Future of Time-in-Range Goals in the Era of Advanced Hybrid Closed-Loop Automated Insulin Delivery Systems

被引:11
|
作者
Akturk, Halis K. [1 ]
Battelino, Tadej [2 ,3 ]
Castaneda, Javier [4 ]
Arrieta, Arcelia [4 ]
van den Heuvel, Tim [4 ]
Cohen, Ohad [4 ]
机构
[1] Univ Colorado, Barbara Davis Ctr Diabet, Aurora, CO USA
[2] Univ Ljubljana, Univ Med Ctr Ljubljana, Ljubljana, Slovenia
[3] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[4] Medtron Int Trading Sarl, Route Molliau 31, CH-1131 Tolochenaz, Switzerland
关键词
Automated insulin delivery; Time in tight range; Insulin therapy; Closed-loop; Insulin pump; MiniMed (TM); Glucose control; INTERNATIONAL CONSENSUS; DIABETIC-RETINOPATHY; METRICS; COMPLICATIONS; ASSOCIATION; INITIATION;
D O I
10.1089/dia.2023.0432
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The concept of maintaining blood glucose levels within the 70-180 mg/dL range, known as time-in-range, has raised questions regarding its representation of true physiological euglycemia. Some have speculated that focusing on the time spent within the 70-140 mg/dL range, introduced as time in tight range (TITR) through the International Consensus statement, could serve as a more precise metric for assessing normoglycemia in individuals with type 1 diabetes. This article delves into the current status of TITR as an emerging marker and explores how advanced hybrid closed-loop systems may offer a promising avenue for achieving this higher level of glycemic control.
引用
收藏
页码:102 / 106
页数:5
相关论文
共 50 条
  • [21] Glucose-Responsive Synthetic Closed-Loop Insulin Delivery Systems
    Zhang Yuqi
    Yu Jicheng
    Shen Qundong
    Gu Zhen
    PROGRESS IN CHEMISTRY, 2015, 27 (01) : 11 - 26
  • [22] Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses
    Nimri, Revital
    Grosman, Benyamin
    Roy, Anirban
    Nir, Judith
    Fisch Shvalb, Naama
    Kurtz, Natali
    Loewenthal, Neta
    Gillon-Keren, Michal
    Muller, Ido
    Atlas, Eran
    Phillip, Moshe
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (04) : 268 - 276
  • [23] Closed-loop insulin delivery: current status of diabetes technologies and future prospects
    Majeed, Waseem
    Thabit, Hood
    EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (08) : 579 - 590
  • [24] Real-World Implementation of Hybrid Closed-Loop (HCL) Insulin Delivery
    Faulds, Eileen R.
    Dungan, Kathleen M.
    DIABETES, 2018, 67
  • [25] Minimed 670G: A Hybrid Closed-Loop Insulin Delivery System
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 2016, 58 (1508): : 147 - 148
  • [26] The importance of prandial insulin bolus timing with hybrid closed-loop systems
    Boughton, C. K.
    Hartnell, S.
    Allen, J. M.
    Hovorka, R.
    DIABETIC MEDICINE, 2019, 36 (12) : 1716 - 1717
  • [27] Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy
    Renard, E
    CURRENT OPINION IN PHARMACOLOGY, 2002, 2 (06) : 708 - 716
  • [28] Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system
    Panteleon, Antonios E.
    Loutseiko, Mikhail
    Steil, Garry M.
    Rebrin, Kerstin
    DIABETES, 2006, 55 (07) : 1995 - 2000
  • [29] Experiences of Patients Adopting and Adapting to Closed-Loop Insulin Delivery Systems (CLIDS)
    Manero, Chrystina
    SCIENCE OF DIABETES SELF-MANAGEMENT AND CARE, 2023, 49 (01): : 46 - 54
  • [30] Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes
    Vikash Dadlani
    Jordan E. Pinsker
    Eyal Dassau
    Yogish C. Kudva
    Current Diabetes Reports, 2018, 18