Thermo-hydraulic performance of double pass solar air heater duct having semi-circular tubes and perforated blocks as artificial roughness

被引:15
|
作者
Hedau, Ankush [1 ]
Saini, R. P. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Hydro & Renewable Energy, Roorkee 247667, India
关键词
Double pass solar air heater; Perforated block; Artificial roughness; Semi-circular tube; Computational fluid dynamics; Thermo-hydraulic performance; TRANSFER ENHANCEMENT; RECTANGULAR DUCT; TRANSVERSE RIBS; CFD ANALYSIS; CHANNEL; FLOW;
D O I
10.1016/j.renene.2023.01.087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar air heaters (SAH) are used to collect and convert the solar radiations into thermal energy for various thermal applications. Its thermo-hydraulic performance can be improved by using various geometries of artificial roughness that breaks the laminar sublayer on absorber plate. In view of the same, a 3-dimensional computa-tional investigation is conducted to study the heat transfer and friction characteristics of a double pass SAH having transverse semi-circular tubes with rectangular perforated blocks as artificial roughness and its outcomes are reported under the present paper. The investigation is carried out for different parameters such as Reynolds number (Re), tube amplitude to duct-height ratio (a/H), relative blockage-height ratio (e/H) and open area ratio (beta) within a range of 3000-19,000, 0.2 to 0.5, 0.4 to 0.8 and 13%-30%, respectively. The results obtained through CFD simulations are also compared with the experimental results for a typical set of parameters and a maximum percentage deviation for Nusselt number and friction factor are found as 1.82% and 5.28% respec-tively. For a considered range of parameters, the maximum value of thermo-hydraulic performance parameter is achieved as 2.51 corresponds to Re of 3000, a/H of 0.3, e/H of 0.4, and beta of 30%. Based on the obtained results, it is found that the perforated blocks having maximum value of beta and minimum value of e/H results in improved thermo-hydraulic performance of a double pass SAH. The research output of the present study may be useful for designing and optimize the parameters of a double pass SAH for the low temperature applications such as space heating, solar drying and solar air conditioning.
引用
收藏
页码:543 / 562
页数:20
相关论文
共 50 条
  • [41] Thermo-hydraulic performance analysis of a solar air heater (SAH) with quarter-circular ribs on the absorber plate: A comparative study
    Mahanand, Yadaba
    Senapati, Jnana Ranjan
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 161
  • [42] Thermo-hydraulic optimization of a solar air heater duct with non-periodic rows of rectangular winglet pairs
    Dezan, Daniel J.
    Rocha, Andre D.
    Salviano, Leandro O.
    Ferreira, Wallace G.
    SOLAR ENERGY, 2020, 207 : 1172 - 1190
  • [43] Numerical Modeling of Thermo-Hydraulic Performance and Enhancement Factors in Solar Air Heaters with Honeycomb Roughness
    Ghanem, Somar Rajeh
    Bhosale, Amit C.
    9TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY, IYCE 2024, 2024,
  • [44] CFD based performance analysis of a solar air heater duct provided with artificial roughness
    Kumar, Sharad
    Saini, R. P.
    RENEWABLE ENERGY, 2009, 34 (05) : 1285 - 1291
  • [45] Optimization and evaluation of thermo-hydraulic performance of solar air heaters equipped with different roughness geometries
    Salarpour, Nakisa
    Azadani, Leila N.
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [46] Effect of roughness parameters on performance of solar air heater having artificial wavy roughness using CFD
    Haldar, Ankur
    Varshney, L.
    Verma, Prashant
    RENEWABLE ENERGY, 2022, 184 : 266 - 279
  • [47] A comparative analysis of thermo-hydraulic performance of a roughened solar air heater using various rib shapes
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Mangrulkar, Chidanand
    AUSTRALIAN JOURNAL OF MECHANICAL ENGINEERING, 2020, 18 (03) : 331 - 350
  • [48] Thermo-hydraulic performance of a solar air heater with staggered C-shape finned absorber plate
    Saravanan, A.
    Murugan, M.
    Reddy, M. Sreenivasa
    Ranjit, P. S.
    Elumalai, P., V
    Kumar, Pramod
    Sree, S. Rama
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 168
  • [49] A review of CFD methodology used in literature for predicting thermo-hydraulic performance of a roughened solar air heater
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Chamoli, Sunil
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 : 550 - 605
  • [50] Thermo-hydraulic performance of roughened solar air heater by design of experiment and meta-heuristic approach
    Kumar, Anup
    Layek, Apurba
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 10 : 92 - 102