Clinical evaluation of a decision support system for glucose infusion in hypoglycaemic clamp experiments

被引:0
|
作者
Pavan, Jacopo [1 ]
Herzig, David [2 ,3 ]
Tripyla, Afrodity [2 ,3 ]
Dalla Man, Chiara [1 ]
Bally, Lia [2 ,3 ]
Del Favero, Simone [1 ]
机构
[1] Univ Padua, Dept Informat Engn, Via Gradenigo 6-B, I-35131 Padua, Italy
[2] Bern Univ Hosp, Dept Diabet Endocrinol Nutr Med & Metab, Inselspital, Bern, Switzerland
[3] Univ Bern, Bern, Switzerland
来源
DIABETES OBESITY & METABOLISM | 2023年 / 25卷 / 12期
基金
瑞士国家科学基金会;
关键词
bariatric surgery; clinical trial; glycaemic control; hypoglycaemia; INSULIN;
D O I
10.1111/dom.15265
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To provide a preliminary evaluation of the accuracy and safety of Gluclas decision support system suggestions in a hypoglycaemic clamp study. Methods: This analysis was performed using data from 32 participants (four groups with different glucose-insulin regulation: post Roux-en-Y gastric bypass with and without postprandial hypoglycaemia syndrome, postsleeve gastrectomy and nonoperated controls) undergoing Gluclas-assisted hypoglycaemic clamps (target: 2.5 mmol/L for 20 minutes at 150 minutes after oral glucose ingestion). Gluclas provided glucose infusion rate suggestions upon manual entry of blood glucose values (every 5 minutes), which were either followed or overruled by investigators after critical review. Accuracy and safety were evaluated by mean absolute error (MAE), mean absolute percentage error (MAPE), average glucose level, coefficient of variation (CV) and minimal glucose level during the 20-minute hypoglycaemic period. Results: Investigators accepted 84% of suggestions, with a mean deviation of 30.33 mg/min. During the hypoglycaemic period, the MAE was 0.16 (0.12-0.24) (median [interquartile range]) mmol/L and the MAPE was 6.12% (4.80%-9.29%). CV was 4.90% (3.58%-7.27%), with 5% considered the threshold for sufficient quality. The minimal glucose level was 2.40 (2.30-2.50) mmol/L. Conclusions: Gluclas achieved sufficiently high accuracy with minimal safety risks in a population with differences in glucose-insulin dynamics, underscoring its applicability to various patient groups.
引用
收藏
页码:3709 / 3715
页数:7
相关论文
共 50 条
  • [21] Accuracy of a blood glucose monitoring system at hypoglycaemic glucose levels: analysis of seven clinical studies
    Diago Cabezudo, J.
    Bellary, S.
    Cameron, H.
    MacLeod, K.
    Ellison, J.
    Raja, P.
    DIABETOLOGIA, 2012, 55 : S426 - S426
  • [22] Evaluation of a Clinical Decision Support System for Imaging Requests A Cluster Randomized Clinical Trial
    Dijk, Stijntje W.
    Wollny, Claudia
    Barkhausen, Joerg
    Jansen, Olav
    Mildenberger, Peter
    Halfmann, Moritz C.
    Stroeder, Jonas
    Rizopoulos, Dimitris
    Hunink, M. G. Myriam
    Kroencke, Thomas
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2025,
  • [23] Clinical evaluation of a novel test strip technology for blood glucose monitoring: Accuracy at hypoglycaemic glucose levels
    Bellary, Srikanth
    Cameron, Hillary
    Macleod, Kirsty
    Malecha, Michael
    Koria, Krisna
    Raja, Praveen
    Diago Cabezudo, Jesus
    Ellison, John
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 98 (03) : 430 - 435
  • [24] Personalisable Clinical Decision Support System
    Muller, Tamara
    Lio, Pietro
    ERCIM NEWS, 2019, (116): : 19 - 20
  • [25] A decision support system for housing evaluation
    Natividade-Jesus, E
    Coutinho-Rodrigues, J
    XXX IAHS WORLD CONGRESS ON HOUSING, HOUSING CONSTRUCTION: AN INTERDISCIPLINARY TASK, VOLS 1-3, 2002, : 1329 - 1336
  • [26] PERFORMANCE EVALUATION OF A DECISION SUPPORT SYSTEM
    WHITE, CC
    SAGE, AP
    DOZONO, S
    SCHERER, WT
    LARGE SCALE SYSTEMS IN INFORMATION AND DECISION TECHNOLOGIES, 1984, 6 (01): : 39 - 48
  • [27] Decision support system for bid evaluation
    Ray, PS
    Aggarwal, A
    Moynihan, GP
    Bishop, PB
    INTERNATIONAL JOURNAL OF INDUSTRIAL ENGINEERING-THEORY APPLICATIONS AND PRACTICE, 2005, 12 (03): : 277 - 285
  • [28] Accuracy and performance evaluation of a clinical decision support system for laboratory result alerts
    Cho, InSook
    Kim, SunTae
    Kim, JeongAh
    Ha, Kyu Seob
    Kim, Yoon
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2011, 34 (02) : 171 - 179
  • [29] Development and evaluation of a clinical decision support system for early diagnosis of acute appendicitis
    Shahmoradi, Leila
    Safdari, Reza
    Mirhosseini, Mir Mikail
    Rezayi, Sorayya
    Javaherzadeh, Mojtaba
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] Development and evaluation of a clinical decision support system for early diagnosis of acute appendicitis
    Leila Shahmoradi
    Reza Safdari
    Mir Mikail Mirhosseini
    Sorayya Rezayi
    Mojtaba Javaherzadeh
    Scientific Reports, 13