Time-domain fit for improved contrast in quantitative coherent anti-Stokes Raman spectroscopy

被引:2
|
作者
Lu, Minjian [1 ]
Zhang, Yujia [1 ]
LI, Jiarui [1 ]
LI, Yan [1 ]
Wei, Haoyuan [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
MATRIX PENCIL METHOD; PARAMETERS;
D O I
10.1364/OE.493067
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Among the multiple coherent anti-Stokes Raman scattering (CARS) techniques that provide important quantitative molecular microscopic contrast, Fourier-transform CARS (FT-CARS) stands out with the immunity to nonresonant background and high-speed detection capacity. However, by using FFT for the exponentially decaying signal, FT-CARS faces the dilemma of choosing the delay range of the signal for high SNR or high resolution, the lack of either of which is detrimental to the quantitative contrast of imaging. Here, time-domain fit (TDF) is proposed to fully utilize the time-domain information of FT-CARS, providing optimized SNR and vibrational feature distinguishment. The capacity of noise restriction and feature distinguishment of the traditional FFT and the proposed TDF is analysed with theoretical examination and simulation. Exploiting the matrix pencil extraction of vibrational parameters, TDF is performed for quantitative analysis for simulated FT-CARS signal, and shows more accurate and consistent performance than the FFT method. FT-CARS coupled with TDF intensity evaluation holds the promise to provide micro-spectroscopic contrast with higher SNR and free of spectral overlapping, contributing to a more powerful diagnostic tool.
引用
收藏
页码:25571 / 25584
页数:14
相关论文
共 50 条
  • [41] Real-time monitoring of blood using coherent anti-Stokes Raman spectroscopy
    Dogariu, Arthur
    Goltsov, Alexander
    Scully, Marlan O.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (05)
  • [42] SATURATION AND SECONDARY STOKES EFFECTS IN COHERENT ANTI-STOKES RAMAN-SPECTROSCOPY
    WEIL, H
    SCHREIBER, PW
    APPLIED OPTICS, 1982, 21 (05): : 941 - 948
  • [43] Time-resolved coherent anti-Stokes Raman spectroscopy impulsively excited by supercontinuum
    Xu, Qian
    Shi, Kebin
    Liu, Zhiwen
    JOURNAL OF RAMAN SPECTROSCOPY, 2011, 42 (12) : 2100 - 2104
  • [44] Optimal control of coherent anti-Stokes Raman scattering image contrast
    Bergner, Gero
    Schluecker, Sebastian
    Kampe, Bernd
    Dittrich, Peter
    Dietzek, Benjamin
    Popp, Juergen
    APPLIED PHYSICS LETTERS, 2012, 100 (26)
  • [45] SENSITIVITY OF QUANTITATIVE VIBRATIONAL COHERENT ANTI-STOKES RAMAN-SPECTROSCOPY TO SATURATION AND STARK SHIFTS
    PEALAT, M
    LEFEBVRE, M
    TARAN, JPE
    KELLEY, PL
    PHYSICAL REVIEW A, 1988, 38 (04): : 1948 - 1965
  • [46] Quantum squeezing effects of radiation in Stokes and anti-Stokes modes in coherent anti-Stokes Raman scattering and coherent anti-Stokes hyper-Raman scattering
    Giri, DK
    Gupta, PS
    JOURNAL OF MODERN OPTICS, 2004, 51 (11) : 1705 - 1715
  • [47] Improved temperature precision in rotational coherent anti-Stokes Raman spectroscopy with a modeless dye laser
    Vestin, F
    Afzelius, M
    Bengtsson, PE
    APPLIED OPTICS, 2006, 45 (04) : 744 - 747
  • [48] A Simplified Method of Microscopic Hyperpolarizability of Coherent Anti-Stokes Raman Spectroscopy and Coherent Anti-Stokes Hyper-Raman Spectroscopy-C3v Symmetry
    Wang Yuan
    Zhang Zhen
    Guo Yuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (05) : 1382 - 1387
  • [49] Quantitative analysis of metabolites in urine by anti-Stokes Raman spectroscopy
    Dou, XM
    Yamaguchi, Y
    Yamamoto, H
    Doi, S
    Ozaki, Y
    BIOSPECTROSCOPY, 1997, 3 (02): : 113 - 120
  • [50] SIMULTANEOUS ROTATIONAL COHERENT ANTI-STOKES RAMAN-SPECTROSCOPY AND COHERENT STOKES RAMAN-SPECTROSCOPY WITH ARBITRARY PUMP STOKES SPECTRAL SEPARATION
    ECKBRETH, AC
    ANDERSON, TJ
    OPTICS LETTERS, 1986, 11 (08) : 496 - 498