A Generic and Effective System Dispersion Compensation Method: Development and Validation in Visible-Light OCT

被引:1
|
作者
Wang, Jiarui [1 ,6 ]
Xu, Chao [1 ]
Zhu, Shaodi [1 ]
Chen, Defu [2 ]
Qiu, Haixia [3 ]
Lam, Alexander K. N. [4 ]
Leung, Christopher K. S. [4 ]
Yuan, Wu [1 ,5 ]
机构
[1] Chinese Univ Hong Kong, Dept Biomed Engn, Hong Kong 999077, Peoples R China
[2] Beijing Inst Technol, Sch Med Technol, Beijing 100081, Peoples R China
[3] Peoples Liberat Army Gen Hosp, Med Ctr 1, Beijing 100036, Peoples R China
[4] Univ Hong Kong, Dept Ophthalmol, Hong Kong 999077, Peoples R China
[5] Chinese Univ Hong Kong, Shun Hing Inst Adv Engn, Hong Kong 999077, Peoples R China
[6] Zhejiang Lab, Res Ctr Intelligent Sensing, Hangzhou 311100, Peoples R China
基金
美国国家科学基金会;
关键词
visible light; optical coherence tomography; axial resolution; dispersion compensation; material dispersion; OPTICAL COHERENCE TOMOGRAPHY; HIGH-SPEED; ULTRAHIGH-RESOLUTION; DEPENDENT DISPERSION;
D O I
10.3390/photonics10080892
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Compared with optical coherence tomography (OCT) in the near-infrared domain, the visible-light OCT (vis-OCT) system affords a higher axial resolution for discerning subtle pathological changes associated with early diseases. However, the significant material dispersion at the visible-light range leads to a severe problem for dispersion management in vis-OCT systems, which results in a compromised axial resolution. While dispersion compensators (such as prism pairs) are commonly used, a digital method is still highly desirable and has been widely used to compensate for the residual dispersion imbalance between the reference and sample arms in an OCT system. In this paper, we develop a generic approach to effectively compensate for the system dispersion, especially the higher-order dispersion in the vis-OCT system, by using a single arbitrary measurement of the mirror-reflection (SAMMR) method and its resulting phase information. Compared with the previous methods, including the method based on the Taylor series iterative fitting and differential method, the proposed method does not need to extract the dispersion coefficients or use the metric functions and affords a better performance for axial resolution and the signal-to-noise ratio in vis-OCT systems. Its effectiveness is further validated in an OCT system operating in the near-infrared domain.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Detection Ability Mathematical Model and Performance Evaluation Method in Visible-Light Photoelectric Detection System
    Li, Hanshan
    Chen, Sangsang
    IEEE SENSORS JOURNAL, 2017, 17 (06) : 1649 - 1655
  • [32] Heartbeat-induced Ocular Pulsation in the Murine Cornea revealed by PhaseSensitive Visible-Light OCT
    May, Lucas
    Lichtenegger, Antonia
    Patel, Yash
    Varaka, Maria
    Worm, Sybren
    Belekar, Prajakta
    Merkle, Conrad
    Werkmeister, Rene
    Garhoefer, Gerhard
    Baumann, Bernhard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (09)
  • [33] Dynamically measuring retinal oxygen saturation at microvascular level using visible-light OCT angiograph
    Chen, Siyu
    Yi, Ji
    Zhang, Hao F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [34] Visible-Light OCT Captures In-vivo Changes in Retinal Oximetry in Ischemic Retinal Diseases
    Kfir, Jonathan
    Ghassabi, Zeinab
    Wu, Mengfei
    Rubinoff, Ian
    Kuranov, Roman V.
    Wang, Yuanbo
    Davis, Benjamin
    Tayebi, Behnam
    Schuman, Joel
    Zhang, Hao
    Ishikawa, Hiroshi
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (09)
  • [35] Ultrathin visible-light OCT endomicroscopy for in vivo ultrahigh-resolution neuroimaging in deep brain
    Xu, Chao
    Zhang, Tinghua
    Abbasi, Syeda Aimen
    Liu, Peng
    Yan, Bryan P.
    Ng, Sze Hang Calvin
    Yuan, Wu
    APL PHOTONICS, 2024, 9 (11)
  • [36] Intelligent lighting system using visible-light communication technology
    Miki, Mitsunori
    Asayama, Emi
    Hiroyasu, Tomoyuki
    2006 IEEE Conference on Cybernetics and Intelligent Systems, Vols 1 and 2, 2006, : 186 - 191
  • [37] VISIBLE-LIGHT TOMOGRAPHY USING AN OPTICAL IMAGING-SYSTEM
    INGESSON, LC
    KONING, JJ
    DONNE, AJH
    SCHRAM, DC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10): : 5185 - 5187
  • [38] An optimal lights layout scheme for visible-light communication system
    Ding Deqiang
    Ke Xizheng
    Xu Linpeng
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL II, 2007, : 189 - +
  • [39] Efficient Resource Allocation Scheme for Visible-Light Communication System
    Kim, Woo-Chan
    Bae, Chi-Sung
    Cho, Dong-Ho
    Shin, Hong-Seok
    Jung, D. K.
    Oh, Y. J.
    BROADBAND ACCESS COMMUNICATION TECHNOLOGIES III, 2009, 7234
  • [40] A SIMO Hybrid Visible-Light Communication System for Optical IoT
    Teli, Shivani Rajendra
    Chvojka, Petr
    Vitek, Stanislav
    Zvanovec, Stanislav
    Perez-Jimenez, Rafael
    Ghassemlooy, Zabih
    IEEE INTERNET OF THINGS JOURNAL, 2022, 9 (05) : 3548 - 3558