Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery

被引:8
|
作者
Zhao, He [1 ]
Wang, Yan-jun [1 ]
Wang, Rui-guo [2 ]
Liu, Da [3 ]
Duan, Ya-qing [4 ]
Liu, Yang-jin [1 ]
Zeng, Yu-hong [5 ]
Zhao, Qin-peng [2 ]
Zhang, Zheng-ping [2 ,6 ]
机构
[1] Xi An Jiao Tong Univ, Honghui Hosp, Dept Emergency Med, Xian 710054, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Honghui Hosp, Dept Spine Surg, Xian 710054, Shaanxi, Peoples R China
[3] Gen Hosp Western Theatre Command PLA, Dept Orthopaed, Chengdu 610083, Sichuan, Peoples R China
[4] Xi An Jiao Tong Univ, Honghui Hosp, Dept Imaging, Xian 710054, Shaanxi, Peoples R China
[5] Xi An Jiao Tong Univ, Honghui Hosp, Dept Osteoporosis, Xian 710054, Shaanxi, Peoples R China
[6] Xi An Jiao Tong Univ, Honghui Hosp, Dept Spine Surg, 76 Nanguo Rd, Xian 710054, Shaanxi, Peoples R China
关键词
osteoporosis; degenerative spinal disease; fixation failure; imaging observation; BONE-MINERAL DENSITY; CT;
D O I
10.2147/CIA.S389059
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Purpose: Dual-energy X-ray absorptiometry (DXA) is commonly used for evaluation of bone mineral density before spinal surgery, but frequently leads to overestimation in degenerative spinal diseases due to osteoproliferation factors. We introduce a novel method to compare the predictive ability of Hounsfield Units (HU) and DXA methods to predict screw loosening after lumbar interbody fusion surgery in degenerative spinal diseases by measuring HU of pedicle screw trajectory on computed tomography (CT) images preoperatively.Patients and Methods: This retrospective study was conducted on patients who underwent posterior lumbar fusion surgery for degenerative diseases. CT HUs measurement was performed using medical imaging software, including the cancellous region on cross-sections of the vertebral body and three-dimensional pedicle screw trajectory. Receiver operating characteristic (ROC) curve analyses were performed for the risk of pedicle screw loosening in association with the Hounsfield scale and preoperative BMD, and the area under the curve (AUC) and the cutoff values were calculated.Results: A total of 90 patients were enrolled and were divided into loosening (n = 33, 36.7%) and non-loosening groups (n = 57, 63.3%). No significant differences in age, gender, length of fixation and preoperative BMD were found between both groups. The loosening group showed lower CT HU values in the vertebral body and screw trajectory than the non-loosening group. Screw trajectory HU (ST-HU) exhibited a higher AUC value than vertebral body HU (B-HU). The cutoff values of B-HU and ST-HU were 160 and 110 HUs, respectively. Conclusion: Three-dimensional pedicle screw trajectory HU values yields a stronger predictive value than vertebral body HU values and BMD and may provide more guidance for surgery. The risk of screw loosening is significantly increased at ST-HU <110 or B-HU <160 at L5 segment.
引用
收藏
页码:485 / 493
页数:9
相关论文
共 50 条
  • [31] Forearm bone mineral density predicts screw loosening after lumbar fusion similar to lumbar Hounsfield unit value in patients with lumbar spondylolisthesis
    Chen, Qian
    Tu, Zhen
    Ai, Youwei
    Li, Wen
    Chen, Jianwen
    Feng, Junfei
    Deng, Wei
    Wang, Ye
    Jiang, Ping
    OSTEOPOROSIS INTERNATIONAL, 2024, 35 (03) : 543 - 549
  • [32] Forearm bone mineral density predicts screw loosening after lumbar fusion similar to lumbar Hounsfield unit value in patients with lumbar spondylolisthesis
    Qian Chen
    Zhen Tu
    Youwei Ai
    Wen Li
    Jianwen Chen
    Junfei Feng
    Wei Deng
    Ye Wang
    Ping Jiang
    Osteoporosis International, 2024, 35 : 543 - 549
  • [33] Upper Lumbar Pedicle Screw Insertion Using Three-Dimensional Fluoroscopy Navigation: Assessment of Clinical Accuracy
    Sugimoto, Yoshihisa
    Ito, Yasuo
    Tomioka, Masao
    Shimokawa, Tetsuya
    Shiozaki, Yasuyuki
    Mazaki, Tetsuro
    Tanaka, Masato
    ACTA MEDICA OKAYAMA, 2010, 64 (05) : 293 - 297
  • [34] Three-Dimensional Patient-Specific Guides for Intraoperative Navigation for Cortical Screw Trajectory Pedicle Fixation
    Kim, Jiwon
    Rajadurai, Jeremy
    Choy, Wen Jie
    Cassar, Lachlan
    Phan, Kevin
    Harris, Leigh
    Fiechter, Meinrad
    Mobbs, Ralph J.
    WORLD NEUROSURGERY, 2019, 122 : 674 - 679
  • [35] Can insertional torque predict screw loosening and related failures?: An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion
    Okuyama, K
    Abe, E
    Suzuki, T
    Tamura, Y
    Chiba, M
    Sato, K
    SPINE, 2000, 25 (07) : 858 - 864
  • [36] Predictive factors of distal pedicle screw loosening followed posterior corrective surgery for degenerative lumbar scoliosis
    Hongru Yuan
    Yilei Liu
    Chenjie Dai
    Puxin Yang
    Yachong Huo
    Di Zhang
    Hui Wang
    BMC Musculoskeletal Disorders, 26 (1)
  • [37] Early clinical results with cortically based pedicle screw trajectory for fusion of the degenerative lumbar spine
    Glennie, R. Andrew
    Dea, Nicolas
    Kwon, Brian K.
    Street, John T.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (06) : 972 - 975
  • [38] Vertebral Bone Quality Score as a Predictor of Pedicle Screw Loosening Following Surgery for Degenerative Lumbar Disease
    Li, Wenshuai
    Zhu, Houze
    Hua, Zijian
    Miao, Dechao
    Wang, Feng
    Tong, Tong
    Wang, Linfeng
    SPINE, 2023, 48 (23) : 1635 - 1641
  • [39] Pilot study of oblique lumbar interbody fusion using mobile percutaneous pedicle screw and validation by a three-dimensional finite element assessment
    Eguchi, Yawara
    Orita, Sumihisa
    Yamada, Hiroyuki
    Suzuki, Munetaka
    Yamanaka, Hajime
    Tamai, Hiroshi
    Inage, Kazuhide
    Narita, Miyako
    Shiga, Yasuhiro
    Inoue, Masahiro
    Norimoto, Masaki
    Umimura, Tomotaka
    Sato, Takashi
    Suzuki, Masahiro
    Enomoto, Keigo
    Koda, Masao
    Furuya, Takeo
    Maki, Satoshi
    Hirosawa, Naoya
    Aoki, Yasuchika
    Nakamura, Junichi
    Hagiwara, Shigeo
    Akazawa, Tsutomu
    Takahashi, Hiroshi
    Takahashi, Kazuhisa
    Shiko, Yuki
    Kawasaki, Yohei
    Ohtori, Seiji
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 76 : 74 - 80
  • [40] PEDICLE SCREW STIMULATION AND SPONTANEOUS ELECTROMYOGRAPHY MONITORING DURING LUMBAR SPINE FUSION SURGERY
    SHIELDS, CB
    DIMAR, JR
    GLASSMAN, S
    PUNO, RM
    LINDEN, RD
    JOURNAL OF NEUROSURGERY, 1994, 80 (02) : A403 - A404