
    Potters, L.
    Riegel, A. C.
    Cao, Y.
    Baker, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [45] Clinical Evaluation of Deep Learning and Atlas-Based Auto-Contouring of Bladder and Rectum for Prostate Radiation Therapy
    Zabel, W. Jeffrey
    Conway, Jessica L.
    Gladwish, Adam
    Skliarenko, Julia
    Didiodato, Giulio
    Goorts-Matthews, Leah
    Michalak, Adam
    Nakonechny, Keith
    Malkoske, Kyle
    Tran, Muoi N.
    McVicar, Nevin
    PRACTICAL RADIATION ONCOLOGY, 2021, 11 (01) : E80 - E89
  • [46] A Blinded Prospective Evaluation Of Clinical Applicability Of Deep Learning-Based Auto Contouring Of OAR For Head and Neck Radiotherapy
    Blanchard, P.
    Gregoire, V. G.
    Petit, C.
    Milhade, N.
    Allajbej, A.
    Nguyen, T. V. F.
    Bakkar, S.
    Boulle, G.
    Lombard, A.
    Beldjoudi, G.
    Munoz, A.
    Ullman, E.
    Paragios, N.
    Deutsch, E.
    Robert, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E780 - E781
  • [47] Evaluation of measures for assessing automatic OAR delineation acceptability and time-savings
    Vaassen, F.
    Hazelaar, C.
    Vaniqui, A.
    Gooding, M.
    Van der Heyden, B.
    Canters, R.
    Van Elmpt, W.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S955 - S955
  • [48] A deep learning model for automatic evaluation of academic engagement
    Sun, Chen
    Xia, Fan
    Wang, Ye
    Liu, Yan
    Qian, Weining
    Zhou, Aoying
    PROCEEDINGS OF THE FIFTH ANNUAL ACM CONFERENCE ON LEARNING AT SCALE (L@S'18), 2018,
  • [49] An automatic welding defect location algorithm based on deep learning
    Yang, Lei
    Wang, Huaixin
    Huo, Benyan
    Li, Fangyuan
    Liu, Yanhong
    NDT & E INTERNATIONAL, 2021, 120
  • [50] Development of a Deep Learning Algorithm for Automatic Diagnosis of Diabetic Retinopathy
    Raju, Manoj
    Pagidimarri, Venkatesh
    Barreto, Ryan
    Kadam, Amrit
    Kasivajjala, Vamsichandra
    Aswath, Arun
    MEDINFO 2017: PRECISION HEALTHCARE THROUGH INFORMATICS, 2017, 245 : 559 - 563